Page 13 – Revision: 1-21-2021
SERVICE REQUIREMENTS
WARNING!
Read and understand the contents of this manual before attempting to
service WL900 Water Treatment System. Failure to follow the instructions in this
manual could result in death, serious personal injury, or severe property damage.
Only trained and qualified technicians should attempt to install, maintain, or service
Waterlogic Equipment.
1.
Visually inspect all electrical and water connections for signs of wear or damage.
2.
Ensure there is adequate (minimum of 2”) clearance around the
WL900
Water and Ice
Machine
and clean the condenser grill and compressor fan to provide efficient cooling
system operation.
3.
Sanitize the cold tank, ambient tank, and ice-making area per instructions in the pre-
installation procedures.
WARNING!
SANITIZER MAY CONTAIN HAZARDOUS CHEMICALS.
Use of proper
personal protective equipment such as rubber gloves and eye protection are required.
4.
Clean and sanitize external surfaces of the
WL900
Water and Ice Machine.
Use soap and
water or chemicals that are compatible with ABS plastic and will not damage or degrade the
product surfaces.
5.
Remove and clean the Faucet on every service visit.
6.
Change out filters every 6 months, or as needed.