TECHNICAL SPECIFICATIONS

Suitable for All Pressures

Minimum Pressure = 17kPa
Maximum operating Pressure = 500kPa
Maximum operating Temperature = 65 deg. Celsius

For domestic use only.

CONFIGURATION

Mains Pressure systems  Remove the valve insert from the valve nipple and change aerator to the WELS rated one
 supplied.
Unequal Low systems  Ensure the valve nipple is attached to the cold in-feed hose (flow arrow aligned to the 

water flow).

Equal Low systems 

Remove the all valve insert from the valve nipples.

INSTALLATION

For pressures exceeding 500kPa, install a pressure limiting valve.  Failure to do so may void the warranty.

•  Before commencing installation turn off the water supply.
•  Position tap in 35mm hole, making sure the seal between tap and supporting surface is in place.
•  Anchor to bench with fittings pack.
•  Where applicable, it is important to ensure the base ring is hand-tight on the mixer, prior to installation.
•  Thoroughly flush all pipes to eliminate any remaining dirt and residue and install inline filters.
•  Connect supply hoses to plumbing connections.  

Minimum bend for flexible hose is 35mm radius.  

Do not stretch, crush or twist hoses. Do not swage hose ends.

•  Turn on mains supply.
•  Check for leaks.

Plumbers Note: Do not pressure test this mixer under static pressure.