Instruction Manual 

 

VISAM TouchPanel 

 

VTP-BC70 / VTP-BC100 

 

A product of the the 

VBASE

 - HMI/SCADA – family 

 

 

Document: 

HB_VTPBC_70_100v1.0e_FINAL.doc

 

 

Version: 1.0, English 

 
 
 
 

 

Summary of Contents for VTP-BC100

Page 1: ...Instruction Manual VISAM TouchPanel VTP BC70 VTP BC100 A product of the the VBASE HMI SCADA family Document HB_VTPBC_70_100v1 0e_FINAL doc Version 1 0 English ...

Page 2: ... Technical Support Tel 49 0 2631 941288 40 E Mail support visam de We have taken all possible measures to ensure the correctness and completeness of this documentation Despite all care errors cannot be avoided and we would appreciate any information or ideas at any time We point out that the in the document used software and hardware terms as well as the trademarks of their respective companies ar...

Page 3: ... Power Switch 11 3 10 Environment Conditions 11 3 11 Safety 11 4 SOFTWARE SETTINGS 12 4 1 Setup Changing of the network IP address 12 4 2 Save changes to settings permanently 13 4 3 Automatic Startup of the HMI Application 13 4 4 FTP Server Data Transmission 13 4 5 Touchscreen Calibration 15 4 6 Remote control of the device via network 16 4 7 Connect network share 18 4 8 Additional Settings in Win...

Page 4: ... L doc 5 2 PIN Assignment of the serial interface 26 5 2 1 Serial interface RS 232 422 485 COM1 26 5 2 2 Serial interface RS 422 485 COM2 RS 485 COM3 26 5 2 3 USB Verbindung 27 5 3 Dimension and Cutout 28 5 3 1 Weight VTP BC70 100 28 5 3 2 Cutout 28 5 4 Illustration Directory 30 ...

Page 5: ...amed without referring to patent rights The existence of such rights cannot be excluded 1 1 2 PersonnelQualification The construction of the following instruction and the usage of the VBASE product family require basic knowledge about the used windows operating system and the used remote systems e g SPS The in this document described product use is directed exclusively to professionals or trained ...

Page 6: ... the latest and detailed descriptions accompanying the products 1 3 Used symbols Note Information that should be noted to ensure a faultless and effective operation Hint Tips and hints for the efficient use of the system respectively system optimization ESD Warning of damage to the systems components by electrostatic discharge Precautions should be taken when handling electrostatically sensitive c...

Page 7: ...re is described in a separate description 2 2 The Article and Model number At this point a brief commentary on the article and model numbers of these VTP series is given The model number is rather general and serves as a rough identification of the VTP The model number provides information about the operation system the display size and the built in version of the VTP The article number however co...

Page 8: ...rfaces VTP BC70 BC100 Serial interface 10 100 Base T Ethernet RS 232 422 485 COM1 D89 x 1 RS 422 485 COM2 4 Pin connector x 1 RS 485 COM3 2 Pin connector USB 1 x USB 2 0 Client 1 x USB 2 0 Host Extensions 1 x Micro SD Memory Card Slot 3 3 LCD Display VTP BC70 Size 7 WVGA TFT LCD Brightness 500 cd m Viewing angle 140 120 H V Contrast ratio 700 1 Resolution 800 x 480 Pixel VTP BC100 Size 10 1 WSVGA ...

Page 9: ... voltage 24 VDC Electricity demand maximum 7 W VTP BC 70 9 W VTP BC 100 3 6 Integrated Software Operation system Microsoft Windows Embedded CE 6 0 R3 HMI SCADA VBASE Compact RT The integrated software is embedded software that may be only operated on the delivered hardware system 3 7 Interface Arrangement The arrangements of the interfaces are depicted in the following figures Figure 2 Interface A...

Page 10: ...1 0 V I S A M T O U C H P A N E L V T P B C 7 0 1 0 0 HB_VTPBC_70_100v1 0e_FINA L doc Figure 3 Interface Arrangement VTP BC 100 ...

Page 11: ...wer Supply 3 9 Power Switch VTP BC70 and VTP BC100 do not have power switches 3 10 Environment Conditions Environmental Temperature while operating 20 60 C Storage Temperature 30 70 C Humidity 40 C 10 90 relative non condensing Vibration Resistance 1 Grms in average and while operating with a HDD 3 11 Safety Safety front side IP66 BSMI CCC FCC UL ...

Page 12: ...t menu Figure 6 Connection Here open the property of the network card by a double click on its name here IAG81681 Figure 7 Ethernet Setup In the now opened property window insert the desired network IP address Subnet Mask and if needed the Default Gateway In the second tab Name Server the IP address of the DNS Server and the WINS Server can be inserted Confirm the input by clicking on OK top right...

Page 13: ...er starting and booting of the device Was the HMI Application and as such the runtime environment shutdown it can be restarted with the help of the icon START HMI respectively by selecting it from the Start Menu Programs without having to restart the whole device The runtime environment with all accessories is located ex factory in the directory HardDisk VOK 4 4 FTP Server Data Transmission The de...

Page 14: ...E L V T P B C 7 0 1 0 0 HB_VTPBC_70_100v1 0e_FINA L doc Password visam FTP Directory Harddisk The FTP Server is also used by the VBASE Editor for the transmission of projects and the setup of the device see Help system of the editor ...

