background image

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CPK-5 Fire Pumps 

  

Installation Instructions 

 

 
 

Table of Contents 

 

Safety Information ...................................................... 2 

Introduction ................................................................. 3 

General Description .................................................... 3

 

Pump Mounting  - General Information ..................... 3

 

Pump Mounting ........................................................ 4-9

 

Pump and Transmission ......................................... 4-7 

Oil Pump and Cooler .............................................. 8-9 

Final Checks .............................................................. 10

 

Lubrication ............................................................... 10 

Testing .................................................................... 10 

 
 
 
 
 
 
 
 
 
 
 

Read through the installation in- 
structions carefully before installing 
your Waterous CPK-5 Series Fire 
Pump.

 

 
 
 

 

NOTE: Instructions subject to change without notice 

 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 

F-1031, Section 3046 (Revised: 12/7/18) 

 

Waterous Company, 125 Hardman Avenue South, South St. Paul, Minnesota  55075  USA  (651) 450-5000 

www.waterousco.com

 

 

Summary of Contents for CPK-5 Series

Page 1: ...ansmission 4 7 Oil Pump and Cooler 8 9 Final Checks 10 Lubrication 10 Testing 10 Read through the installation in structions carefully before installing your Waterous CPK 5 Series Fire Pump NOTE Instr...

Page 2: ...to connection or removal of hoses caps or other closures with pump intake or pump discharge connec tions relieve pressure by opening drains or bleeder valves Bleeder valves should also be used while...

Page 3: ...ere propeller shaft flanges are parallel and yokes are aligned Refer to this table when positioning a pump to deter mine proper shaft angles Be sure to keep at least a minimum of 1 U joint operating a...

Page 4: ...ared to the driveshaft rota tion see dimensional drawings for correct rotation configurations Position the pump transmission within the vehicle frame rails and secure the brackets not supplied to the...

Page 5: ...F 1031 Section 3046 Page 5 of 10 Figure 2 Pump Dimensions Inverted Transmission Pump Mounting CPK 5 Series con t...

Page 6: ...F 1031 Section 3046 Page 6 of 10 Pump Mounting CPK 5 Series con t Figure 3 Pump Dimensions Horizontal Transmission...

Page 7: ...F 1031 Section 3046 Page 7 of 10 Pump Mounting CPK 5 Series con t Figure 3 Pump Dimensions Vertical Transmission...

Page 8: ...ns and connection points for the oil pump and cooler that is used on the CPK 5 NOTE Before installation make sure your pump has the right rotation as compared to the driveshaft rota tion see dimension...

Page 9: ...Figure 5 Oil Pump and Cooler Mounting Diagram Continued F 1031 Section 3046 Page 9 of 10...

Page 10: ...stalled fill transmission with 1 5 quarts of gear lube 2 Run electric oil pump for 1 minute 3 Stop oil pump 4 Remove oil level plug 5 Drain excess oil or add oil until a small stream of oil runs out o...

Reviews: