MODELS: BVC75 & BVC100

INSTALLATION & OPERATION INSTRUCTIONS

BVC75-INST 

Rev. Jun08

TM

P/N 

120HEAD34 or 

120HEAD100

P/N 

G10105

P/N 

12010 Clear 

P/N  

BRN01

Not shown: Wrench  (P/N BWR34)

Installation Precautions

You must read all of the written material and follow all of the precautions and directions before beginning an  

installation. All existing local and state plumbing codes must be followed. 

• 

Operation Pressure Range: 20 to 100 psi (140 to 690 kPa)

• 

Operating Temperature Range: 40° to 100° F (4° to 38° C)

• 

For cold water supply line installation only

• 

Do not locate unit in direct sunlight. Protect the unit from freezing.

• 

Chemical solvents should not be used to clean the unit. Only warm water with mild soap may be used, rinsing 

afterwards with clean water.

• 

Threads should be sealed using only Teflon

®

 tape. 

Do not use thread sealing compounds or paste.

• 

Using a torch near plastic housings can cause damage to the filter. Sweat joints must be made before attach

-

ing to the filter head. 

• 

If the water piping is used as an electrical ground, then a jumper wire must be installed around the filter.

• 

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection 

before or after the unit. Units certified for cyst reduction may be used on disinfected waters that may contain 

filterable cysts.

 

Warning:

 You must consult a water quality professional to test your water and recommend any necessary 

treatment for bacteria, chemicals, or other possible contaminants not removed by this filter. This cartridge will 

lose its effectiveness over time and must be changed in accordance with the printed instructions.