Installation Instructions
6211/6211DS Electric Strike
®
Notes:
Deadbolt will not function with this strike.
Check with factory for retrofit applications.
1.
For lock or device preparation, see their directions.
2.
Prepare frame for strike (see other side).
3.
Wire strike (Figure 1). (Switches on 6211DS only.)
4.
Install insert for auxiliary bolt operation (Figure 2).
5.
Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.
Fail safe (FS) lip locks. Figure 1 shows status of switches.
6.
Install strike with two #12-24 screws. Make sure clearance
between latch bolt and strike lip is 1/32” (Figure 3). If not,
uninstall strike, adjust (Figure 4), and reinstall.
7.
If latch bolt does not extend far enough to actuate tripper,
install extension (Figure 5). (Tripper on 6211DS only.)
8.
Test door: With strike unlocked, door opens with latch bolt
extended. When door closes, latch bolt rides over strike lip.
931227_00(8) Copyright © 2004 Ingersoll-Rand. All rights reserved.
89/336/EEC
Figure 1
DC input is
nonpolarized
NOTE
!
J1
P1
P1 J1A
P1A
SO-12 or SO-24
12 VDC
or
24 VDC
12 VAC SO-12 12 VDC
or
24 VAC SO-24 24 VDC
{
{
Wiring
for DC
supply
Wiring
for AC
supply
Solenoid
Use crimp
connectors to
splice field wiring
to P1 leads
Figure 2
Fit hook on insert
into notch on
faceplate
Alternate insert
position
Yellow solenoid wires: 12 VDC, 0.57 A
Black solenoid wires: 24 VDC, 0.29 A
(also shown on strike label)
SOLENOID POWER REQUIREMENTS
Use crimp connectors to
splice field wiring to P2
leads; insulate unused leads
Switches hown with tripper
depressed, strike lip closed and locked
(switches and tripper on 6211DS only)
J2
Fail safe (FS)
J2
Fail secure (FSE)
S1
S2
1
2
3
4
5
6
S1
S2
1
2
3
4
5
6
Standard: 5 A, 30 VDC
Gold: 0.25 A, 30 VDC
SWITCH RATINGS
}
P2
Red (C)
Blue
Yellow
White (C)
Gray
Violet
}
S1
(monitors
tripper)
S2
(monitors
strike lip)
J2 P2
Figure 4
To adjust strike, loosen screws
A, B,
and
C
and move backbox
sideways as necessary
A
D
B
C
For more
adjustment,
move screw
A
to hole
D
Figure 3
Top view;
faceplate not
shown for clarity
1/32”
Latch bolt
Strike lip
Tripper
Figure 5
Extension
Single Door Mortise or Cylindrical Application
931227-00