background image

CareSoft Pro Series

®

Metered Water Softeners

For Models:

• CSP-844
• CSP-948
• CSP-1044
• CSP-1054
• CSP-1248
• CSP-1354

For Cabinet Models:

• CSPC-835
• CSPC-935
• CSPC-1035

Summary of Contents for CSP-1044

Page 1: ...CareSoft Pro Series Metered Water Softeners For Models CSP 844 CSP 948 CSP 1044 CSP 1054 CSP 1248 CSP 1354 For Cabinet Models CSPC 835 CSPC 935 CSPC 1035...

Page 2: ...come when installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any qu...

Page 3: ...ickly exit any Programming Installer Settings etc press CLOCK Any changes made prior to the exit are incorporated If desired two regenerations within 24 hours are possible with a return to the preset...

Page 4: ...to the building while not allowing water to exit from the system to the building Fig 3 This allows the service technician to draw brine and perform other tests without the test water going to the buil...

Page 5: ...to be unscrewed or tightened by hand or with the special plastic Service Wrench CV3193 01 If necessary pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do...

Page 6: ...lamp or jumper wiring NOTE If replacing an existing softener also replace the ground clamps wire If removing a softener replace the piping with the same type of piping as the original to assure plumbi...

Page 7: ...ilding structure Your softener is equipped with a brine tank safety float which greatly reduces the chance of an accidental brine overflow In the event of a malfunction however an overflow line connec...

Page 8: ...S Set the amount of hardness in grains per gallon default 20 using the or buttons The allowable range is from 1 to 150 in 1 grain increments Note Increase the grains per gallon if soluble iron is pres...

Page 9: ...displays One of the displays is always the current time of day The second display shows the current treated water flow rate through the system in Gallons Per Minute The third display is one of the fo...

Page 10: ...thereafter see Start Up Instructions for regeneration sequence the water softener will deliver water but it will be untreated IMPORTANT With the Dry Salt Storage Feature the brine tank will refill 4 h...

Page 11: ...er softener include a dry salt storage feature no water in brine tank between regeneration the manufacturer recommends the use of solar salt for best results The brine tank is manufactured for the use...

Page 12: ...up it could result in a salty water complaint after the first regeneration During the first regeneration the unit will draw out the initial volume of brine regenerant and refill it with the correct pr...

Page 13: ...any remaining debris and air from the system again 1 Full open a cold water faucet preferably at a laundry sink or bathtub without an aerator 2 Wait two to three minutes or until water runs clear then...

Page 14: ...remove meter and check for debris D defective meter D replace meter E defective PC board E replace PC board Unit regenerates at wrong time of day A past power outage A reset time of day B incorrect t...

Page 15: ...circuit board failure _______________ TWIN ALT SYSTEMS Error code 1006 motor ran too long Error code 1007 unexpected stall A valve has just been serviced 1001 A press NEXT and REGEN for 5 seconds or...

Page 16: ...837 01 CareSoft Pro cover 1 2 CV3107 1 Motor 1 3 CV3106 1 Drive bracket spring clip 1 4 CV3851WN PC board 1 5 CV3110 Drive gear 12 x 36 3 6 CV3109 Drive gear cover 1 7 CV3002CC Drive assembly CV3186 T...

Page 17: ...ston assembly upflow 1 CV3407 1 25 piston assembly downflow 1 5 CV3174 Regenerant piston 1 6 CV3180 O ring 337 1 7 CV3105 O ring 215 1 8 CV3556 Screw 1 4 20x1 1 2 18 8SS 1 9 CCI 00318337 Nut 1 4 20 HE...

Page 18: ...on Qty 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3145 Bypass rotor 1 2 5 CV3146 Bypass cap 2 6 CV3147 Bypass handle 2 7 CV3148 Bypass rotor seal retainer 2 8 CV315...

Page 19: ...BLUE CV3010 1G G injector assembly YELLOW CV3010 1H H injector assembly GREEN CV3010 1I I injector assembly ORANGE CV3010 1J J injector assembly LIGHT BLUE CV3010 1K K injector assembly LIGHT GREEN n...

Page 20: ...1 0 DLFC for 3 4 elbow CV3162 013 1 3 DLFC for 3 4 elbow CV3162 017 1 7 DLFC for 3 4 elbow CV3162 022 2 2 DLFC for 3 4 elbow CV3162 027 2 7 DLFC for 3 4 elbow CV3162 032 3 2 DLFC for 3 4 elbow CV3162...

Page 21: ...8 01 Turbine assembly 1 4 CV3105 O ring 215 1 5 CV3003 01 Meter plug assembly 1 6 CV3013 Optional mixing valve 1 REPLACEMENT PARTS Although no tools are necessary to assemble or disassemble the valve...

Page 22: ...grid support 6 needed WC 1 CH1088 Optional Salt grid handle WC 1 CH1072 01 Optional 18 diameter salt grid 1 CH1080 Optional 24 diameter salt grid 1 3 CG21833CB1C00 18 x 33 brine tank black 1 CG21840C...

Page 23: ...ion Qty 1 CG2197 01 Salt and tank cover must be ordered together 1 2 CG2724HP 01 Windsor cabinet white with black lids 1 3 CH1090 01 Optional salt grid for 8 diameter tank and 4 brine well 1 CH1090 02...

Page 24: ...1 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assemb...

Page 25: ...3375 Fitting 2 3 4 JOHN GUEST ELBOW Item No Part No Description Qty CV3007 15 3 4 John Guest elbow assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3790 Fittin...

Page 26: ...ax Service PSI 8 6 14 1 15 0 Min to Max Working Pressure PSI 30 100 30 100 30 100 Min to Max Operating Temperature F 33 100 33 100 33 100 Max Flow to Drain During Regeneration GPM 1 3 1 7 2 2 Amount o...

Page 27: ...ponent at its expense and return part freight collect The above provisions of the warranty are valid as long as the unit is connected in compliance with local plumbing codes and in an equivalent manne...

Page 28: ...steps as shown to the right Access this mode by pressing NEXT and button simultaneously NOTE Hardness display shows nA if used as a filter If other displays do not appear refer to manual QUICK REFERE...