background image

www.Volumatic.com

  

                                   25-201679 CE Advanced Configuration Manual Issue 4.0 Feb 2011 

 Page 1 of 6 

 

 

CountEasy 

Advanced Configuration Manual 

 

The CountEasy advanced configuration options affect the function and operation of the machine.  They are options that 
are not normally required to get CountEasy working but do allow for more detailed configuration to be carried out as 
well as providing future proofing features. 

 

It is not advisable to change any of the settings of the CountEasy advanced configuration unless you fully 
understand the instructions and the implications of changing each option.  
This document refers to software version CE2.6 and above. (Shown momentarily upon switch on) 

 

ENTERING ADVANCED SETUP LEVEL 2 

 
 

Press and hold down the              (

down)

 button and the            button at the same time for about 4-5 seconds.  

 

The screen will momentarily display ‘SETUP’ and will then read ‘GRAMS?’  

 
 

Now press and hold down the              (

down)

 button and the             button at the same time again for about 4-5  

 
 

seconds.  The screen will momentarily display ‘SETUP 2’ and will then read ‘GRAMS?’  

 

FINDING YOUR WAY AROUND SETUP 

 

 

To move between the options use the           button. 

 
 

To select an option use the             button. 

 
 

To move back an option or to leave Setup use the             button.         

 
 

It is important that you understand the function of the above keys whilst in Setup.

 

 
The options available in Setup Level 1 are explained in detail in the Configuration Manual provided with your 
CountEasy

 

.  

 

Setup Level 1 options are as follows: 

-

 

GRAMS? 

-

 

OPTIONS? 

-

 

CALIBRATE PACKS? 

-

 

CALIBRATE CUP?

 

 

A copy of the configuration Manual can be found on the Volumatic website 

www.volumatic.com

 

 
COUNTEASY ADVANCED SETUP LEVEL 2 OPTIONS 

In addition to the Setup Level 1 options as detailed above, the Setup level 2 options are as follows: 

-

 

NOTE ENABLE? 

-

 

NOTE WEIGHT? 

-

 

COIN ENABLE? 

-

 

COIN WEIGHT?

 

-

 

PACK SIZE? 

-

 

PACK TOLERANCE? 

-

 

SET ONLINE? 

-

 

CALIBRATE 500g? 

-

 

RESET OPTIONS? 

-

 

LOAD CURRENCY? 

 
 
 
 
 
 

ESC 

Summary of Contents for CountEasy

Page 1: ...arily display SETUP and will then read GRAMS Now press and hold down the down button and the button at the same time again for about 4 5 seconds The screen will momentarily display SETUP 2 and will then read GRAMS FINDING YOUR WAY AROUND SETUP To move between the options use the button To select an option use the button To move back an option or to leave Setup use the button It is important that y...

Page 2: ...d denomination is displayed Use the button to select either ON OFF or NO SCROLL and then press the button to select the option required To move back to the main menu options press the button NOTE WEIGHT This menu option allows you to adjust each individual note centre weight through the keyboard within the range 0 500g and 9 999g It is important to note that if the centre weight is changed the int...

Page 3: ...isting coin weights and for new coin weights to be set up To enter COIN WEIGHT press the button when the display reads COIN WEIGHT Use the button to scroll through the denomination options available To select to change the weight of a coin denomination press the button when the required denomination is displayed Use the button to adjust the coin weight to the required setting and then press the bu...

Page 4: ... online mode whereby it will communicate with a host computer This option is as standard set to OFF and should not be changed without first consulting with the CountEasy helpdesk the number for which can be found on the label on the underneath of the machine CALIBRATE 500g This menu option allows CountEasy to be completely recalibrated using a calibrated 500g weight or two full bags of 20p s that ...

Page 5: ...p or alternate weighing vessel containing the 20p s from the machine s hod and then press the button to OK The screen will momentarily read DONE and will then read 500 g OK Press the button to skip this prompt Now recalibrate the FlexiCup or alternative weighing vessel and all other packs used refer to the CountEasy Configuration Manual supplied with the machine and then test the machine again If ...

Page 6: ...to count Sterling to count Euros It is important that you are aware that loading a currency will destroy any learning that has taken place any pack calibration that has been done and any changes that have been carried out to center weights and note and coin enables LOAD CURRENCY however does not affect the OPTIONS settings or the calibration of the CUP To enter LOAD CURRENCY press the button when ...