background image

2

DESCRIPTION

DGCU105   (30” W.) 

DGCU165  (36” W.)

DGCU155  (45” w.)

Cutout Width - Minimum 

28 3/4” (73.0 cm)

34 1/2” (87.6 cm)

42 7/8” (108.9 cm)

Maximum

29 7/8” (75.9 cm)

35 7/8” (91.1 cm)

44 1/8” (112.1 cm)

Cutout Height - Minimum

2 3/4” (7.0 cm)

Cutout Depth - Minimum

19 11/16” (50.0 cm)

Maximum

20 1/2” (52.1cm)

Overall Width

30 3/4” (78.1 cm)

36 3/4” (93.3 cm)

45” (114.3 cm)

Overall Height from Bottom 
(including connector)

4 1/4” (10.8 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

Not field convertible - Must be ordered from factory either natural or LP/Propane.  

Uses

standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

14,000 Nat./13,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

(3.5 Nat./2.8 LP [kw])

(3.5 Nat./2.8 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

10,000 Nat./LP (BTU) 

8,000 Nat./LP (BTU)

(3.5 Nat./2.8 LP [kw])

(2.9 Nat./LP [kw])

(2.1 Nat./LP [kw])

Left Center

N/A

14,000 Nat./13,500 LP (BTU)

10,000 Nat./LP (BTU)

(4.1 Nat./4.0 LP [kw])

(2.9 Nat./LP [kw])

Right Center

N/A

N/A

14,000 Nat./13,500 LP (BTU)

(4.1 Nat./4.0 LP [kw])

Right Rear-   

8,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

(2.1 Nat./LP [kw])

(2.1 Nat./LP [kw])

(1.8 Nat./LP [kw])

Right Front-  

6,000 Nat./LP (BTU)

6,000 Nat./LP (BTU)

8,000 Nat./LP (BTU)

(1.8 Nat./LP [kw]) 

(1.8 Nat./LP [kw])

(2.1 Nat./LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

93 lb. (41.9 kg)

DESCRIPTION

VGSU102   (30” W.) 

VGSU162  (36” W.)

Cutout Width - Minimum 

26 7/8” (68.3 cm)

34 3/8” (87.3 cm)

Maximum

29 7/8” (75.9 cm)

35 7/8” (91.1 cm)

Cutout Height - Minimum

2 1/2” (6.4 cm)

Cutout Depth - Minimum

18 5/8” (47.3 cm)

Maximum

20 1/8” (51.1cm)

Overall Width

30 3/4” (78.1 cm)

36 3/4” (93.3 cm)

Overall Height from Bottom 

5” (12.7 cm)

Overall Depth from Rear

21” (53.3 cm)

Gas Requirements

To field convert from natural or LP/Propane, the orifice spuds and regulator must be physically
changed.  Order conversion kit NK2VGSU to convert to natural and LPK3VGSU to convert to LP.

Uses standard residential 1/2” (1.3 cm) I.D. gas service line.

Electrical Requirements

120 VAC/60 Hz; 4 ft. (121.9 cm), 3-wire cord with grounded 3-prong plug attached to product.

Maximum Amp Usage

2.0 amps

Surface Burner Rating

Left Front-

16,000 Nat./15,500 LP (BTU)

16,000 Nat./15,500 LP (BTU)

(4.8 Nat./4.65 LP [kw])

(4.8 Nat./4.65 LP [kw])

Left Rear-   

12,000 Nat./11,500 LP (BTU)

12,000 Nat./11,500 LP (BTU) 

(3.6 Nat./3.45 LP [kw])

(3.6 Nat./3.45 LP [kw])

Center Front/Rear

N/A

12,000 Nat./11,500 LP (BTU)

(3.6 Nat./3.45 LP [kw])

Right Rear-   

8,000 Nat./7,500 LP (BTU)

8,000 Nat./7,500 LP (BTU)

(2.4 Nat./2.25 LP [kw])

(2.4 Nat./2.25 LP [kw])

Right Front-  

6,000 Nat./5,500 LP (BTU)

6,000 Nat./5,500 LP (BTU)

(1.8 Nat./1.65 LP [kw]) 

(1.8 Nat./1.65 LP [kw])

Approximate Shipping Weight

67 lb. (30.2 kg.)

80 lb. (36.0 kg)

BASIC SPECIFICATIONS

Reviews: