Owner’s Instruction and Operation Manual

U.S. Environmental Protection Agency

Certified to comply with 2020 particulate 

emissions standards.

SAFETY NOTICE: If this heater is not properly installed, a house fire may result. For 
your  safety,  follow  the  installation  instructions.  Never  use  make-shift  compromises 
during  the  installation  of  this  heater.  Contact  local  building  or  fire  officials  about 

permits, restrictions and installation requirements in your area. NEVER OPERATE THIS 
PRODUCT WHILE UNATTENDED.

CAUTION!  Please  read  this  entire  manual  before  you  install  or  use  your  new  room 

heater. Failure to follow instructions may result in property damage, bodily injury, or 

even death. Improper Installation Will Void Your Warranty!

Save These Instructions In A Safe Place For Future Reference.

 CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals 

including carbon monoxide, which is known to the 

State of California to cause cancer, birth defects, 

and/or other reproductive harm. For more 

information, go to www.P65warnings.ca.gov

8 5 3 9 1 4 B - 2 3 0 2 L

VG5713

R

Report Number: F21-735

Certified to ASTM E1509-12 (2017) and 

Certified to ULC-S627-00-REV1

Mobile Home Approved

Model Number:

Summary of Contents for VG5713

Page 1: ...ire officials about permits restrictions and installation requirements in your area NEVER OPERATE THIS PRODUCT WHILE UNATTENDED CAUTION Please read this entire manual before you install or use your new room heater Failure to follow instructions may result in property damage bodily injury or even death Improper Installation Will Void Your Warranty Save These Instructions In A Safe Place For Future ...

Page 2: ...O OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH THE OPERATING INSTRUCTIONS IN THE OWNER S MANUAL Heating Specifications Fuel Burn Rate lowest setting 1 65 lbs hr 0 75 kg hr Pellet size may effect the actual rate of fuel feed and burn times Fuel feed rates may vary by as much as 20 Use PFI listed fuel for best results Burn Time lowest setting 30 hrs approximate Hopper Capacity 50 lbs 22 7 ...

Page 3: ..._________________________________________ If no Date of inspection of existing venting system ___________________________________________________________________ COMMISSIONING Confirm Hearth Pad Installation as per Installation Instructions Confirm proper placement of internal parts Check soundness of door gasket and door seals Confirm clearances to combustibles as per installation instructions in...

Page 4: ...led wires out of the top of the stove There will be two wire harnesses as shown 2 Unpack the top mount controls and ensure that the wiring harness shown is attached securely 3 Connect the factory installed wiring harnesses to the control panel as shown 4 Secure the control panel to the top of the stove with two sheet metal screws ...

Page 5: ...GE PROTECTOR IS REQUIRED THIS UNIT MUST BE PLUGGED INTO A 110 120V 60 HZ GROUNDED ELECTRICAL OUTLET DO NOT USE AN ADAPTER PLUG OR SEVER THE GROUNDING PLUG DO NOT ROUTE THE ELECTRICAL CORD UNDERNEATH IN FRONTOF OR OVERTHE HEATER DO NOT ROUTE THE CORD IN FOOTTRAFFIC AREAS OR PINCH THE CORD UNDER FURNITURE CAUTION BURNING FUEL CREATES CARBON MONOXIDE AND CAN BE HAZARDOUS TO YOUR HEALTH IF NOT PROPERL...

Page 6: ...ellet stove has been tested and listed for installation in residential mobile home in accordance with the clearances given below For safety reasons please adhere to the installation clearances and restrictions Any reduction in clearance to combustibles may only be done by means approved by a regulatory authority E Side Wall to Stove 8 235 mm F Side Wall to PL Vent Pipe 10 254 mm G Back Wall to Sto...

Page 7: ...ecurely fastened Outside Air is mandatory for mobile home installation See Outside Air Supply section and your dealer for purchasing Check with your local building officials as other codes may apply VENTING REQUIREMENTS WARNING INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE DO NOT INSTALL A FLUE DAMPER IN ...

Page 8: ...em must be fastened by at least 3 screws and all joints must be sealed with Hi Temp RTV silicone sealant to be airtight The area where the vent pipe penetrates to the exterior of the home must be sealed with silicone or other means to maintain the vapor barrier between the exterior and the interior of the home Vent surfaces can get hot enough to cause burns if touched by children Noncombustible sh...

Page 9: ...l ground level is reached With this installation you have to be aware of the snowdrift line dead grass and leaves We recommend a 3ft 0 91m minimum vertical rise on the inside or outside of the house The through the wall installation is the least expensive and simplest installation Never terminate the end vent under a deck in an alcove under a window or between two windows We recommend Simpson Dura...

Page 10: ...s A 6 venting system You must have the existing chimney system cleaned and or inspected by a qualified chimney sweep before proceeding with the installation of your pellet stove 2 To the right is an example of an installation using part number 860001 3 6 transition into 6 connector pipe the illustration is only an example Please conform to any local building codes or regulations having jurisdictio...

Page 11: ...two digit display indicate the mode of operation Manual or T Stat The stove has to be in normal operation to be switched from Manual to T Stat mode Manual mode operates according to the 5 set levels of feed on the bar graph from heat range 1 to heat range 5 T Stat mode works as follows The stove has a built in Thermostat into the controls of the appliance The temperature sensor for the T Stat is l...

Page 12: ...T FUEL INSTITUTE PFI Your pellet stove is designed to burn premium hardwood pellets that comply with the Pellet Fuels Institute PFI standard minimum of 40 lbs density per cubic ft 1 4 to 5 16 diameter length no greater than 1 5 not less than 8 200 BTU lb moisture under 8 by weight ash under 1 by weight and salt under 300 parts per million Pellets that are soft contain excessive amounts of loose sa...

Page 13: ...ts to the burn pot by hand NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this Avoid placing items on the stovetop during this period because the paint could be affected Attempts to achieve heat output rates that exceed heater design specifications can result in permanent dama...

Page 14: ...VERFILL HOPPER TAMPER WARNING This wood heater has a manufacturer set minimum low burn rate that must not be altered It is against federal regulations to alter this setting or otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual SHUTDOWN PROCEDURE WARNING NEVER SHUT DOWN THIS UNIT BY UNPLUGGING IT FROM THE POWER SOURCE Turning your stove off is a m...

Page 15: ...e burn pot and the area inside the burn pot housing In particular it is advisable to clean out the holes in the burn pot to remove any build up that may prevent air from moving through the burn pot freely Heat Exchanger There is a clean out plate on both sides of the heat exchanger that need to be removed to clean fly ash out of the heat exchanger The cleanouts are located inside the cabinet doors...

Page 16: ...e A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professionally inspected cleaned and if necessary repaired To clean the chimney disconnect the vent from the stove GLASS We recommend using a high quality glass cleaner Should a buildup of creosote or carbon accumulate you may wish to use 000 steel wool and water to clea...

Page 17: ... chimney joints are in good working order and sealing properly to ensure unintended exposure It is recommended that you use both smoke and CO monitors in areas having the potential to generate CO CHECK CLEAN THE HOPPER Check the hopper periodically to determine if there is any sawdust fines that is building up in the feed system or pellets that are sticking to the hopper surface Clean as needed DO...

Page 18: ...Chambers Vacuumed Combustion Blower Blades Vacuumed Brushed Convection Blower Impeller Vacuumed Brushed Vent System Cleaned Gaskets Inspected Glass Wiped Cleaned Hopper end of season Empty Vacuumed For Parts Assistance Call 800 750 2723 Ext 5051 or Email parts usstove com The information in this owner s manual is specific to your unit When ordering replacement parts the information in this manual ...

Page 19: ...ose the slide about 1 4 after your stove cools down Restart your stove If your display shows E1 again close the slide another 1 4 and restart The convection blower is overheating and tripping the internal temperature shutoff Clean any dust off of the windings and fan blade If oiling the blower does not help the blower may be bad The stove is being left on the highest setting for extended periods o...

Page 20: ...Combustion blower failure With the stove on check to see if the combustion blower is running If it is not you will need to check for power going to the combustion blower It should be a full current If there is power the blower is bad If there is not make sure the control board is sending power to the air switch Control board not sending power to combustion blower If there is no current going to th...

Page 21: ...emove the two bolts that hold the auger bracket to the auger tube The auger bracket will now be able to be removed form the auger tube Remove the two bolts on the side of the auger tube to remove the lower bearing of the auger Pull the auger out of the tube to free the jam The auger motor has failed Remove the auger motor from the auger shaft and try to run the unit If the motor will turn the shaf...

Page 22: ...rating the unit be sure the hopper lid is closed so that the hopper safety switch will activate Check the wires leading from the hopper safety switch to the control panel and auger motor for secure connections Use a continuity tester to test the hopper safety switch replace if necessary The auger shaft is jammed Start by emptying the hopper Then remove the auger motor by removing the auger pin Rem...

Page 23: ...o The Home Possible Causes Possible Remedies Unplug stove first when possible There is a leak in the vent pipe system Inspect all vent pipe connections Make sure they are sealed with RTV silicone that has a temperature rating on 500 degree F or higher Also seal joints with UL 181 AP foil tape Also make sure the square to round adapter piece on the combustion blower has been properly sealed with th...

Page 24: ...ve caused a jam Loose wire or connector Check all wires and connectors that connector to the auger motor high limit switch and the Molex connector Bad control board If the fuse is good the wires and connectors check out good and the high limit switch did not trip test for power going to the auger motor If there is not a full current going to the auger motor when the fuel feed light is on you have ...

Page 25: ...al Burnpot holes are blocked Remove the burnpot and thoroughly clean it Blockage in air intake pipe Visually inspect the air intake pipe that leads into the burnpot for foreign material Combustion blower is not spinning fast enough Test the RPM on the blower after the blades have been cleaned The RPM should be approximately 3000 RPM Bad Pellets Applies to GLASS SOOT S UP AT A VERY FAST RATE Only T...

Page 26: ...ver Gasket 2 8 80630 Housing PCBA Controller 1 9 80631 Power Board 1 10 80491 Microswitch 1 11 80709 Room Blower 1 12 88347 High Temp Snapdisc Gasget 2 13 80601 High Temp Snapdisc Air 1 14 80599 T Disc Exhaust 1 15 80872 Exhaust Blower 1 16 80871 Drive Motor 3 8 RPM 1 17 88166 Gasket Exhaust Blower 1 18 80549 Vacuum Switch 1 19 80869 Ceramic Ignitor 1 20 88118 Ignitor Flange Gasket 1 IN ORDER TO M...

Page 27: ... 2022 United States Stove Company 27 1 25A 250V FUSE 7 5A 250V FUSE CORRECT WRONG Ensure the wires are connected to the bottom two prongs of the hopper switch as shown WIRING DIAGRAM ...

Page 28: ...28 2022 United States Stove Company NOTES ...

Page 29: ...___ Engineer Name ______________________________________ License No _________________________________________ Company ____________________________________________ Telephone No _______________________________________ Stove Inspected Chimney Swept Items Replaced ______________________________________ Service 02 Date ________________________ Engineer Name ______________________________________ Licens...

Page 30: ...ted States Stove Company 27 1 25A 250V Fusible 7 5A 250V Fusible CORRECT FAUX Assurez vous que les fils sont connectés aux deux broches inférieures de l interrupteur de la trémie comme illustré SCHÉMA DE CÂBLAGE ...

