background image

Installation and Handling Guidelines for Screw-In Vents

Part Series: PMF100318, PMF100319, PMF100320, PMF100321, PMF100391, PMF100520, PMF100444

GORE

®

 Protective Vents are designed to protect in the 

harshest environments while quickly and effectively  
equalizing the pressure in sealed enclosures. 

To  

maximize the performance of the vent for the lifetime  
of your product, please follow the handling and 
installation recommendations provided. 
  

Handling Guidelines

• Avoid direct contact with GORE

 Membrane.

• Do not remove vent cap.
• Do not over-tighten.
• It is recommended to use the following torque wrench sizes  

for installation:  
Plastic molded parts  16 mm socket or wrench 
Metal vent 

18 mm wrench   

Recommended force  0.6 – 0.8 Nm (0.44 – 0.59 lbf-ft)  

Protective Ring

Enclosure

Through-Hole

A

A

Cross Section A-A

Y

X

PolyVent/M12x1

PolyVent/M12x1.5
PolyVent/M12x1.5 HA
Metal Vent/M12x1.5

ø1

4.

3

 

± 

0.

2

60

°

ø1

0.

5

M

12

 x 

1.

5

Wall

Corehole

Center line

ø1

4.

3

 

± 

0.

2

60

°

ø1

1

M

12

 x 

1

Wall

Corehole

Center line

 

Screw-In Vents

Protective Vents

adhesive vents

To prevent unintentional damage, an additional means of protection 
is recommended at the installation site. An example of one possible 
means of protection, a protective ring, is shown below:

Installation Recommendations

 

 

 

1. Preparation

Make sure mounting surface is clean and free of oils, particles 
and other contaminants. Isopropyl alcohol can be used to clean 
the mounting surface if needed. Ensure the surface is dry prior  
to installation.  

2. Positioning

For best performance, vents should be mounted on a flat, vertical 
surface where liquids or other contaminants will not pool. 

(See  

diagram below for mounting recommendation)

. Gore molded parts 

are designed for mounting to the exterior housing wall.  

Recommended Protective Ring Dimensions by Part

 

 

PolyVent  

 

Part 

PolyVent 

M12x1.5/  

Metal Vent/ 

Description 

M12x1 

M12x1.5 HA 

M12x1.5

 

 

PMF100320 

 

 

PMF100321 

 

PMF100318          PMF100391                       

Part Number 

PMF100319 

PMF100520 

PMF100444

X dimension  

22 mm  

22 mm 

24 mm  

 

(0.866") 

(0.866") 

(0.945")

Y dimension  

9 mm 

8 mm 

15 mm 

 

(0.354") 

(0.315") 

(0.590")

Enclosure

Interior

Environment

Housing Wall 

®

 

GORE

®

Protective Vent 

GORE

Protective Vent 

3. Installation

To insert into the housing, make sure that the threads have proper 
engagement and screw into the housing. If using a socket to tighten 
vent to surface, ensure socket is fully engaged with the vent housing 
before tightening. 

4. Final Inspection 

Look over the part to ensure that the vent is properly seated. 

The Gore proprietary membrane is constructed of ePTFE and allows for the free 
passage of gases and vapors while at the same time preventing liquid and  
particulates from entering the  housing.

Recommended Housing Geometry

All dimensions are in mm.

Reviews: