Page 1: ...wood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20649 EN 080709J Viking Installation Guide Designer Freestanding 30 Dual Fuel Self Clean Sealed Burner Range ...

Page 2: ...ell you what can happen if the instructions are not followed WARNING CAUTION Warnings Important Safety Instructions_____________________________________________________3 Dimensions __________________________________________________________________________________6 Specifications ________________________________________________________________________________7 Clearance Dimensions Proximity to Cabi...

Page 3: ...hemicals which can cause serious injury or death and which are known to the state of California to cause cancer birth defects or other reproductive harm To reduce the risk from substances in the fuel or from fuel combustion make sure this appliance is installed operated and maintained in accordance to the instructions in this document WARNING TIPPING HAZARD To reduce the risk of property damage or...

Page 4: ...landing ledge 26 1 2 67 3 cm To front of door handle 28 1 4 71 8 cm Add 3 8 0 95 cm to overall depth of ranges installed against a combustible wall Additions to Overall Height To top of island trim add 0 0 0 cm To top of backguard add 6 15 2 cm To top of high shelf add 18 3 16 46 2 cm Gas Requirements Shipped Natural or LP Propane field convert with conversion kit purchased separately accepts stan...

Page 5: ... standard hood should be 30 76 2 cm min to 36 91 4 cm max above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the range hood installation instructions for additional information These dimensions provide for safe and efficient operation of the hood 66 min 167 6 cm to 72 max 182 9 cm 30 76 2 cm 6 15 2 cm Wood Composite ...

Page 6: ...with this manual before work begins Pressure Regulator All heavy duty commercial type cooking equipment must have a pressure regulator on the incoming service line for safe and efficient operation since service pressure may fluctuate with local demand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in ...

Page 7: ...used then rinsed and wiped dry Solutions stronger than soap and water are rarely needed NOTICE DO NOT use the handle or oven door to lift the oven Remove door before installation to ensure that it is not used to lift the unit DO NOT lift or carry the door by the handle Removing the door must be done by your dealer a qualified licensed plumber or certified gas installer Door Removal CAUTION Avoid a...

Page 8: ...ounding product to the frame of the unit may or may not be permitted through your local codes If ground to the frame is not permitted then a 4 conductor power cord must be used WARNING Electrical shock hazard To avoid risk of electrical shock personal injury or death verify your appliance has been properly grounded in accordance with local codes or in absence of codes with the National Electrical ...

Page 9: ...r in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition Use a 4 wire power supply cord kit rated for 40 amps 125 250 volts with closed loop terminals and marked for use with ranges Where local codes do not permit grounding through neutral use a 4 wire power supply cord The cord or conduit must be secured to the range with the strain relief bracket The electrical con...

Page 10: ...high corner must be 3 8 0 95 cm above countertop If leveling is required move unit out of opening Lift unit and prop on wood blocks 4 Feed supply cord up through hole in bottom of range back 5 6 Attach ground lead green with ground screw that was removed Attach line 1 red and line 2 black leads to outside terminal Attach neutral wire white to center terminal on terminal block 1 1 7 8 Push supply c...

Page 11: ...cording to the manufacturer s instructions Before placing appliance in operation always check for gas leaks with soapy water solution DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS Anti tip Device Installation Anti tip Device Installation cont 7 Set the high corner of range so that the top of side trim is 3 8 0 95 cm above countertop Level range to high corner Measure from floor to bottom of the ...

Page 12: ...95 cm above countertop If unit is not level repeat steps 5 7 of Leveling Adjustments Alignment section Slide range into place Be sure anti tip bracket slides into the anti tip opening Final Installation 1 2 Reattach door to range Open door completely Reattach hinge trim on both sides 3 4 Remove pins from holes in hinges Close door 5 If the door needs to be adjusted loosen hinge trim screws located...

Page 13: ...ol to scrape stainless steel Scratches are almost impossible to remove NOTICE When conducting performance test DO NOT run self clean cycle for more than 10 minutes with oven racks inside oven This could cause them to discolor due to the high temperature required for self cleaning 1 1 2 3 8 cm 3 8 0 95 cm Only authorized replacement parts may be used in performing service on the appliance All servi...

Page 14: ...27 26 ...