AMBER CLASSIC /  

AMBER CLASSIC X

 

Wireless Emergency Response System

 

 

User's Guide

 
 
 
 
 

 

 
 

 

 

 

Summary of Contents for AMBER CLASSIC

Page 1: ...D 301436 1 AMBER CLASSIC AMBER CLASSIC X Wireless Emergency Response System User s Guide ...

Page 2: ... is automatically recharged What s Included Before you begin to set up your system make sure you have all the necessary components Base Unit 110V 12V transformer For USA use cat OH 48109AT Wrist Pendant transmitter MCT 212 supplied with necklace not evaluated by UL Additional Accessories Optional Wrist Pendant transmitter MCT 211 supplied with necklace UL listed Battery operated smoke detector MCT...

Page 3: ...ER Green Normally ON indicating that your system is properly connected to the power outlet TROUBLE Red Normally OFF If LED flashes there is a problem with the Base Unit or one of the devices described on the display of AMBER CLASSIC STATUS Yellow Normally OFF which indicates the system is in HOME mode FLASHES when unit is in AWAY mode Special Functions Calling for help by using an emergency pendan...

Page 4: ...isonic representative for further details Step 2 Rotate the Antenna on the Base Unit Figure 3 The antenna helps your pendant s and detector s communicate with your Base Unit Rotate the antenna to its utmost vertical position Step 3 Connect the Base Unit to your Telephone Line Figure 4 The Base Unit communicates with your Monitoring Center through your telephone line 1 Locate the phone jack on your...

Page 5: ...n electrical power is supplied to the AMBER CLASSIC X the green light on the front panel illuminates Step 5 Base Unit is now connecting you to the Monitoring Center After installation a Monitoring Center representative will begin speaking to you When your Monitoring Center representative answers you can hear them talking to you through the Base Unit You can talk to the representative by speaking o...

Page 6: ...hen pressed an emergency alarm is reported to the Monitoring Center and a two way voice communication is opened between the unit and the Monitoring Center CALL gray When pressed a non emergency message is reported to the Monitoring Center and a two way voice communication is opened between the unit and the Monitoring Center CHECK gray This button should be pressed to Answer Incoming Calls When the...

Page 7: ... Yellow Off Away mode On Home mode Flashes Active reminder Trouble messages are shown on the Base Station display AMBER CLASSIC only until they are resolved Pressing the CHECK button confirms the trouble condition and cancels the beeps The Base Unit continues to transmit trouble messages every eight hours until the problem is resolved Changing System Status When the user wants to leave the premise...

Page 8: ...es the fall detector to its upright position the unit will announce Fall Device Upright System OK In the Event that No Activity is detected Motion Detector Transmitter Optional The motion detector and door contact transmitter are used to monitor the user s activity If no activity is detected by the enrolled transmitter s during a pre defined amount of time the AMBER CLASSIC AMBER CLASSIC X will re...

Page 9: ...ou must then press the pendant transmitter whereby the unit will announce and display AMBER CLASSIC only Test Complete MAINTAINING YOUR SYSTEM When a Pendant s Battery is Low When a pendant transmitter s button is pressed and its battery is low the pendant transmitter flashes rapidly several times per second and the red light on the Base Unit flashes continuously until the pendant s battery is rep...

Page 10: ...tative You hear strange tones when using the phone Your Base Unit is trying to call your Monitoring Center Hang up so your system can report a problem to the Monitoring Center When it finishes you can use the phone You hear noise interference when using your cordless phone The cordless phone might be picking up noise interference from the Base Unit If the cordless phone s base is connected to the ...

Page 11: ...an evacuation plan Draw a floor plan of your home displaying two possible exit areas of each room including windows Don t forget to mark the location of every installed smoke detector Test all smoke detectors periodically this must be performed in a qualified testing laboratory to ensure their serviceability Replace batteries as required Make sure that everyone understands the escape plan and is a...

Page 12: ...ESTRUCTION OF OTHER PROPERTY OR FROM ANY OTHER CAUSE EVEN IF MANUFACTURER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE THE MANUFACTURER SHALL HAVE NO LIABILITY FOR ANY DEATH PERSONAL AND OR BODILY INJURY AND OR DAMAGE TO PROPERTY OR OTHER LOSS WHETHER DIRECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION However if the Manufacturer is held...