background image

Multidem - ENG - Rev 07

Instructions for use

Summary of Contents for multidem C27

Page 1: ...Multidem ENG Rev 07 Instructions for use...

Page 2: ...rms 4 2 General Information 5 3 Operating and Safety Instructions 7 4 Installation 10 5 Changing the Filter Cartridge 13 6 Capacity Tables 14 7 Repair 15 8 Troubleshooting 16 9 Technical Data 17 10 Or...

Page 3: ...s manual WARNING in the event of risk of injury to persons CAUTION in the event of risk of damage to property General comments with no risk to persons or property W H symbols Not drinking water Observ...

Page 4: ...1 Definition of Terms 4...

Page 5: ...d and controlling the water flow the innovative locking handle ensures simple and reliable operation The quality of the filter system has been inspected and confirmed by independent institutes Multide...

Page 6: ...ansport Adhere to the ambient conditions in the Technical Data Chapter 9 for storage and transport The instructions for use should be seen as part of the product and kept for the entire service life o...

Page 7: ...lity for any damage including consequential damage arising from the incorrect installation or use of the product Specific Safety Instructions Only water of drinking water quality may be used as intake...

Page 8: ...replaced Please also note the maximum usage period of 12 months for the filter cartridge Chapter 5 Table of flushing volumes following stagnation Filter cartridge Flushing volume following stagnation...

Page 9: ...age Do not assemble near sources of heat or open flames A stop valve must be installed before the filter system inlet hose If the water pressure is greater than 8 6 bar a pressure reducer must be inst...

Page 10: ...er Connection Ensure that the locking handle on the head is open Close water intake and switch off the power supply to the terminal device Fit the hoses to the water inlet IN and outlet OUT on the fil...

Page 11: ...ge date in the date field on the filter cartridge Insert the filter cartridge vertically into the filter head The filter cartridge can only be inserted when the locking handle is open Make sure that t...

Page 12: ...Installation Commissioning Open the water intake and switch on the power supply to the terminal device Operate the flush valve and flush the filter system until the filtered water runs clear and witho...

Page 13: ...e for determining the conductivity in the filtrate e g Primo 5 REF A800500X Remove the water from the flush hose for measuring purposes by actuating the flush valve In all cases the filter cartridge m...

Page 14: ...ty in litres 50 2250 100 1130 200 565 300 375 400 280 500 225 The stated capacities have been tested and calculated on the basis of common application and machine conditions External factors e g varyi...

Page 15: ...e replaced in rotation after 10 years The non return valve supplied must be replaced every 5 years Before replacing read the technical data Chapter 9 and the operating and safety information Chapter 3...

Page 16: ...pen water intake Cause Mains pressure too low Troubleshooting Check mains pressure If the fault persists check the filter system and filter cartridge and replace if necessary Cause Filter head not mou...

Page 17: ...e 4 C to 30 C 20 C to 50 C Nominal flow 60 l h Pressure loss at nominal flow 0 2 bar Bed volume 2 7 l Weight dry wet 2 7 3 9 kg Dimensions width depth height Filter system Filter head with filter cart...

Page 18: ...10 Order Numbers 18 A812018X Spray gun set A812016X Multidem C27 filter cartridge A800502X Primo 5...

Page 19: ...A812020X Connection kit 2nd sterilizer Order Numbers 19 19723110 SAT A812005X Water block safety valve A812019X 3m 6x4 mm PTFE tubing A812105X Spiral tubing A812106X Water gun...

Page 20: ...A812021X Adaptors 6 to 8 mm tubings Order Numbers 20 A812022X 3 8 Non return valve...

Page 21: ...ridges are classified as special non hazardous waste The CER number for used ion exchange resins used for the production of demineralized water is 19 09 05 The products must be disposed in accordance...

Page 22: ...Notes...

Page 23: ...LIMITED 6 Stroud Wood Business Centre Park Street St Albans Herts AL2 2NJ t 44 1727 874990 f 44 1727 874628 technical uk wh com A DEC AUSTRALIA CO INC Unit 8 5 9 Ricketty Street Mascot NSW 2020 t 61...

Page 24: ...NG Instructions for Use Rev 07 Subject to alterations 21 11 2019 Manufacturer W H Sterilization S r l Italy I 24060 Brusaporto Bg via Bolgara 2 t 39 035 66 63 000 f 39 035 50 96 988 wh com med wh com...