background image

WL Max Technical Manual - Version 1 - May 2013

WL Max 

Technical Manual

Summary of Contents for WL Max

Page 1: ...WL Max Technical Manual Version 1 May 2013 WL Max Technical Manual...

Page 2: ...ures PDI 11 Installation Procedures 12 Installation Kit 14 Operating Instructions 15 Maintenance and Servicing 16 Sanitizing 18 Fault Finding 20 Technical Specifications and Warranties 22 End of Life...

Page 3: ...ne and pesticides It is important for the UV sterilization system to be supplied with clean water in order to achieve maximum efficiency There are many kinds of different filter combinations available...

Page 4: ...all the mechanical and electrical parts 24V DC including the solenoid valves COMPRESSOR The compressor operates at 220 240V at 50Hz or 120V at 60Hz It uses 165g of R134a non Ozone depleting refrigera...

Page 5: ...et Flow Diagram Double Faucet DRAIN VALVE FILTER IN Water COLD WATER OUT FILTER DRYER ICE BANK COMPRESSOR CONDENSER COLD SENSOR SOLENOID VALVE DRAIN VALVE FILTER IN Water COLD WATER OUT FILTER DRYER I...

Page 6: ...top cover from the Firewall Housing and inspect the quartz spiral for damage If all is ok then re assemble 7 Connect to a potable drinking water supply via a 1 4 John Guest tube the sup ply must be li...

Page 7: ...away from the top 8 Replace the cap on the top of the reservoir 9 Make the water connection using an installation kit Waterlogic recommends the use of a pressure reducing valve a shut off valve and a...

Page 8: ...water 3 Adjustable Pressure Reducing Valve 4 Integral Isolator 5 Pressure Gauge Port 6 Waterblock 7 1 4 Pushfit Outlet The part number for the installation kit shown below is P KIT INSTALLATION Your...

Page 9: ...directly into the inlet side of the filter and attach another length of pipe to the outlet side and direct this into a bucket large container or drain then allow 10 litres of water to pass through the...

Page 10: ...itisation fluid leaves the faucet Whilst you are dispensing the cold water hold a peroxide test strip under the dispense area and test the flow of water to check that the sanitisation fluid is present...

Page 11: ...sconnect power supply for one hour to allow the tank to defrost and then flush the cold water system Check the temperature settings are correct If the cold reservoir is not frozen then check the solen...

Page 12: ...erlogic has a policy of constant and continual improvement and therefore reserves the right to change specifications without prior notice other than in the case of significant changes Description WL M...

Page 13: ...r technology is manufactured into the surface of our products giving them built in sustainable antimicrobial protection BioCote s silver technology has been tested by an independent laboratory to show...

Page 14: ...26 27 WL Max Technical Manual Version 1 May 2013 Electrical Wiring Diagram 230V DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING...

Page 15: ...No Part Description 1 PU 4031 JG 1 4 PE Pipe 2 PU 4028 JG Bulkhead Connector Union 1 4 1 4 3 PU 4031 JG 1 4 PE Pipe 4 FT 0034 10 Inline CBC Filter 1 Micron 5 PU 4008 JG Equal Elbow Connector 1 4 6 St...

Page 16: ...rt Description 1 PU 4031 JG 1 4 PE Pipe 2 PU 4028 JG Bulkhead Connector Union 1 4 1 4 3 PU 4031 JG 1 4 PE Pipe 4 FT 0034 10 Inline CBC Filter 1 Micron 5 PU 4008 JG Equal Elbow Connector 1 4 6 Stainles...

Page 17: ...1 4 Elbow 13 Quartz Spiral 14 JG 1 4 Straight Connector 15 Firewall Housing 16 Solenoid Valve 24V DC 17 Back Cover 18 JG 1 4 Straight Connector 19 JG 1 4 Divider 20 Ballast 15W 220 V 21 Firewall displ...

Page 18: ...0 Inline CBC Filter 31 JG 1 4 Bulkhead Connector 32 Filter Clip 33 JG 1 4 Elbow 34 JG 1 4 Straight Connector 35 Drain Hose 36 Reservoir Tank Lid 37 Pump 38 Reservoir 39 Thermostat 40 Drain Connection...

Page 19: ...Beacon Court Sandyford Dublin 18 Ireland www waterlogic com Waterlogic USA 4141 N 156th Street Omaha NE 68116 Speak to a Water Expert Rest of the world exportsales waterlogic com 353 1 293 1960 USA Ca...

Reviews: