background image

 

WL200 Manual 

                                                                    Page 39 - Revision: 4-29-2019 

POWER TROUBLESHOOTING INDEX 

 

  

1.  Red Power Switch is lit but the red LED on the Front is not lit 

 

2.  Compressor Runs but does Not Chill 

 

3.  Compressor is Not Running  

 

 

1.

 

Red Power Switch is lit but the Red LED on the Front is not lit  

 

 

Possible Reason 

Solution 

Bad Transformer 

Replace Transformer 

Black Power Connector to the 

PCB is not properly connected  Properly connect. 

Bad Front PCB  

Replace Main PCB  

Part Number:  EN-6086 / Waterlogic P/N 12-8615.  

Defective Red Power / 

Compressor Switch 

Replace Red Power / Compressor Switch 

 

2.

 

Compressor Runs But Does Not Chill 

 

 

Possible Reason 

Solution 

Condenser is dirty 

Clean the condensing coil of any obstructions or dust. 

Reduction of airflow into unit.  Make sure unit is not under minimum ventilation requirements (2 

to 4 inches). 

Compressor is running very 

hot. 

Low or lost refrigerant.  Refrigerant recharge required. 

 

 

 

Reviews: