INSTALLATION 
A N D   O P E R AT I N G 
INSTRUCTIONS

151211-24 

PS 45 CLASSIC 

5055.5313

Contact your local building or fi re 
officials regarding permits and any 
information on installation and 
inspection requirements in your area.

TESTED and LISTED to ASTM 1509-04, 
CAN/ULC S627 AND UL 1482

IMPORTANT:
THESE INSTRUCTIONS ARE TO 
REMAIN WITH THE HOMEOWNER.
SAVE THESE INSTRUCTIONS

MODEL:
PS45 CLASSIC
SERIES: A

SAFETY NOTICE

Please read this entire manual before 
installation and use of this pellet fuel-
burning room heater. Failure to follow 
these instructions could result in property 
damage, bodily injury or even death.

WARMLAND PELLET STOVE

Summary of Contents for PS45 Classic Series A

Page 1: ...ur area TESTED and LISTED to ASTM 1509 04 CAN ULC S627 AND UL 1482 IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS MODEL PS45 CLASSIC SERIES A SAFETY NOTICE Pleas...

Page 2: ...n 12 Operation 12 Filling the Hopper 12 Control Board 12 General Operation 13 Thermostat Operation 13 Manual Mode 13 Paint Curing 13 Plated Surfaces 13 Routine Checks and Maintenance 14 Fire Pot and L...

Page 3: ...smokedetectors Ifyourlocalcoderequiresasmokedetectorbe installedwithinthesameroom youmustfollowtherequirements ofyourlocalcode Checkwithyourlocalbuilding firedepartment for requirements in your area T...

Page 4: ...tive Pressure Warning This appliance has not been designed to be operated in a negatively pressurized room Provide adequate air for combustion The stove s exhaust system works with negative combustion...

Page 5: ...pe the clinkers out Clean the holes with a small pointed object if required Refer to the section Routine Cleaning and Maintenance Wood Pellet Specifications This appliance has been designed to burn wo...

Page 6: ...n meets local building codes It is recommended that the unit be secured into its position in order to avoid any displacement Thisappliancemustbeinstalledonafloorwithan adequate load bearing capacity i...

Page 7: ...rances removal of the appliance may be necessary for servicing Recommended clearance zone from the front of the appliance to combustibles is 4 feet minimum NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Page 8: ...60 cm from the edge of the terminal E 12 inches 30 cm Clearance to unventilated soffit F 12 inches 30 cm Clearance to outside corner G 12 inches 30 cm Clearance to inside corner H 3 feet 90 cm Not to...

Page 9: ...e or odor during appliance shut down or power failure and avoid exposing people or landscaping shrubs to high temperatures Hooded vent Using existing wood vent Thru roof Recommended Recommended Recomm...

Page 10: ...e are approved however it is recommended that a minimum of 5 ft of vertical be included in the vent system Having a vertical section in the venting will help prevent smoke from exiting the appliance d...

Page 11: ...this safely all sections of listed connector offset elbows and chimney section must be screwed to gether by at least three sheet metal screws per joint The chimney must be suitably supported by the ch...

Page 12: ...rers instructions could result in a malfunction Pay special attention to the thermostat location requirements If the location requirements are not followed the appliance may operate erratically or fai...

Page 13: ...un out of pellets the auger will be empty and the Burn Pot liner will need to be primed To prime place a handful of pellets into the middle of the liner On the control board push the ON OFF button Thi...

Page 14: ...ning brush can be used to loosen any ash build up before vacuuming DONOTUSEASTANDARDHOUSEHOLDVACUUM WHEN USINGA SHOPVACUUM A FINE DUST FILTER MUST BE INSTALLED AS THE STANDARD FILTERS WILL LEAK THE FI...

Page 15: ...ut the Ash Pan enclosure before inserting the Ash Pan Fig 11 CAUTION Disposal of Ashes Ashes should be placed in a metal container with a tight fitting lid The closed container shouldbeplacedonanon co...

Page 16: ...clean out all the ash in the exhaust passages Fig 17 Fig 16 Don tforgettocleanuparoundtheheatexchanger Oncetheflue passage is clear of ash build up reinstall the Firebox Liner Fig 17 Firebox Passage C...

Page 17: ...Fig 19 Cleaning the Convection Blower To clean the convection blower remove the right cabinet side see previous page Disconnect the stove power cord from the electrical outlet Using a 3 8 wrench remo...

Page 18: ...reset button on it and will not allow the stove to start up until the reset button has been pushed Proof of Fire Snap Switch This switch is installed on the combustion blower and is used to sense when...

Page 19: ...PELLET STOVES 19 PS45 CLASSIC 151211 24 Wiring Diagram 5050 838 A 010210 PS 45 WIRING...

Page 20: ...25 1 5068 7173 VENT STARTER TUBE GASKET 26 1 PS45 7384WLD VENT STARTER TUBE 27 1 5027 171 EXHAUST TEMPERATURE SWITCH 28 1 5024 503 COMBUSTION BLOWER 29 1 PS45 7415XXX SIDE SHIELD LEFT RIGHT 30 1 PS45...

Page 21: ...PELLET STOVES 21 PS45 CLASSIC 151211 24 a a b b Components List A B...

Page 22: ...PELLET STOVES 22 PS45 CLASSIC 151211 24...

Page 23: ...PELLET STOVES 23 PS45 CLASSIC 151211 24 Rating Label...

Page 24: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD www pacificenergy net 2975 Allenby Rd Duncan BC V9L 6V8 Technical Support 250 748 1184...