background image

Installation Instructions

VON DUPRIN

6211WF/6211WFDS Electric Strike

®

Figure 1

DC input is

nonpolarized.

NOTE

!

J1

J2 P2

Switches shown with tripper

depressed, strike lip closed and locked

(switches and tripper on 6211WFDS only)

Use crimp connectors to

splice field wiring to P2

leads; insulate unused leads

P1

P1 J1A

P1A

SO-12 or SO-24

12 VDC

or

24 VDC

12 VAC            SO-12     12 VDC

     or

24 VAC            SO-24     24 VDC

{

{

J2

Fail safe (FS)

J2

Fail secure (FSE)

S1

S2

1
2
3
4
5
6

S1

S2

1
2
3
4
5
6

Wiring

for DC

supply

Wiring

for AC

supply

4.

Test strike: Apply solenoid power. Fail secure (FSE) lip unlocks.

Fail safe (FS) lip locks. Figure 1 shows status of switches.

5.

Install strike with two #12-24 screws. Make sure clearance

between latch bolt and strike lip is 1/32” (Figure 2). If not,

uninstall strike, adjust (Figure 3), and reinstall.

6.

If latch bolt does not extend far enough to actuate tripper,

install extension (Figure 4). (Tripper on 6211WFDS only.)

7.

Test door: With strike unlocked, door opens with latch bolt

extended. When door closes, latch bolt rides over strike lip.

931218_00(6) Copyright © 2000 Ingersoll-Rand Company. All rights reserved.

Solenoid

89/336/EEC

Standard: 5 A, 30 VDC

Gold: 0.25 A, 30 VDC

SWITCH RATINGS

}

P2

Red (C)
Blue
Yellow
White (C)
Gray
Violet

}

S1

(monitors

tripper)

S2

(monitors

strike lip)

Use crimp

connectors to

splice field wiring

to P1 leads

Notes:

Deadbolt will not function with this strike.

Check with factory for retrofit applications.

1.

For lock or device preparation, see their directions.

2.

Prepare frame for strike (see other side).

3.

Wire strike (Figure 1). (Switches on 6211WFDS only.)

Tripper

Figure 4

Extension

Figure 2

Top view;

faceplate not

shown for clarity

1/32”

Latch bolt

Strike lip

Yellow solenoid wires = 12 VDC, 0.57 A

Black solenoid wires = 24 VDC, 0.29 A

(also shown on strike label)

SOLENOID POWER REQUIREMENTS

Figure 3

To adjust strike,

loosen screws 

A, B,

and 

C

 and move

backbox sideways

as necessary