background image

INSTALLATION INSTRUCTION 

InvisiLED Tunable White 

T24-TW3 

 

Waclighting.com 

Phone (800) 526.2588 

Fax       (800) 526.2585 

Headquarters/Eastern Distribution Center    

44 Harbor Park Drive  

Port Washington, NY 11050 

 

Central Distribution Center  

1600 Distribution Ct  

Lithia Springs, GA 30122  

Western Distribution Center 

1750 Archibald Ave  

Ontario, CA 91761  

 

 

  WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program

.                 OCT. 2022      

1. 

 

 

 

SAFETY INSTRUCTION 

IMPORTANT: NEVER attempt any work without shutting off the electricity. 

 

Always turn off power at fuse box prior to installation to prevent electrical shock.  

 

Intended for indoor use. Dry and damp locations.  

 

Install in accordance with national electric code, and local regulations.  

 

Consult with local inspector to assure compliance. 

 

Do not submerge or install within 5 feet of a swimming pool. 

 

Do not connect the tape directly to high voltage power 

 

CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK  

 

Read all instructions before installing.  

 

Handle product with care. 

 

Do not conceal or extend exposed conductors through a building wall 

 

To reduce the risk of fire and burns, do not install this lighting system where the exposed bare conductors can be shorted or contact any 

conductive materials 

 

To reduce the risk of overheating and potential fire risk, make sure all connections are tight. 

 

Do not install any fixture assembly closer than 6 in. from any curtain, or similar combustible material. 

 

Do not modify or disassemble product beyond instructions or warranty will be void. 

 

Failure to follow safety warnings, and installation instruction will void the warranty 

 

ATTENTION - AFIN DE RÉDUIRE LES RISQUES D'INCENDIE ET DE CHOC ÉLECTRIQUE 

 

• 

Lire toutes les instructions avant d'installer. 

• 

Manipuler le produit avec soin. 

• 

Ne pas dissimuler et faire passer les conducteurs exposés à travers un mur de bâtiment. 

• 

Afin de réduire les risques d'incendie et de brûlures, ne pas installer ce système d'éclairage là où les conducteurs dénudés peuvent être court-

circuités, ou entrer en contact avec des matériaux conducteurs. 

• 

Afin de réduire le risque de surchauffe et d'incendie potentiel, s'assurer que toutes les connexions sont bien serrées. 

• 

Ne pas installer aucun luminaire à moins de 6 pouces d'un rideau ou d'un matériau combustible similaire. 

• 

Ne pas modifier ou démonter le produit au-delà des instructions sous peine d'annuler la guarantie. 

• 

Ne pas respecter les avertissements de sécurité et des instructions d'installation annulera la garantie.  

 

             

           

             

      

        

        

         

 

  

 

 

WIRING AND INSTALLATION:

 

 

1. 

Turn Power off at circuit breaker (See FIG. 1) 

 

 

    

FIG. 1 

 

   

 

2. 

Mounting

 

24VDC Class 2 remote power supply and WAC Wireless DMX LED 

Controller at desired location.  (See FIG. 2)

 

 

    

FIG. 2 

 

   

 

 

Do not bend the tape light to 

a diameter less than 4 inches 

Do not bend the tape light 

on a horizontal plane 

Do not fold or 

twist LED Tape 

Do not cover LED tape 

light with any materials 

 

Do not power the LED 

tape while attached to the 

spool or tightly coiled 

 

Avoid contact with sharp 

objects 

Install on stable 

clean, dry surface 

Summary of Contents for InvisiLED T24-TW3

Page 1: ...closer than 6 in from any curtain or similar combustible material Do not modify or disassemble product beyond instructions or warranty will be void Failure to follow safety warnings and installation...

Page 2: ...TE BLACK BLACK BLACK FIG 3 Option B Shielded data Cable 90 ft maximum distance between power supply to the beginning of the tape A shield data cable shall be used to connect between the power supply W...

Page 3: ...e Black 4 To extend an unshielded cable length if needed In Wall Rated Joiner Cable T24 IC and Joiner Cable Extender T24 FF WT can be used to join between sections as shown in FIG 6 FIG 6 5 To extend...

Page 4: ...2300 0 2105 4 83 19 270 123 255 2400 0 1818 4 33 22 240 75 255 2500 0 1667 3 86 24 212 35 255 2600 0 1538 3 58 26 196 13 255 2700 0 1429 3 37 28 183 255 0 2800 0 1538 3 57 26 198 255 12 2900 0 1600 3...

Page 5: ...ution Center 1750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 5 In o...

Page 6: ...0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 27 1 36 1 45 1 54 1 63 1 72 1 81 3200K 0 09 0 09 0 18 0 27 0 36 0 46 0 55 0 64 0 73 0 82 0 91 1 00 1 09 1 18 1 28 1 37 1 46 1 55 1 64 1 73 1 82 3300K 0 09 0 09 0 1...

Page 7: ...inch interval The cut line is shown on both sides of connector See FIG 11 FIG 11 9 Mount InvisiLED Tunable White tape light clean surface before mounting Peel off 3M VHB adhesive backing covers off as...

Page 8: ...022 8 Tape to Tape T Connector T24 TI WT See FIG 14 Tape to Tape X Connector T24 XI WT See FIG 15 FIG 14 FIG 15 1 Tape to Tape L Connector T24 LI WT See FIG 16 Flex Tape to Tape Y Connector T24 Y WT S...

Page 9: ...750 Archibald Ave Ontario CA 91761 WAC Lighting retains the right to modify the design of our products at any time as part of the company s continuous improvement program Oct 2022 9 SYSTEM DIAGRAM Inv...

Page 10: ...less voltage drop and boost light output up Another way is to lower a maximum DMX value to reduce the current consumption to InvisiLED TUNABLE WHITE tape Thus a contrast between beginning and the end...

Reviews: