INSTALLATION AND USE FOR GUN AND FILE CABINETS 

 
1 – Installation 

 

ATTENTION:  for  your  safety,  the  cabinet  must  be 
fixed  to  the  wall  by  the  means  of  dowels  (not 
supplied)  through  the holes  on  the  rear  of  the  case.

 

Before  installing  a  cabinet,  it  is  suggested  to  check  the 
correct functioning of each of its parts (see points

 

2-10

)

:

 at 

purchase the  gun  cabinet  is locked.  In  case  of  mechanical 
cabinet  open  it  using  the  key  or,  in  case  of  electronic 
cabinet, using the emergency key. 

Note: for cleaning the 

wood  finish  cabinets  please  wipe  with  wet  cloth 
only.

 

 

2 - Application of the barrel support 

 

Remove the sticker  or stickers protection film (depending 
on the model) from the barrel support and fix it to the case 
at  about  95  cm  height  from  the  bottom  (see  fig.  1a). 
Position  of  the  barrel  support  suitable  only  for  4430  and 
4430.L item as shown in fig. 1b.

 

  

 

3 – Assemby instructions for insides 
shelves (for file cabinets only – see 
fig. 2) 

 

1.

 

Place  the  side  wall 

A

  with  8  mm.  hole  inside  the 

cabinet, in contact with right wall. 

2.

 

Place the side wall

 B

 inside the cabinet in contact with 

left wall. 

3.

 

Fix  shelves 

C

  on  side  walls  by  using  relevant  hooks. 

Note: maximum capacity for each shelf is 15 kg.

 

 

4 – Assemby instructions for insides 
shelves, barrel support and gun-butt 
base (for modular cabinets only – see 
fig. 3) 

 
 

1.

 

Place the side wall

 

A 

inside the cabinet in contact with 

left wall. 

2.

 

Fix shelves 

B

 on side walls by using relevant hooks.

 

Note: maximum capacity for each shelf is 15 kg. 

 

3.

 

Remove the stickers protection film from the gun butt base 

C

 and fix it to the base.

 

4.

 

Remove  the  sticker  protection  film  from  the  barrel  support  and  fix  it  to  the  case  at  about  95  cm 
height from the bottom (see fig. 1a).

 

 

5 - First opening / Opening with emergency key 
     (only for electronic cabinets) 

 

The  mechanical  emergency  key  is  contained  in  a  sealed  envelope  inside  the 
package  and  is  used  for  the  first  opening  of  an  electronic  cabinet  or  further 
openings in case of electronic card damage, lack of power supply (batteries over), 
or  when  opening  code  is  forgotten.  To  open  a  cabinet  with  emergency  key  is 
necessary to:  

 

1.

 

Remove  the  plastic top  upward  the  keypad  in  order  to  access the  key  hub  (see 
fig. 4). 

2.

 

Insert the key and turn it clockwise till it stops. 

3.

 

Turn the knob clockwise while keeping the key firm. 

 

Once the door is opened, remove the key and put back the key hub top.

 

Keep  the 

present instructions and the emergency key in a secured place but never 
inside the cabinet  itself!

 

 

 

6 - Insert / Replacing batteries (only for electronic cabinets) 

 

1.

 

Open the cabinet and take the battery case out of its housing by simply removing the plastic top that covers it (see fig. 1a). 

2.

 

Remove the battery case. 

3.

 

Remove the batteries (in case of replacement). 

4.

 

Insert new batteries

 

paying attention to the polarity

 

indicated on the battery case. 

5.

 

To check whether the safe works press any key: the”OK” green LED must blink slightly. 

6.

 

Place the battery case back into its housing and put back its cover. 

 

ATTENTION:

 

use only AA LR6 type 1,5V  alkaline batteries. All 4 batteries of the same safe  must be replaced  at once. Do not use together new and old 

batteries  or  batteries of a  different  type and  quality.

 

When  the  batteries  are  almost  empty  any  pressed  key  will  make  the  “BATTERY”  red  LED 

blink: replace then the batteries. N.B. : the electronic card has a non volatile memory so the memorized codes are not erased when power 
supply is removed. 

7 – Code setting (min. 3 - max. 8 digits; only for electronic cabinets) 

 

1.

 

With  door  opened

 

(retracted lock-bolts)  press “C”  or “COMB”  (according to the model) key  on the keypad  until “NEW CODE”  green  LED 

lights up. 

2.

 

Within 10 sec enter a personal code of min. 3 - max. 8 digits. (N.B.: if within 10 sec no code is entered, restart from point 1). 

3.

 

Press “ENTER” or “E” (according to the model). A beep will confirm that the code is memorized. 

Do not forget your personal code.

  

Before 

closing the cabinet door it is very important to check whether the code is set correctly by following the instructions described at point 8.

 

 

8 - Code check (only for electronic cabinets) 

 

1.

 

With door opened

 

(retracted lock-bolts) turn the knob counterclockwise, as for closing the cabinet, making sure the lockbolts are completely 

out of their housings.  

2.

 

Enter your opening code. 

3.

 

Press “ENTER” or “E” (according to the model). 

4.

 

Turn the knob clockwise within 4 seconds. If the lock-bolts do not enter back into their housings there is an error in the code setting. To correct an 
error use the emergency key (see paragraph

 

5

), turn the knob counter clockwise and repeat the procedure of code setting described at parag

raph 

7

.

 

 

ATTENTION:

 

Viro is not responsible for any inconvenience caused by an erroneous code setting or if code is forgotten. 

 

9 – Closing (only for electronic cabinets) 

1.

 

Close the door manually. 

2.

 

Turn the knob counter clockwise. 

 

10 – Opening (only for electronic cabinets) 

 

1.

