Electronic Muscle Stimulator Manual

 

 
 

 

 

     EMS 4000 and 4000R  

 

 
 
 
 
 

© 2007  Vitalityweb.com, Inc 

 

Summary of Contents for EMS 4000

Page 1: ...lityweb com Inc Attn Repairs 13820 Stowe Dr Poway CA 92064 2007 Vitalityweb com Inc VITALITYWEB COM BACKSPORT HEALTH PRODUCTS Electronic Muscle Stimulator Manual EMS 4000 and 4000R 2007 Vitalityweb com Inc ...

Page 2: ...e of the irritation Pregnancy The safety of stimulation for use during pregnancy or delivery has NOT BEEN established Adequate precautions should be taken with suspected heart problems or epilepsy Take precaution when stimulating over menstruating uterus or where sensory nerve damage is present by a loss of normal skin sensation The user s psychological state and use of drugs will influence treatm...

Page 3: ... and do not use Contact Vitaltiyweb to have the unit repaired immediately If you feel a sharp tingling sensation when stimulating Make sure you have a good connection between your skin and the electrode pad When using the rubber pads be sure to use a conductive agent such as water or a conductive gel between your skin and the electrode pads Make sure the pads are located over the muscle belly thic...

Page 4: ... mode can also be used to exercise upper lower abdominals upper lowerback muscles and abdominals obliques The Reciprocation channels are 1 2 and 3 4 3 DO S AND DON TS DO Follow the advise of you Physician Health care professional DO Turn all intensity knobs off counterclockwise to left before turning on the EMS unit DO Keep the stimulator clean DO Make sur you use a conductive agent such as water ...

Page 5: ...al pulses and is often used by bodybuilders scoliosis patients and chronic pain sufferers Russian stimulation is a higher frequency and more intense than the normal operating mode You must use caution when using this mode by reducing time durations and power levels Please consult your physician for specific recommendations and usage This mode is activated by pressing the RUSSIAN STIM switch to ON ...

Page 6: ...timulation in the beginning can make your muscles sore much like going to the gym and lifting weights that are too heavy for you We do not subscribe to or promote the No pain no gain myth 7 CONTACT US if you have a problem or question We generally can solve 99 of the problems over the telephone or by e mail sales vitalityweb com We are here to answer any questions that will allow you optimize the ...

Page 7: ...of the back Using one channel place the pads on the right side of the centerline Put one pad on the top and one pad on the bottom Now repeat the process for the left side using the second channel Make sure the pads are each about one inch from the center of the back You may now adjust the unit for stimulation 9 CONTROLS 1 Frequency Knob This controls the frequency level or how many pulses per seco...

Page 8: ...ace one pad on one side of the imaginary line and the other pad on the opposite side Make sure there is about a gap between the pads You are now ready to adjust the unit for stimulation TRICEPS Place the small Velcro strap around the middle of the biceps or a little above the middle Extend your arm downward with the palm of your hand facing towards the back Draw an imaginary line from the center o...