Page 15: ...t a different position To calibrate select from the Start Menu Settings Control Panel and then the program Stylus A window with two tabs opens Figure 10 Touchscreen Calibration Double Tap setting up the double click speed Calibration to recalibrate the touchscreen Follow the instructions on the screen and touch the corresponding calibration points successively on the touchscreen Save your settings...

Page 16: ...e On the PC system from which you want to connect to the panel a compatible VNC Viewer e g UltraVNC VNCviewer must be installed and a network connection must be established Ex factory the VNC Server is provided with a default password visam At the connection establishment the password will be queried Figure 11 VNC Connection Establishment Remote Control After the successful connection establishmen...

Page 17: ...ly the VNC Connection can be changed according to your needs with the help of the program vncconfig The VNC Server is configured ex factory that you don t need to make any changes The program vncconfig can be found in the Start Menu Programs Tools Figure 13 VNC Server Einstellungen The password of the VNC Connection can be changed by clicking the button Configure see Figure 12 Save your settings b...

Page 18: ...4 Prompt Enter here the following commands net use share name servername share user user password password share name represents individual used name for the share servername share describes the share on a distant device user represents the name of the user who has the authorization to use the share password Represents the password which is used for the user that has the authorization to use the s...

Page 19: ...1 The Tool CE NotepadPlus CE NotepadPlus is a simple text editor for Windows CE 4 9 2 The Tool cmd cmd provides the prompt of the operating system Windows 4 9 3 The Tool control control opens the settings directory of the operating system Windows CE 4 9 4 The ToolRegistry Saver Registry Saver saves he registry see chapter 4 2 4 9 5 The Tool vncconfig vncconfig opens the configuration of the VNC Se...

Page 20: ...e view changes accordingly As in the figure 15 depicted the other tabs cannot be completely displayed But the tabs can be moved by clicking the small arrows in the top right Requirements for the functionality of the VBASE runtime environment The following settings should not be changed at all They are part requirements for the VBASE project transmission from and to the VBASE runtime environment VO...

Page 21: ...n as you click in one of the input fields a small window with a desktop keyboard appears the Input Panel With the help of this keyboard you can directly process the inputs on the VTP if you do not remotely control the device Figure 17 VTP Tool Creation of a new user and the Input Panel Confirm your inputs by clicking on the button Add User The window will be closed and the new user will be inserte...

Page 22: ...e user to write files into the home directory and to change or delete existing files If the option hidden files is checked the user can see all hidden system files in this directory and is able to change and or delete them Figure 18 VTP Tool Change of user authorization Delete user To delete a user the corresponding user must be selected with a double click from the entry in the list The selected ...

Page 23: ...ction to the below stated default directory Neither a user name nor a password must be specified The third option allows an anonymous user to write files into the default directory The fourth option allows besides an anonymous FTP connection to the default directory also the FTP connection to the home directory with a corresponding user login The entry in the input field Default directory determin...

Page 24: ... VTP This option allows the Telnet access to the VTP without specifying any user information This function is required to start or stop the VBASE runtime environment VOK via the VBASE editor The second option restricts the access to the VTP via Telnet to the users that have the corresponding authorization for the Telnet access If this option is checked a user login is required for the Telnet acces...

Page 25: ... 0 1 0 0 2 5 HB_VTPBC_70_100v1 0e_FINAL doc 5 Appendix 5 1 Fuse These VTP are protected against electrical damage by a fuse The fuse cannot be changed readily as trained personnel is required The fuse is triggered if a voltage 32VDC is applied ...

Page 26: ...7 0 1 0 0 HB_VTPBC_70_100v1 0e_FINA L doc 5 2 PIN Assignment of the serial interface 5 2 1 Serial interface RS 232 422 485 COM1 Figure 21 RS 232 422 485 COM1 5 2 2 Serial interface RS 422 485 COM2 RS 485 COM3 Figure 22 RS 422 485 COM2 RS 485 COM3 ...

Page 27: ...V I S A M T O U C H P A N E L V T P B C 7 0 1 0 0 2 7 HB_VTPBC_70_100v1 0e_FINAL doc 5 2 3 USB Verbindung Figure 23 PIN Assignment USB connection ...

Page 28: ... Weight VTP BC70 100 Weight 1 kg 1 2 kg 5 3 2 Cutout VTP BC 70 Dimension 203 x 150 x 44 mm width x height x depth Cutout 192 x 138 5 mm Maximum mounting panel thickness 6mm VTP BC 100 Dimension 272 x 214 x 43 mm width x height x depth Cutout 260 x 201 5 mm Maximum mounting panel thickness 6mm Figure 24 Panel mounting ...

Page 29: ...V I S A M T O U C H P A N E L V T P B C 7 0 1 0 0 2 9 HB_VTPBC_70_100v1 0e_FINAL doc Figure 25 Dimension VTP BC 70 Figure 26 Dimension VTP BC 100 ...

Page 30: ...uchscreen Calibration 15 Figure 11 VNC Connection Establishment Remote Control 16 Figure 12 Remote Desktop 16 Figure 13 VNC Server Einstellungen 17 Figure 14 Prompt 18 Figure 15 Tools in the menu Tools 19 Figure 16 VTP Tool Start Picture 20 Figure 17 VTP Tool Creation of a new user and the Input Panel 21 Figure 18 VTP Tool Change of user authorization 22 Figure 19 VTP Tool FTP Server settings 22 F...