background image

Available F4T/D4T Literature and Resources

Document Title and Part 

Number

Description

F4T Installation and Trou-

bleshooting User Guide, 

part number: 

0600-0092-

0000

Provides detailed specifications  and infor-

mation regarding mounting the base, flex 

module wiring and troubleshooting. 

F4T Setup and Operations 

User Guide, part number:

0600-0093-0000

Explains how to configure and operate the 

device for an application using Composer 

software as well as the user interface 

(touch screen).  Includes detailed descrip-

tions of all device features and parameter 

settings.

D4T Installation and Trou-

bleshooting User Guide, 

part number: 

0600-0107-

0000

Provides detailed specifications  and infor-

mation regarding mounting the base, flex 

module wiring and troubleshooting. 

D4T Setup and Operations 

User Guide, part number:

0600-106-0000

Explains how to configure the datalogger 

for an application using the user interface 

and Composer software. Includes detailed 

descriptions of all data logger features 

and parameter settings.

Installation and Wiring 

To install the flex module:

1.

Note the part number to determine the number and type of inputs or

outputs available to be connected in step 7.

2.

Turn off device power.

3.

Select a compatible base slot for the module. See the Flex Module-Slot

Dependencies table below. If replacing a module, remove the old

module.

4.

Affix corresponding slot number labels (provided) to the module and to

the removable screw terminal block.

0600-0096-0000 Rev. D

 

Made in the U.S.A.

November 2016

1 2

3 4

F4T/D4T Flex Module

Quick Start Guide

Registered Company

 Winona, Minnesota  USA 

ISO 9001

TOTAL

3 Year Warranty

CUSTOMER

SATISFACTION

High Density Input/Output Modules

FM

HA

-_ _ _ _-_ _ _ _

Safety Information

We use caution symbols where needed within this document to draw your at-

tention to important operational and safety information.

A “CAUTION” safety alert appears with information that is important for pro-

tecting your equipment and performance. Be especially careful to read and 

follow all cautions that apply to your application.

A “WARNING” safety alert appears with information that is important for 

protecting you, others and equipment from damage. Pay very close attention 

to all warnings that apply to your application.

The electrical hazard symbol, (a lightning bolt in a triangle) precedes an 

electric shock hazard CAUTION or WARNING safety statement. Further expla-

nations follow:

Symbol

Explanation

ç

Ó

CAUTION – Warning or Hazard that needs fur-

ther explanation than label on unit can provide.  

Consult QSG for further information.

AVERTISSEMENT: mise en garde ou danger qui 

demande plus de précisions que l’information sur 

l’étiquette de l’unité. Consultez le manuel de l’uti-

lisateur pour plus d’informations.

Document Overview

The purpose of this Quick Start Guide (QSG) is to acquaint the user with the 

F4T/D4T High Density (HD) Flex Modules and associated wiring. 

Product Overview

Flex modules serve as the interface between real-world devices and the F4T/

D4T system. The flex modules described in this document offer various input 

and output options and greater density (more than 1) than the standard flex 

modules. With the exception of the Dual SSR module, all of these modules can 

be placed in any available slot.   

CAUTION 

WARNING

Electrical 

Shock 

Hazard

5.

With the component side of the module facing right (viewing the F4T/D4T

from the rear) insert the module into the slot until it latches.

6.

Remove the screw terminal block from the module.

7.

Wire field devices to the appropriate terminals. Wiring details for each in-

put and output are provided in the following sections.

8.

Reconnect the wired screw terminal block to the module. Be sure to

recon-nect the terminal block to the correct module.

9. Restore power to the F4T/D4T.

Note:

If the flex module is a replacement with 

the same part number and slot position, 

the F4T/D4T uses it immediately when 

powered up. Otherwise, use Composer 

software to configure the F4T/D4T to 

ex-pect and use the module. 

Module Characteristics

Description and Identification

Many of the modules appear to look alike at first glance, therefore, it is 

always recommended that the module part num-

ber be verified prior to plugging it into any of the 

available slots in a base. Each module is identified 

with a part number located on the back side of the 

assembly next to the screw terminal block, as dis-

played in the graphic to the right.

Wiring

Prior to wiring any of the I/O modules described in this document, it is 

rec-ommended that the warnings and notes listed below be reviewed.

CAUTION: 

ç

To prevent damage to the F4T/D4T, do not connect wires to unused termi-

nals.

All Other Modules

Communications

FMCA-(2)

Dual SSR 

*

FMHA-K

Flex Module - Slot Dependencies

4

5

6

1

2

3

Y

N

Y

Y

N

Y

Y

Y

Y

Y

Y

Y

N

N

N

N

N

Y

N = Not allowed 

Y = Allowed

Slot #

Module Type

*

 Reguires two adjacent slots

F M

 H A - _ _ _ A - A _ _ _

or

www.calcert.com

sales@calcert.com

1.888.610.7664

0

5

10

15

20

25

30

Reviews: