STEP
Fill fry tank with oil and
then turn power on
1
STEP
Programming modES
2-7
www.VulcanHart.com • Fryer Technical Support: 1-800-814-2028
To SToP a TimEr oncE ThE counTdown SEquEncE haS STarTEd:
Press and hold the timer
button until timer is reset and
flashing light goes OFF.
LEFT TIMER
BUTTON
RIGHT TIMER
BUTTON
LEFT
RIGHT
LIGHTS
F-32912 (January 2007)
To
unLocK
this control you
must quickly press the
buttons while the
word ‘LocKEd’ is
displayed
LEFT LEFT righT righT
unLocK codE
Programming in 7 Easy Steps
(for revisions V3.00 or higher)
Display will scroll through VULCAN
➤
FRYERS
➤
Rev. No.
➤
MELT CYCLE LIQUID
SoLid STaTE conTroLS guidE
Vulcan
Fryers
TEMPERATURE SETTING
displays
Press
LEFT
to increase temp.
Press
RIGHT
to decrease temp.
Press
to go to Step 5.
RIGHT TIMER
displays
Press
LEFT
to increase time.
Press
RIGHT
to decrease time.
Press
to go to Step 4.
Display shows
ACTUAL TEMPERATURE
MELT CYCLE
displays
Press
LEFT
to change to
“S”
Solid.
Press
LEFT
to change to
NO MELT
.
Press
LEFT
to change to
“L”
Liquid.
Press
to go to Step 6.
Results of programming for
oil temperature is at set
temperature
TEMPERATURE
SETTING RESULTS
Press
program button
to enter the program mode:
LEFT TIMER
displays
Press
LEFT
to increase time.
Press
RIGHT
to decrease time.
Press
to go to Step 3.
Press
button and
HOLD
FOR 3-5 seconds
to save
and exit program mode.
Note: Programming modes can
be initiated while the fryer is
ON by pressing the
button.
If ‘LOCKED’ appears refer to
‘UNLOCK’ code.
UNLOCK
displays
Press
LEFT
to
LOCK
.
Press
RIGHT
to
UNLOCK
.
Press
to go to Step 7.
Note: VULCAN recommends
keeping the controls LOCKED after
programming to prevent altering
2
3
4
5
6
7
To make changes
to your program:
1. If display is
locked it must be
unlocked using the
unlock code.
2. After unlocking
go to steps
–
2
7
oPTionaL diSPLay modES
After the program mode is completed, one
of the following screens will be displayed.
Results of programming
MELT L
MELT CYCLE RESULTS
Display says
MELT L
Results of programming
MELT S
Display says
MELT S
Results of programming
NO MELT
Display says
HEATING
if oil
temperature is below 135 º F