HOT WATER TROUBLESHOOTING INDEX 

 

Hot Water Problems 

 

  

1.  Hot Water is not Hot 83°C (181° +/- 5°F) 

  

Also includes related instructions for Resetting the Hot Tank Overload or High Limit 
Safety 

 

1.

 

Hot Water is not Hot 83°C (181° +/‐ 5°F) 

 

NOTE:  

The 

WL270

 

Water Treatment System

 does NOT have Sleep or Power Saving Mode and the 

hot water should be a minimum of 181°F under normal operating conditions. 

 

The Hot temperature set point is 181

°

 F and is controlled by a thermostat on the side of the tank. 

 

There is a resettable overload or high limit safety above the thermostat on the side of the tank that 
will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it). 

 

The 

WL270

 

Water Treatment System

 does NOT have Extra Hot capability and the maximum hot 

temperature is 186°F. 

 

It typically takes 10 minutes for the 600W Hot Tank to heat the 1.6 Liter of room temperature 
(ambient) water to the 83°C (181°F) set point.

 

 

Possible Reason 

Solution 

No power to heater elements 

Check that the Red Heater and Compressor 
switch is on. 
 
Turn Red Heater and Compressor Switch on.   

I = ON

 

Hot Tank Overload Devices 
(High Safety Limit) tripped   
 

Hot Tank Overload Devices 
(High Safety Limit) is a safety 
feature to ensure the tank 
does not overheat. 

Hot Tank Overload Devices (High Safety Limit) will “click” 
when pushed.  The Hot Tank Overload Devices (High Safety 
Limit) are automatically reset when pressed.   
 

See Resetting

 

Hot Tank Overload Devices (High Safety Limit) 

Instructions that are included further below in this 
Troubleshooting Section

 

Hot Tank Overload Devices 
(High Safety Limit) “open” on 
Hot Tank 

Turn Power off.   
 
Check OHM’s resistance across terminals on each of the Hot 
Tank Overload Devices (High Safety Limit) separately. Good 
components will indicate a closed circuit or zero OHM’s on 
the meter. 
Replace components as necessary. 