 

Enter the set opening code.

 

2.

 

Press “ENTER” or “E” (according to the model). 

3.

 

Turn the knob clockwise within 4 sec. 

 

11  –  How  to  replace  the  cylinder  (only  for 
cabinets with security escutcheon) 

 

1.

 

With  door  opened

 

turn  the  key  anticlockwise  making  lock-bolts 

come completely out and remove the key.

 

2.

 

Unscrew 

A

  screws  with  a  cross-tip  screwdriver  and  take  out  the 

security escutcheon 

B

.

 

3.

 

Insert  the  key  directly  into  the  cylinder  and  unscrew 

C

  screw  with  a 

screwdriver placed inside the door beneath the lock-bolts.

 

4.

 

Turn the key slightly and pull the cylinder until it can be unlocked and 
therefore removed.

 

5.

 

Replace  with  a  new  cylinder  complete  with  key.  Then  turn  the  key 
gently while pressing the cylinder up to the end.

 

6.

 

Screw the screw 

with a screwdriver. 

7.

 

To check if cylinder works correctly, 

open  the door

 and turn the key 

clockwise  and  anticlockwise  to  make  lock-bolts  come  in  and  out. 

ATTENTION:  possible  problems in  the key  rotation are due  to  an  incorrect alignment  of  the  cylinder  into  its  housing.  To  solve 
them, it would be necessary

 

to unscrew the screw C and put the cylinder in a correct position

8.

 

Remove the key and put the security escutcheon back into the cylinder. N.B.: movable ring 

D

 should be positioned as for fig. 5

 

9.

 

Screw all 

screws while keeping security escutcheon blocked in its position 

10.

 

To check if cylinder works correctly, 

open the door

 and check if it turns without encountering frictions. 

ATTENTION: possible problems in 

the key rotation are due to an incorrect alignment of the security escutcheon. To solve them, it would be necessary

 

to unscrew 

all A screws and to refit them into the correct position

 

Warranty conditions and contents 

All  Viro  products  undergo  the  most  stringent  testing  and  therefore  guarantee  reliability.  Viro  SpA  reserves  the  right  to  introduce  modifications  or 
improvements to its  products,  which  may  deem desirable without  obligating  itself  to  install such improvements to  its  previously manufactured safes. Viro 
SpA guarantee their products to be free from defects in material and manufacturing for the period provided for by effective law on purchasing time (Decr. 
Leg. 2/02/02 n.24 that puts into effect Directive No 1099/44/CE) and will replace or repair at no charge all component parts of the product under warranty – 
after consultation with our technical  department or  an authorised  Service Centre - should  they be defective  due to  a manufacturing  or  material  flaw. The 
warranty covers the replacement of the components, ex-works, if defective, but does not include the safe opening costs, the removing costs and the final 
replacement, or any other cost or damage, even though related to the defective product. The property damage responsibility of Viro SpA will be in no case 
higher  than  the  selling  price  of  the  article  itself,  even  if  the  damage  –  including  the  content  of  the  safe  –  is  due  to  forcing,  theft  or  burglary.  The  warranty 
shall not apply to any Viro component part which has been subject to misuse, neglect, incorrect installation of maintenance, or to a use in contravention of 
instructions furnished by the Company. The warranty does not extend to safes which have been installed in unsuitable environments or which have been 
repaired by unauthorised personnel or suffered damage in transit, or to any other circumstance not ascribable to faults in manufacture. Viro SpA shall not 
be liable for any direct, indirect and consequential damage and/or injury arising from the malfunctioning of their product or from the safes, or if caused by 
negligence  or  by  lack  of  compliance  with  the  instructions  manual.  The  warranty  shall  take  effect  from  the  date  of  purchase.  Sales  receipt  (fiscal  receipt, 
cash-desk  receipt,  invoice,  delivery  note  or  the  like)  validates  the  date  of  purchase,  irrespective  of  the  actual  fitting  date.  Failing  a  sales  receipt,  the 
warranty  shall  be  calculated  from  the  date  of  manufacture  of  the  product,  which  shall  be  determined  from  its  serial  number.  In  case  of  purchasing  of 
safe/cabinet supplied complete with external contacts for the emergency opening (without  mechanical emergency opening), should the  safe not  be  open 
due to its block or malfunctioning, Viro S.p.A. is free from any responsibility for damages caused to things or persons, even if connected or depending to 
the  malfunctioning,  including  the  content  of  the  safe.  The  Seller  is  completely  excluded  from  any  costs  and  charges  for  forced  opening  of  the 
safes/cabinets, their removal and further new installation of the product and the restoration of the places conditions. 
 
 
 
 
 
 
 
 
 
 

20444049300000D – Rev.2  06/19 

fig. 4 

 

COVER 

 

BATTERY BOX 

 

ONLY FOR 

 4430 AND 4430.L ITEMS 

 

fig. 1a 

fig. 1b 

 

HOLE 

HOOK 

fig. 2 

fig. 5 

N.B.: the gun cabinet cylinder 

can be replaced by all cylinders 

working with DIN cam and with 

same dimensions showed in 

below icon. 

HOOK 

fig. 3 

Produit 

conforme 

à 

la 

directive 

européenne 

2014/30/UE

 

(compatibilité  électromagnétique)  et  à  la  directive 

2011/65/UE

 

(ROHS). La déclaration UE est téléchargeable du site 

www.viro.it

 

 

Viro S.p.A

. Via Garibaldi n.4 - 40069 Zola Predosa (BO) Italy

 

-

 www.viro.it

 - E-mail: viro@viro.it

 

Tel. +39 051 6176511 - Fax +39 051 755079 (Sales Department) - Fax +39 051 6176627 (After-Sales Support)

Reviews: