The Wasp WLP 4170 CCD Scanner is ready to scan the
most popular bar codes out of the box. This manual
should only be used to make changes in the
configuration of the scanner for specific applications.
This scanner does not require software or drivers to
operate. The scanner enters data as keyboard data. Please
review this manual before scanning any of the programming
bar codes in this manual.

Tech Tip

If you are unsure of the scanner configuration or have
scanned the incorrect codes, please scan the default
bar code on page 6. This will reset the scanner to its
factory settings.

Summary of Contents for WLP 4170 CCD

Page 1: ...he scanner for specific applications This scanner does not require software or drivers to operate The scanner enters data as keyboard data Please review this manual before scanning any of the programm...

Page 2: ...ced or transmitted in any form or by any means without the written permission of Wasp Technologies The information contained in this document is subject to change without notice Wasp is a trademark of...

Page 3: ...Delay 7 3 Intercharacter Delay 8 4 Keyboard Wedge 9 5 Scanning Modes 10 6 Preamble Postamble Configuration 11 5 Bar Code Symbology 12 29 Code 39 12 13 Code 128 14 15 UPC A 16 17 UPC E 18 19 EAN 13 20...

Page 4: ...photographed digitized and electronically sampled by built in photodetectors The detectors process the measurement of every bar and space using the number of adjacent photodetectors which contrast a...

Page 5: ...yboard port Plug your keyboard cable into the other end female Din 5 of the the Wasp WLP 4170 CCD Scanner If your keyboard and PC support a Din 6 connection use the enclosed Din 5 to Din 6 converter c...

Page 6: ...CD Scanner have been pre programmed for the most common bar code configurations Use the Setup Configuration sections only to customize the Wasp settings Tip Use the pre printed Bar Code Test Symbols i...

Page 7: ...ion of a bar code is dependent on the narrowest element of a bar code X dimension and can vary from high density nominally less than 0 009 in 0 23 mm medium density between 0 009 in 0 23 mm and 0 020...

Page 8: ...ven basic steps need to be followed for each programmed setting 1 Determine what if any options on EACH PAGE that you wish to change 2 Scan the Begin bar code WLP 4170 CCD Scanner will sound an ascend...

Page 9: ...e the factory default settings if you are unsure how your scanner has been configured The Factory Default configuration is very useful when you need to reprogram your Wasp WLP 4170 CCD Scanner after t...

Page 10: ...f the WLP 4170 CCD Scanner NOTE For help in configuring these settings consult the programming steps on page 5 1 Scan Begin 2 Scan Set Beep Volume 4 Scan the Set barcode on the back cover flap 5 Scan...

Page 11: ...nner and the keyboard buffer of the computer Note The default for the intercharacter delay is set to 2ms and is the most common configuration however your PC may be different When you scan a bar code...

Page 12: ...s Lock option toggles the case sensitivity of your keyboard The Laptop No Keyboard setting should be enabled if you are connecting this scanner to a laptop or to a PC with no keyboard NOTE For help in...

Page 13: ...ng these settings consult the programming steps on page 5 Continuous Mode Trigger with 10 Sec Delay When this option is selected the LEDs are visible at all times Under this option you cannot read the...

Page 14: ...configured Data Stream Example NOTE For help in configuring these settings consult the programming steps on page 5 Begin Set Preamble Set Postamble Exit Preamble Postamble Scan Begin Scan Set Preamble...

Page 15: ...ment of Defense DOD The principal feature is to encode messages using the full alphanumeric character set Default Begin On Off Verify Check Digit Transmit Check Digit Exit Option Alpha Numeric Entry B...

Page 16: ...racters with a letter A Z to form the characters that are not present in the standard Code 39 symbology Default Set Maximum Length Set Minimum Length Begin Format Start Stop Transmission Exit Option A...

Page 17: ...OTE For help in configuring these settings consult the programming steps on page 5 Code 128 is variable length and encodes the full 128 ASCII character set Each character is represented by 11 modules...

Page 18: ...imum 00 64 00 64 Maximum 00 64 00 Standard 00 UCC EAN 128 01 NOTE For help in configuring these settings consult the programming steps on page 5 Code 128 is the most flexible of all the common linear...

Page 19: ...e two digits 01 Disable 00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 UPC A Universal Product Code A is fixed length and is the most common UPC bar c...

Page 20: ...s of the UPC A bar code are assigned from the Uniform Code Council UCC The next five digits are assigned by the manufacturer and the final digit is a modulo 10 check digit The nominal height for the U...

Page 21: ...Enable 01 Disable 00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 UPC E Universal Product Code E is fixed length and is a compressed six digit code us...

Page 22: ...settings consult the programming steps on page 5 The printed value of the UPC E code is a twelve digit code The nominal height for the UPC E bar code is one inch The reduced size is 80 of the nominal...

Page 23: ...01 Disable 00 Enable 01 Disable 00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 The EAN JAN 13 European Article Number Japanese Article Number is fixe...

Page 24: ...xed length and is similar to the UPC A symbology but encodes a 13th digit The nominal height for the EAN JAN 8 bar code is one inch The reduced size is 80 of the nominal size Default Supplement Digits...

Page 25: ...able 00 Enable 01 Disable 00 Enable 01 Disable 00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 The EAN JAN 8 is fixed length and is similar to the UPC...

Page 26: ...s 02 2 5 digits 03 or None Disable 00 Enable 01 Disable 00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 The EAN JAN 8 is fixed length and is similar to...

Page 27: ...inimum 64 00 00 00 Maximum 00 64 00 NOTE For help in configuring these settings consult the programming steps on page 5 Code 93 encodes the full 128 ASCII character set using 9 modules arranged into 3...

Page 28: ...ese settings consult the programming steps on page 5 Interleaved 2 of 5 is a variable length even numbered numeric bar code It is typically used in industrial and master carton labeling and also in th...

Page 29: ...TE For help in configuring these settings consult the programming steps on page 5 Codabar is a variable length symbology capable of encoding six special alphanumeric characters capital letters A throu...

Page 30: ...00 Enable 01 NOTE For help in configuring these settings consult the programming steps on page 5 Codabar is a variable length symbology capable of encoding six special alphanumeric characters capital...

Page 31: ...10 10 02 Mod 11 10 03 Disable 00 Enable 01 64 Minimum 64 00 00 00 Maximum 00 64 00 NOTE For help in configuring these settings consult the programming steps on page 5 MSI Plessey is a variable length...

Page 32: ...e PDF stands for Portable Data File and 417 is derived from the module structure Each PDF417 symbol consists of 3 to 90 stacked rows surrounded by a quiet zone on all four sides Each row consists of a...

Page 33: ...Setup Configuration Bar Code Test Symbols Appendix A Note Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan Use the Bar Code Symbologies config...

Page 34: ...31 UPC A UPC E UPC E w 5 digit supplement UPC E w 2 digit supplement UPC A w 2 digit supplement UPC A w 5 digit supplement Setup Configuration Bar Code Test Symbols Appendix A cont Default...

Page 35: ...EAN JAN 13 EAN JAN 13 w 2 digit supplement EAN JAN 13 w 5 digit supplement 3 Setup Configuration Bar Code Test Symbols Appendix A cont Default...

Page 36: ...EAN JAN 8 EAN JAN 8 5 w 5 digit supplement EAN JAN 8 w 2 digit supplement PDF417 33 Setup Configuration Bar Code Test Symbols Appendix A cont Default...

Page 37: ...nsor 2 048 pixel CCD array Operating Voltage 5 VDC 0 25V Current Consumption Standby 100 mA 5 VDC Sleep 25 mA 5 VDC Operating 180 mA 5 VDC MECHANICAL Dimensions W3 5 x T4 5 x H7 2 Weight 150 g without...

Page 38: ...or repair of a product is your exclusive remedy Any other implied warranty of merchantability or fitness is limited to the duration of this written warranty Some states provinces and countries do not...

Page 39: ...B 36 ASCII Code Table ASCII Preamble Postamble Code Table 00 Null 01 Up 02 Down 03 Left 04 Right 05 PgUp 06 PgDn 08 BS 09 Tab 0B Home 0C End 0D Enter 0E Insert 0F Delete 11 F1 12 F2 13 F3 14 F4 15 F5...

Page 40: ...0 1 2 3 4 5 6 7 8 9 A B C D E F FINISH BACK COVER BAR CODES...