Man.V100 (15 Nov. 2012) 

 

 

 

 

  

VWR Standard Biological Microscope 

 

 

 
 

Operation Manual 

(Version 1.0.0) 

 

 
 
 

VWR  Standard  Biological  Microscope 

89404-882,  89404-884 

 

 

 

 

 

 
 
 

 
 
 
 

 
 
 

 
 
 

 
 
 
 

 
 
 

 
 
 

VWR Stand Monocular Microscope 

Summary of Contents for 89404-882

Page 1: ...Man V100 15 Nov 2012 VWR Standard Biological Microscope Operation Manual Version 1 0 0 VWR Standard Biological Microscope 89404 882 89404 884 VWR Stand Monocular Microscope...

Page 2: ...ginal shipping container a foam box in a fiberboard carton should be kept for use in long term storage or return shipment When unpacking please check the components according to the packing list Pleas...

Page 3: ...not be used again and contact the VWR service department or a VWR microscope repair agency to have it repaired Please be sure to turn off the power before opening the instrument to replace LED illumi...

Page 4: ...ery If any defect is found notify the manufacturer immediately Upon receipt of the Notification of Defect as described above the manufacture is responsible to solve the problem either by repairing the...

Page 5: ...t names 1 Eyepiece 7 Focusable 1 25 abbe condenser 2 Monocular head 8 Collector 3 Lock screw of eyepiece 9 Base w rechargeable batteries and external charger 4 Nosepiece 10 Head lock screw 5 4X 10X 40...

Page 6: ...osepiece 18 Stage adjustment knob Y axis 14 4X 10X 40X 100X objectives 19 Base w rechargeable batteries and external charger 15 Mechanical stage 20 Binocular head 16 1 25 condenser w iris diaphragm 21...

Page 7: ...include Built in LED illumination with brightness adjustment Cord reel at the back to accommodate power cable convenient and practical Compact and easy to use Coaxial coarse and fine focus adjustment...

Page 8: ...2 Operation of the biological microscope Put the specimen on the stage and fix it with the slide clips Never examine a prepared specimen without a cover slip Note The thickness of the cover slip must...

Page 9: ...ed for an objective a dustproof cap should be screwed into the vacancy to prevent dust from entering 4 MAINTENANCE TROUBLESHOOTING 4 1 Maintenance The biological microscope is limited to the following...

Page 10: ...ted light objective Use the standard 0 17 thick cover slip No immersion oil or non specified immersion oil for 100X oil immersion objective Use immersion oil supplied with the instrument or go to buy...

Page 11: ...0 linearly decreases to 50 Operation Permissible environment temperature Permissible relative humidity 5 40 C Below 31 C max humidity is 80 at 40 C linearly decreases to 50 Operating Parameters Protec...

Page 12: ...ide clip 1 25 condenser 120 x 120 mm 76 x 26 mm On the right On the left of movable clip Used for 4X 100X objectives Movable stage Dimension L x W Max moving range Slide clip 0 65 condenser 110 x 110...