WL270
Manual
Page 51 – Revision 3‐4‐2019
HOT WATER TROUBLESHOOTING INDEX
Hot Water Problems
1. Hot Water is not Hot 83°C (181° +/- 5°F)
Also includes related instructions for Resetting the Hot Tank Overload or High Limit
Safety
1.
Hot Water is not Hot 83°C (181° +/‐ 5°F)
NOTE:
The
WL270
Water Treatment System
does NOT have Sleep or Power Saving Mode and the
hot water should be a minimum of 181°F under normal operating conditions.
The Hot temperature set point is 181
°
F and is controlled by a thermostat on the side of the tank.
There is a resettable overload or high limit safety above the thermostat on the side of the tank that
will trip to prevent damage to the unit if the tank is dry heated (turned on without water in it).
The
WL270
Water Treatment System
does NOT have Extra Hot capability and the maximum hot
temperature is 186°F.
It typically takes 10 minutes for the 600W Hot Tank to heat the 1.6 Liter of room temperature
(ambient) water to the 83°C (181°F) set point.
Possible Reason
Solution
No power to heater elements
Check that the Red Heater and Compressor
switch is on.
Turn Red Heater and Compressor Switch on.
I = ON
Hot Tank Overload Devices
(High Safety Limit) tripped
Hot Tank Overload Devices
(High Safety Limit) is a safety
feature to ensure the tank
does not overheat.
Hot Tank Overload Devices (High Safety Limit) will “click”
when pushed. The Hot Tank Overload Devices (High Safety
Limit) are automatically reset when pressed.
See Resetting
Hot Tank Overload Devices (High Safety Limit)
Instructions that are included further below in this
Troubleshooting Section
Hot Tank Overload Devices
(High Safety Limit) “open” on
Hot Tank
Turn Power off.
Check OHM’s resistance across terminals on each of the Hot
Tank Overload Devices (High Safety Limit) separately. Good
components will indicate a closed circuit or zero OHM’s on
the meter.
Replace components as necessary.