Page 31: ... po 46 3 80780 Télécommande IR 1 4 893629 Pot de feu 1 5 892668 Couvercles de nettoyage des cendres 2 6 892199 Boîtier contrôleur PCBA 1 7 80491 Commutateur de couvercle 1 8 80709 Souffleur de pièce 1 9 88347 T Disc joint d air ambiant 1 10 80601 T Disc air ambiant 1 11 80599 T Disc échappement 1 12 80872 Souffleur d échappement 1 13 80871 Moteur de tarière 1 14 88166 Joint ventilateur d échappement 1...

Page 32: ...e ou le lot de granulés utilisés est peut être de mauvaise qualité Si possible essayez une autre marque de granulés Essayez aussi une marque composée d un autre type de bois résineux plutôt que feuillus Des bois différents présentent des caractéristiques différentes qui affectent la combustion L interrupteur de surchauffe se déclenche tout le temps Causes possibles Solutions possibles Débranchez le po...

Page 33: ... arbre de la tarière et essayez de le faire fonctionner Si le moteur tourne c est l arbre qui est coincé sur quelque chose Si le moteur ne tourne pas il est défectueux Tarière bloquée Commencez par vider la trémie Puis retirez le moteur de la tarière en retirant la goupille de la tarière Retirez la plaque d inspection de l arbre de la tarière dans la trémie pour pouvoir examiner l arbre de la tari...

Page 34: ...Le tableau de commande n envoie pas de courant à l allumeur Vérifiez la tension qui arrive à l allumeur lors du démarrage Ce doit être la tension nominale Si la tension est inférieure à la valeur nominale vérifiez le câblage Si le câblage est bon c est le tableau qui est défectueux UNE ODEUR DE FUMÉE EST REFOULÉE DANS LA PIÈCE Causes possibles Solutions possibles Débranchez le poêle avant toute ch...

Page 35: ... pour permettre à l interrupteur de sécurité de la trémie de s activer Vérifiez le branchement des fils qui partent de l interrupteur de sécurité de la trémie jusqu au tableau de commande et au moteur de la tarière Utilisez un testeur de continuité pour tester l interrupteur de sécurité de la trémie remplacer le si nécessaire L arbre de la tarière est coincé Commencez par vider la trémie Puis reti...

Page 36: ...ie Retirez ensuite le moteur de la tarière en retirant la goupille de la tarière puis retirez les deux boulons qui fixent le support de tarière au tube de tarière Vous pouvez maintenant retirer le support du tube de tarière Retirez les deux boulons du côté du tube de tarière pour déposer le roulement inférieur de la tarière Tirez sur la tarière pour la sortir du tube afin de lever le blocage Le mo...

Page 37: ... Panne du ventilateur de combustion Lorsque le poêle est en marche vérifiez si le ventilateur de combustion est en fonctionnement Sinon vérifiez l alimentation électrique du ventilateur de combustion Ce doit être la tension nominale Si l alimentation électrique est bonne c est le ventilateur qui est défectueux Si l alimentation est absente reportez vous au point No 8 Le tableau de commande n envoi...

Page 38: ... poêle Si votre écran affiche à nouveau E1 fermez la glissière de 1 4 et recommencez Le ventilateur de convection surchauffe et déclenche l arrêt de température interne Enlevez la poussière des bobinages et pales de ventilateur Si le graissage du ventilateur ne suffit pas il se peut que le ventilateur soit défectueux Le poêle est demeuré sur le réglage le plus élevé pendant de longues périodes En cas d...

Page 39: ...ropriétaire sont spécifiques à votre appareil Lors de la commande de pièces de rechange les informations contenues dans ce manuel vous aideront à vous assurer que les bons articles sont commandés Avant de contacter le service client notez le numéro de modèle et le numéro de série de cet appareil Cette information se trouve sur l étiquette de certification apposée à l arrière de l appareil D autres...

Page 40: ...SEZ PAS de nettoyants abrasifs N effectuez PAS le nettoyage lorsque la vitre est CHAUDE N essayez pas de faire fonctionner l appareil avec du verre brisé Le verre de remplacement peut être acheté auprès de votre revendeur américain Stove Si le verre est brisé suivez ces procédures de retrait 1 Retirez les quatre vis et les retenues en verre 2 Tout en portant des gants en cuir ou tout autre gant ada...

Page 41: ...age Pour nettoyer la cheminée déconnecter l évacuation du poêle CENDRES VOLANTES Elles s accumulent dans la portion horizontale du conduit d évacuation Bien qu elles ne soient pas combustibles elles peuvent gêner le flux normal d évacuation Elles doivent donc être périodiquement éliminées ENLÈVEMENT ET ÉLIMINATION DES CENDRES AVERTISSEMENT LAISSEZ LE POÊLE REFROIDIR AVANT D EFFECTUER TOUT ENTRETIE...

Page 42: ...nférieurs de l échangeur de chaleur Pour accéder à ces outs propres vous devez retirer les deux panneaux latéraux Les sorties propres sont fixées à la chambre de combustion avec 2 vis 5 16 Retirez les feuilles propres et aspirer les cendres accumulées Cela devrait être fait au moins une fois par mois ou plus fréquemment si de grandes quantités de cendres sont remarqués lors du nettoyage ou si le p...

Page 43: ... EN DESSOUS DE 1 4 PLEINE AVERTISSEMENT GARDEZ LE COUVERCLE DE LA TRÉMIE FERMÉ À TOUT MOMENT SAUF PENDANT LE REMPLISSAGE NE REMPLISSEZ PAS TROP LA TRÉMIE AVERTISSEMENT DE SABOTAGE Ce poêle à bois a un taux de combustion faible minimum défini par le fabricant qui ne doit pas être modifié Il est contraire à la réglementation fédérale de modifier ce paramètre ou d utiliser ce radiateur à bois d une m...

Page 44: ...surez vous que le pot de combustion ne contient pas de granulés N ouvrez PAS la porte de visualisation Il se peut que le registre doive être fermé pendant le démarrage N ajoutez PAS de granulés dans le pot de combustion à la main REMARQUE Au cours des premiers incendies votre poêle émettra une odeur lorsque la peinture à haute température durcit ou deviendra assaisonnée au métal Le maintien de pet...

Page 45: ...articules L interdiction de la combustion de ces matériaux n interdit pas l utilisation des démarreurs de feu fabriqués à partir de papier de carton de sciure de cire et substances similaires dans le but de déclencher un incendie dans un poêle à bois affecté Brûler ces matériaux peut entraîner la libération de fumées toxiques ou de rendre l appareil de chauffage de la fumée inefficace et cause CARBURA...

Page 46: ...e production de chaleur changent progressivement sur le diagramme en barres passant du niveau 1 au niveau 5 de chauffage C Touche C F La touche C F fait passer l affichage à deux chiffres des degrés Celsius aux degrés Fahrenheit et vice versa D TOUCHE mode M T Le Mode de fonctionnement du poêle peut être Manuel ou commandé par un Thermostat Des diodes distinctes à gauche de l écran à deux chiffres indi...

Page 47: ... par un ramoneur qualifié avant de procéder à l installation de votre poêle à granulés 2 Vous trouverez ci dessous des exemples d installations utilisant le numéro de pièce 860001 transition de 3 à 6 pouces vers un tuyau de connecteur de 6 pouces les illustrations ci dessous ne sont que des exemples Veuillez confirmer à tous les codes du bâtiment locaux ou ragulations ayant compétence avant de deman...

Page 48: ... 1 22 m pour rendre le système plus stable Si vous vivez dans une région où la neige est abondante il est recommandé que la sortie de l installation se trouve à plus de 3 pi 0 91 m pour échapper à la ligne de congère Cette même installation peut être utilisée si le poêle se trouve sous le niveau du sol en ajoutant simplement la section de nettoyage et un tuyau vertical à l intérieur jusqu au nivea...

