background image

Installation

Professional Freestanding Ranges

Summary of Contents for CVGR5304B

Page 1: ...Installation Professional Freestanding Ranges ...

Page 2: ..._______________________________________________________15 Leg Installation ________________________________________________________________16 Leveling Adjustments Alignment ________________________________________________16 Anti tip Device Installation ______________________________________________________18 Connecting Gas Electric ______________________________________________________19 Standoff ...

Page 3: ...e must be installed in the gas supply line to the appliance An air curtain or other overhead range hood which operates by blowing a downward airflow onto the range shall not be used with a gas range Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance ALWAYS read and obey all safety messages This is the safety a...

Page 4: ... receptacle type breaker type or portable type NOT recommended Used with permanent wiring only temporary or portable wiring NOT recommended On a dedicated circuit no other receptacles switches or loads in the circuit Connected to a standard breaker of appropriate size GFI breaker of the same size NOT recommended Rated for Class A 5 mA 1 mA trip current as per UL 943 standard In good condition and ...

Page 5: ...be used as a heating source Benzene is a chemical which is part of the gas supply to this cooking product which is consumed in the flames during combustion Exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion This appliance contains or produces chemicals which can cause serious injury or death and which are known to t...

Page 6: ...d 36 W Models 35 7 8 91 1 cm 35 7 8 91 1 cm min to 37 94 cm max 1 2 5 cm 29 7 8 75 9 cm Note Unit shown with standard island trim 47 7 8 121 6 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 cm max 60 152 4 cm 48 and 60 W Models ...

Page 7: ... 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm 28 1 16 71 2 cm Note Unit shown with standard island trim Side View ...

Page 8: ... trim add 1 5 cm To top of backguard add 8 0 3 cm To top of high shelf add 23 1 2 59 7 cm Gas requirements Shipped Natural or LP Propane accepts standard residential 1 2 1 3 cm ID gas service line Unit is field convertible with proper conversion kit Gas manifold pressure Natural 5 0 W C P Liquid Propane L P 10 0 W C P Electrical requirements 120VAC 60 Hz 4 ft 121 9 cm 3 wire cord with grounded 3 p...

Page 9: ... 9 kW power burner 15 000 BTU 4 4 kW 12 500 BTU 3 7 kW Griddle burner rating 15 000 BTU 4 4 kW 12 500 BTU 3 7 kW Grill burner rating N A 18 000 BTU 5 3 kW 16 000 BTU 4 7 kW Oven burner rating Right oven 30 000 8 8 kW BTU Nat LP Left oven 15 000 4 4 kW BTU Nat LP Both ovens 30 000 8 8 kW BTU Nat LP Oven interior width Right oven 23 58 4 cm Left oven 12 1 8 30 8 cm Both ovens 23 58 4 cm Oven interio...

Page 10: ...bove the range must be a minimum of 42 06 7 cm above the range cooking surface for the full width of the range This minimum height requirement does not apply if a range hood is installed over the cooking surface Note Minimum clearance for back wall is 0 with backguard or high shelf Note If a range hood is installed wall cabinets above the range have a different minimum clearance height Note Cleara...

Page 11: ...91 4 cm 66 min 167 6 cm to 72 max 182 9 cm 24 61 0 cm Wood Composite Overlay 0 0 cm 30 min 76 2 cm to 36 max 91 4 cm Wall Installation Island Installation Note This range comes standard with an Island Trim There must be a minimum of 6 15 2 cm clearance from rear of range to a combustible wall or 0 clearance to a non combustible wall Note Clearances from non combustible materials are not part of th...

Page 12: ... to the appliance Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold...

Page 13: ...tings the installer must use a heavy duty AGA design certified flexible connector of at least 1 2 1 3 cm ID NPT with suitable strain reliefs in compliance with ANSI Z21 41 and Z21 69 In Canada CAN 1 6 10 88 metal connectors for gas appliances and CAN 1 6 9 M79 quick disconnect devices for use with gas fuel In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connect...

Page 14: ... and must be installed with the unit Refer to Anti tip Device Installation section Some stainless steel parts may have a plastic protective wrap which must be peeled off The interior should be washed thoroughly with hot soapy water to remove film residues and any dust or debris before being used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed CAUTION Avoid any da...

Page 15: ...15 1 s t e p 2 3 4 Open door completely Fold latches backward until locked in place Slowly close until latches stop door Lift door up and out Door Removal ...

Page 16: ...rom couplings on all four corners 4 s t e p Lower range gently to keep any undue strain from legs and internal mounting hardware 3 s t e p Screw legs into couplings on all four corners The 48 W ranges have two additional legs located in the center of the unit Leg Installation 1 2 Measure the four corners in cutout area to verify if flooring is level For uneven or sloped floors level unit with meta...

Page 17: ...de and front to back Side trim of the lowest corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening 6 1 2 1 s t e p Lift unit and prop on wood blocks 7 s t e p Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner ...

Page 18: ...m where the right side of range facing range is to be located and Y dimension 60 ranges only see chart from where the left side of the range facing range is to be located WARNING TIPPING HAZARD To reduce the risk of property damage or personal injury install anti tipping device provided in accordance with the installation instructions in this document Device must be engaged properly to prevent pro...

Page 19: ...all when using an island trim or high shelf If using an 8 20 3 cm backguard add Dim B to the 1 1 4 Mark and drill 1 8 32 cm holes where bracket will be located Mount anti tip bracket hook to floor using screws provided Remove two screws from back of range Attach bracket to back of range using two screws A B Add only when using 8 backguard 30 12 3 4 32 4 cm 3 8 95 cm 36 16 40 6 cm 1 2 1 3 cm 48 16 ...

Page 20: ...mbustible wall Standoff Spacer Removal Installation 2 s t e p Make sure rear trim is properly installed 1 s t e p Connect gas and electrical Before placing appliance in operation always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company DANGER GAS LEAK HAZARD To avoid risk of personal injury or death leak testing of the appliance must be c...

Page 21: ...pport 4 0 95 cm 0 95 cm 0 95 cm s t e p Check that unit is level side to side and front to back The side trim must be 3 8 0 95 cm above countertop If unit is not level repeat Steps 5 7 of Leveling Adjustments Alignment section Installation 1 s t e p 2 2 s t e p 3 s t e p Carefully realign door on hinges Slide in and down Open door completely Fold latches forward until locked in place Close door Do...

Page 22: ...nvection fan comes on when switch is turned on 1 1 2 3 8 cm 3 8 0 95 cm A qualified installer should carry out the following checks All stainless steel body parts should be wiped with hot soapy water and with a liquid cleaner designed for this material If buildup occurs DO NOT use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted mater...

Page 23: ...cated below You will need it if service is ever required Model number ____________________________________________________________________________________ Serial number _____________________________________________________________________________________ Date of purchase __________________________________________________________________________________ Date installed ______________________________...

Page 24: ...iking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit vikingrange com in the US or brigade ca in Canada 055065 000A EN 031517 ...