background image

Part #: 9015-896 (11/13)

THIS IS THE SAFETY ALERT SYMBOL.  IT IS USED TO ALERT 

YOU  TO  POTENTIAL  PERSONAL  INJURY  AND  OTHER 

HAZARDS. OBEY ALL SAFETY MESSAGES THAT FOLLOW 

THIS  SYMBOL  TO  REDUCE  THE  RISK  OF  PERSONAL 

INJURY AS WELL AS PROPERTY DAMAGE.

READ  CAREFULLY  THE  PRODUCT  INSTALLATION, 

OPERATING AND MAINTENANCE MANUAL. FAILURE 

TO  FOLLOW  THE  INSTRUCTIONS  AND  WARNINGS  IN  THE  MANUAL 

MAY  RESULT  IN  SERIOUS  OR  FATAL  INJURY  AND/OR  PROPERTY 

DAMAGE, AND WILL VOID THE PRODUCT WARRANTY. FOLLOW ALL 

APPLICABLE  LOCAL  AND  STATE  CODES  AND  REGULATIONS,  IN  THE 

ABSENCE OF SUCH CODES, FOLLOW THE CURRENT EDITIONS OF THE 

NATIONAL  PLUMBING  CODE  AND  NATIONAL  ELECTRIC  CODE,  

AS APPLICABLE.

This  Product,  like  most  Products  under  pressure,  may 

over  time  corrode,  weaken  and  burst  or  explode, 

causing serious or fatal injury, leaking or flooding and/or property damage. 

To minimize risk, periodically inspect the Product. A drip pan connected to 

an  adequate  drain  must  be  installed  if  leaking  or  flooding  could  cause 

property  damage.  Do  not  locate  in  an  area  where  leaking  could  cause 

property damage to the area adjacent to the appliance or to lower floors of 

the structure.

RUPTURE OR EXPLOSION HAZARD 

A relief valve must 

be installed to prevent pressure in excess of local code 

requirement  or  maximum  working  pressure  designated  in  the  Product 

Manual, whichever is less. Do not expose Product to freezing temperatures 

or  temperatures  in  excess  of  200°  F.  Do  not  adjust  the  pre-charge  or 

re-pressure this Product except for any adjustments required at the time of 

initial  installation,  especially  if  Product  is  corroded,  damaged  or  with 

diminished integrity. Adjustments to pre-charge must be done at ambient 

temperature  only.  Failure  to  properly  size  the  Product  or  follow  these 

instructions may result in excessive strain on the system lead to Product 

failure, serious or fatal personal injury, leakage and/or property damage.

Chlorine  &  Aggressive  Water: 

The  water  quality  can 

significantly  influence  the  life  of  this  Product.    You 

should test for corrosive elements, acidity, total solids and other relevant 

contaminants,  including  chlorine  and  treat  your  water  appropriately  to 

insure satisfactory performance and prevent premature failure.

Note:  

Inspect for shipping damage and notify freight carrier or store where 

purchased immediately if damage present. To avoid risk of personal injury 

and  property  damage,  if  the  product  appears  to  be  malfunctioning  or 

shows signs of corrosion, call a qualified professional immediately. Current 

copies of the Product manual can be viewed at www.waterworkerdiy.com. 

Use proper safety equipment when installing.

Use only with potable water system. Do not operate in 

a  setting  with  freezing  temperatures  or  where  the 

temperature can exceed 200° F and do not exceed the maximum working 

pressure specified for this Product.

EXPLOSION  OR  RUPTURE  HAZARD!  A  relief  valve 

must be installed to prevent pressure in excess of local 

code  requirement  or  maximum  working  pressure  designated  in  the 

Product  Manual,  whichever  is  less.  At  least  once  every  3  years  or  if 

discharge  is  present,  inspect  the  temperature  and  pressure  relief  valve 

and  replace  if  corrosion  is  evident  or  the  valve  does  not  function. 

FAILURE  TO  INSPECT  THIS  VALVE  AS  DIRECTED  COULD  RESULT  IN 

UNSAFE TEMPERATURE OR PRESSURE BUILD-UP WHICH CAN RESULT 

IN PRODUCT FAILURE, SERIOUS INJURY OR DEATH AND/OR SEVERE 

PROPERTY DAMAGE AND VOID THE PRODUCT WARRANTY.

FAILURE  TO  PROPERLY  SEAL  VALVE  CAP  WILL 

RESULT IN LOSS OF PRECHARGE CAUSING PRODUCT 

TO FAIL.

PRE-INSTALLATION

1.  Remove  valve  cap  and  adjust  air  charge  to  match  cold  water  supply 

pressure. Replace cap tightly to prevent air loss.

2.  Identify an installation point on the cold water line between the water 

heater and backflow preventor or other one-way device.

INSTALLATION
G5 and G12 with Saddle Valve (Use with Copper Pipe Only)

1.  Shut the cold water supply off and relieve water pressure.
2.  Assemble  the  saddle  valve  to  the  piping  as  shown.  Using  wrench 

provided, tighten the saddle valve to pierce the line and compress the 

gasket seal. Alternate screws while tightening.

3.  Install the tank using pipe sealing tape or paste.
4. Open the cold water supply and check for leaks.

MAINTENANCE

The installation should be inspected annually and more often as the system 

ages.  Check  for  signs  of  corrosion  and  indicators  of  excessive  water 

pressure levels, if any are present the unit should be replaced.

G5L and G12L Direct Connection

1.  Shut the cold water supply off and relieve water pressure.
2.  Install a pipe tee with a 3/4" NPTF threaded connection.
3.  Thread the tank into the tee using pipe sealing tape or paste.
4. Open the cold water supply and check for leaks.

See reverse side for warranty information.

INSTALLATION MANUAL FOR WATER HEATER EXPANSION TANK

Please read the following instructions carefully.

Keep this manual with the tank for future reference.

TANK

WRENCH
SCREWS

PIPE

GASKET

PIN

FITTING

Cold Water

Supply

One-Way

Device

Water Heater

Expansion Tank

Water

Heater

Hot Water

G5 & G12

TANK

THREADED TEE

(NOT INCLUDED)

Cold Water

Supply

One-Way

Device

Water Heater

Expansion Tank

Water

Heater

Hot Water

G5L & G12L