Page 49: ...duit d évacuation pour poêle à granulés est conçu pour être démonté aux fins de nettoyage et doit être vérifié plusieurs fois au cours de la saison de chauffage Le conduit d évacuation pour poêle à granulés n est pas fourni avec l appareil et doit être acheté séparément INSTALLATION DE L EVACUATION POUR POELE A GRANULES L installation doit comprendre un T de nettoyage pour permettre la collecte des...

Page 50: ...1 mm et doit dépasser d au moins 36 po 914 mm au dessus de la faîtière de la maison mobile elle doit être installée avec un pare feu de plafond et un chapeau anti pluie homologués UL En cas de déplacement de la maison mobile toutes les sorties extérieures doivent être déposées pendant ce déplacement Après la réimplantation toutes les sorties extérieures doivent être réinstallées et refixées Une pr...

Page 51: ...o mm A Retour à Cuisinière U S A 1 26 CAN 8 204 B Côté poêle U S A 6 153 CAN 8 204 C De l avant au poêle U S A 6 153 CAN 8 204 D Retour à Flue 2 51 DÉGAGEMENTS Votre poêle à granules a été testé et répertorié pour une installation dans une maison résidentielle et mobile conformément aux dégagements indiqués ci dessous Pour des raisons de sécurité veuillez respecter les dégagements et restrictions ...

Page 52: ... PASSAGE ET NE LE COINCEZ PAS SOUS LES MEUBLES ATTENTION ATTENTION LA COMBUSTION DU COMBUSTIBLE GÉNÈRE DU MONOXYDE DE CARBONE QUI PEUT S AVÉRER DANGEREUX POUR LA SANTÉ EN L ABSENCE D UNE VENTILATION APPROPRIÉE ATTENTION UN DÉTECTEUR DE FUMÉE FONCTIONNEL DOIT ÊTRE INSTALLÉ DANS LA PIÈCE OÙ SE TROUVE LE POÊLE INSTALLEZ UN DÉTECTEUR DE FUMÉE À CHAQUE ÉTAGE DE VOTRE MAISON EN CAS D INCENDIE ACCIDENTEL...

Page 53: ... comme illustré 2 Déballez les meilleurs contrôles de montage et de veiller à ce que le faisceau de câblage illustré est fixé 3 Connecter les installés en usine faisceaux de câblage sur le panneau de commande comme indiqué 4 Fixez le panneau de commande au dessus du poêle avec deux vis à tôle POUR LE SERVICE À LA CLIENTÈLE APPELER 800 750 2723 EXT 5050 ...

Page 54: ...non date d inspection du système de ventilation existant ___________________________________________________________________ MISE EN SERVICE Confirmer l installation du tapis de foyer conformément aux instructions d installation Confirmer le bon placement des pièces internes Vérifier la solidité du joint de porte et des joints de porte Confirmer les dégagements aux combustibles selon les instructi...

Page 55: ... du poêle à bois USSC 5710 XH Cet appareil de chauffage respecte les limites d émission de bois de berceau de l Environmental Protection Agency des États Unis de 2020 pour les appareils de chauffage au bois vendus après le 15 mai 2020 Dans des conditions d essai spécifiques ce radiateur a fourni de la chaleur à des taux variant de Dans des conditions d essai particulières il a été démontré que ce ré...

Page 56: ...allation de ce radiateur Contactez les responsables locaux du bâtiment ou des pompiers pour connaître les permis les restrictions et les exigences d installation dans votre région NE JAMAIS UTILISER CE PRODUIT SANS SURVEILLANCE MISE EN GARDE Veuillez lire l intégralité de ce manuel avant d installer ou d utiliser votre nouveau radiateur Le non respect des instructions peut entraîner des dommages m...

Reviews: