background image

 

Ceramic Master E20 en v1 

 

  1 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
CeramicMaster   
E20

 

 
 
 

 
 
 

 

 
 
 
 

USER MANUAL 

 

 

Summary of Contents for CeramicMaster E20

Page 1: ...Ceramic Master E20 en v1 1 CeramicMaster E20 USER MANUAL ...

Page 2: ...TICAL USE Description of buttons Description of indication Parameters and Programming Description of parameters in order of their appearance 6 ERRORS AND FOLLOWING ACTIONS 7 IMPORTANT PRACTICAL INFORMATION 8 TECHNICAL DATA 9 AUTOCALIBRATION 10 USER SOFTWARE 11 MAINTENANCE 12 SCOPE OF DELIVERY WARRANTY 3 4 5 6 7 7 8 9 10 12 13 14 15 16 16 16 ...

Page 3: ... purchased separately For more information see section 9 AUTOCALIBRATION However inappropriate use may damage the equipment and be harmful to personnel Please observe the relevant safety instructions and read the Operating Instructions carefully We wish you pleasant and fruitful work with the CERAMICMASTER E20 USING SYMBOLS This symbol indicates that there is high dangerous tension under the bonne...

Page 4: ...alter the device the notices and stickers must be kept in good condition so that they are easily readable they should not be removed the machine must not function in case of being damaged and in position to injure the staff or a third person keep the cables out of heat oil and coarse objects do not catch the device by the cable when you move it switch off the furnace and pull out the plug of the f...

Page 5: ...mic table 3 Lift table 4 Cooling pad 5 Front panel 7 Mains switch 8 Mains fuses 8А 250V 9 Plug of power cord 10 Plug of pump s power cord 11 Fuse for vacuum pump 1 25А 250V 12 Nozzle of pump s hose 13 Hose of the vacuum pump 14 Adapter 15 Vacuum pump 1 2 3 4 5 10 11 12 9 8 7 14 15 16 ...

Page 6: ...he net switch is on the rear panel on the right Put the furnace in a position which enables its easy engaging turning off from the master switch as well as from the contact You can set the duration of the sound signaling at the end of the program For this purpose it is necessary to perform the following Turn off the furnace Press RUN and STOP keys simultaneously Hold the buttons until the next mes...

Page 7: ...ps the movement of the table at any position cancels all changes of the chosen parameter in a programming mode recovers the normal working mode of the furnace after error closes manually the furnace The button can increase decrease the chosen parameter value with 100 by pressing it while turning the multi functional rotary knob opens manually the furnace The button can increase decrease the chosen...

Page 8: ... depth of the vacuum in Sector C Indicates the current temperature in the chamber The LINE 2 shows following information Sector MODE displays information of the current stage Sector PROGRAM NAME shows the name of the selected program Indicator 1 the furnace is in the phase of drying Indicator 2 the furnace is in the phase when the tempera ture increases to the value for firing Indicator 3 the furn...

Page 9: ... in order to chose the parameter you want to change Press button RUN in order to chose the value of the parameter you want to change If you have chosen the first parameter you would see on the display XXX YYYYYYYYYY SET PROGRAM NAME Indicator of the button RUN turns off and the red indicator on the button STOP begins to blink Turn the MFRK to change the parameter value Press button STOP in order t...

Page 10: ...nged from 0s to 1h increase rate of the temperature for the firing Its value is from 30 C min to 200 C min increase rate of the temperature for the firing Its value is from 30 C min to 200 C min time for maintaining the temperature FIRE TEMP It can be changed from 0s to 30min during this time the table is about 1cm from the upper end position It can be changed from 0s to 1h time for opening the fu...

Page 11: ...ows the value of the parameter FIRE RATE and by MFK the programmed value can be changed If you do not respond within the next three seconds the display shows the current stage of program execution In the same way by pressing the ESC key can be changed parameter FIRE TEMP and by button you can change the parameter FIRE TIME When programming the temperature conditions for parameters IDLE TEMP DRY TE...

Page 12: ...lower than 5 С 53 the drying sensor is not reached for a certain time when the furnace opens 78 the lower sensor is not reached for a certain time when the furnace opens 83 the top sensor is not reached for a certain time when the furnace closes and a program with vacuum executes 90 it is not possible to reach the sensor for top position 91 it is not possible to reach the sensor for lower position...

Page 13: ...er turning on the furnace run at least one program with an empty camera and wait another 20 minutes 7 If the power supply is interrupted during the working process and a If the temperature in the chamber has not decreased by more than 15 degrees the current program will continue from the stage at which it has been stopped b If the temperature in the chamber has decreased by more than 15 degrees th...

Page 14: ...ice is designed for usage in normal dental premises up to 2000 m altitude above sea level 13 The maximum relative humidity of the air must be 80 for temperatures up to 31 С decreasing lineally to 50 relative humidity for temperature 40 С 14 Working modes 14 1 Programming mode Programming of the parameters is fully described in chapter 7 PROGRAMMING 14 2 Working mode It shows the number of the exec...

Page 15: ...ating coefficient was outside the normal range the display shows Err Bad value KKKKK TTTTT RRR AAAAA Where ККККК is the wanted coefficient ТТТТ Т is the temperature at break RR R is the ambient temperature ААААА is the value measured by ADC the normal range of the coefficient is between 10000 and 12000 If during the execution of the program there was no problem and autocalibration has proceeded no...

Page 16: ...ents Change the safety locks with the announced valus only namely 1 25A slow class T 8A slow class T No repair activity by a service technician who is not authorized by the manufacturer is allowed The lifting and carrying should be made only with the both hands from below as the furnace stands on end No carrying and transportation in another state except for vertical position is allowed Furnace CE...

Page 17: ...ter E20 WARRANTY SHEET VOP Ltd warrants the consumer for proper operation of all parts and materials in this product during a period of 12 months since the day of its purchase During this period VOP Ltd or its authorized persons will repair on its own account all defects which have occur during the normal operation of the machine Defects caused by improper transportation storage and manipulation o...

Reviews: