background image

 

 

 
 

Service 

Managed

 Gateway

TM

 

 

 

Installing and Configuring the  
GW8600 SMG

 

 

 

 

 

Issue 

1.1 

Date 

14 August 2007 

 

 

Summary of Contents for GW8600 Service Managed Gateway

Page 1: ...Service Managed GatewayTM Installing and Configuring the GW8600 SMG Issue 1 1 Date 14 August 2007 ...

Page 2: ...he high voltage end of the PSU 4 2 1 2 Connect cables through access points 4 2 1 3 Protect unused access points 5 2 2 Unpacking the GW8600 SMG 5 2 3 Assessing the GMS GPRS signal strength at the installation location 5 2 4 Connecting terminal equipment to the DTE ports 6 2 5 Connecting the power supply unit 6 2 6 Reattaching the battery 7 3 Configuring the ADSL gateway 8 4 Configuring WebWayOne 2...

Page 3: ... GPRS through HyperTerminal This document does not explain in detail how to use the web interfaces to configure the SMG or WebWayOne 2424B Communicator 1 2 Readership This document is for network engineers 1 3 More information For more information about WebWayOne 2424B Communicator read the WebWayOne document Getting Started With Your WebWayOne 2424B Communicator 1 4 Terminology ARC Alarm receivin...

Page 4: ...upport the cables at the points that are shown in Figure 1 ensure the wiring is supported from another appropriate point or by an appropriate group of cables Figure 1 A correctly wired GW8600 SMG 2 1 2 Connect cables through access points Connect cables to the GW8600 SMG through the access point in the upper left of the box which has a removable PVC faceplate or through the 20mm knockout holes on ...

Page 5: ...nst the packing list that is inside the packaging Figure 2 shows the components of the GW8600 SMG Figure 2 The components of the GW8600 SMG 2 3 Assessing the GMS GPRS signal strength at the installation location Before you install or mount the GW8600 SMG ensure the GMS GPRS signal is adequate at the installation location The 7 segment display on the upper right hand corner of the WebWay 2424B Comm...

Page 6: ...ment display 7 Adjust the position of the antenna until the display shows 3 or above 8 Secure the antenna at the position with the strong signal We recommend that you secure the antenna behind the PVC trucking to provide additional security 9 Disconnect the battery from the box This step is a safety precaution 2 4 Connecting terminal equipment to the DTE ports For a full explanation of how to conn...

Page 7: ...bove the knockout hole on the bottom of the box Use a cable that meets the specifications in Table 1 Insulation Doubly insulated Secondary insulation PVC Conductor make up 30 0 25 mm Conductor CSA 1 5mm2 Cable type 3183Y Table 1 Specifications for the 3 core mains cable 2 6 Reattaching the battery 1 Attach the red lead from the PSU to the red contact 2 Attach the black lead from the PSU to the bla...

Page 8: ...port The RJ11 will fit into both 4 If you are using ISDN back up connect one end of the black ISDN cable to the port marked J1 on the board J1 is next to LED14 This cable has an RJ45 connector on both ends Connect the other end to an ISDN port If you are using modem back up connect the RJ11 end of a black cable to the port marked J8 on the board 5 Turn on the mains power at the isolation switch Wh...

Page 9: ...go to section 4 2 If the network at the alarm site uses static IP addressing get the information in Table 2 before you configure the WWO 2424B Communicator Parameter Name Value for this installation fill in the field IP address Subnet mask Default gateway IP address Table 2 Configuration parameters for the WebWayOne 2424B Communicator 4 2 Attaching the GW8600 SMG to a console 1 Connect the 3 way M...

Page 10: ...t Gw Unassigned Net Mask 255 255 255 0 MAC Address 00 0A 07 00 00 59 4 3 Configuring the WWO2424 board 4 3 1 Connect through HyperTerminal 1 Select Start All Programs Accessories Communications HyperTerminal 2 Type a name to associate with the connection 3 In the Connect To dialog box in the Connect using drop down list select the COM port that is connected to the WWO 2424B Communicator 4 Click OK...

Page 11: ...ically the subnet mask is set automatically Do not type a subnet mask Local port Set LOCAL_PORT local port number Default gateway Set DEFAULT_GW IP address of the local gateway IP address of the ARC gateway Set IP_ADDRESS IP address of ARC gateway ARC port Set IP_PORT port number of ARC GSM telephone number Set MY_GSM_NUMBER GSM telephone number GSM PIN code Set GSM_PIN_NUMBER PIN number Table 4 C...

Page 12: ...sue 1 1 Page 12 of 12 5 Attaching the lid Attach the lid after you configure the WWO 2424B Communicator board on the GW8600 SMG 1 Put the lid on the box Earth the lid by attaching the grounding strap to the lid with the nut that is supplied 2 Close the lid and screw it firmly in place ...