background image

Installation Instructions:  

The 2300 Direct Operated Reducing Valve is designed for dead-

end water service where the flow is intermittent and changes 

rapidly, as on domestic water systems.  It is especially effective 

in regulating the flow of water to such fast acting equipment as 

flushometers and snap cocks. The design is self contained, no 

control pipe is required.
The preferred position for the 2300 is in a horizontal line with the 

spring chamber up.  When so mounted, the tendency of sedi-

ment to settle in the control ports is practically eliminated.

 

RATINGS 

(Maximum Inlet Conditions)

 

Valve Ends 

Pressure Bar 

(Temperature)

 

 ANSI 250 Flanged  

200 psig 13.8 

(200°F) 93°C

SPRING RANGES

 30 to 80 psig (207-552 kPa)

Series 2300

Water Pressure Reducing Valve

Sizes:  3"– 4" (80-100mm)

IS-2300

Series 2300

 

Valve Size

 

3 4

 C

v

 

32 52

  

 

 

FACE TO FACE 

  OTHER DIMENSIONS 

 

APPROX. WEIGHT

  

 

 

E

 

SIZE 

  ANSI ANSI ANSI  A 

C  ANSI ANSI ANSI

 

IN. 

MM 

NPT 125  250   

 

  NPT 125  250

 3 

80 

— 

10 

10

3

4

 6 21

3

4

  9  — 108 128

 4  100 

— 

11

7

8

 12

1

2

 6

5

8

 26

5

8

 11

1

4

 

  

198 

225

RATED FLOW COEFFICIENTS (Cv)

DIMENSIONS (inches) AND WEIGHTS (pounds)

ENGLISH INSTRUCTIONS

Local building or plumbing codes may require modifica-

tions to the information provided.  You are required to  

consult the local building and plumbing codes prior 

to installation.  If the information provided here is not 

consistent with local building or plumbing codes, the 

local codes should be followed.  This product must be 

installed by a licensed contractor in accordance with 

local codes and ordinances.

WARNING

!

Need for Periodic Inspection/Maintenance:

  This product 

must be tested periodically in compliance with local codes, 

but at least once per year or more as service conditions 

warrant.  All products must be retested once maintenance 

has been performed.  Corrosive water conditions and/or 

unauthorized adjustments or repair could render the product 

ineffective for the service intended.  Regular checking and 

cleaning of the product’s internal components helps assure 

maximum life and proper product function. 

WARNING

!

WARNING

!

Read this Manual BEFORE using this equipment.
Failure to read and follow all safety and use information 

can result in death, serious personal injury, property 

damage, or damage to the equipment.
Keep this Manual for future reference.

Summary of Contents for 2300 Series

Page 1: ...ENTS Cv DIMENSIONS inches AND WEIGHTS pounds ENGLISH INSTRUCTIONS Local building or plumbing codes may require modifica tions to the information provided You are required to consult the local building...

Page 2: ...ooting Inadequate flow or delivery pressure 1 Check initial pressure to see if full intended line pressure is applied at the valve inlet Reduced pressure builds up 1 Foreign matter may be lodged betwe...

Page 3: ...te 2 Stainless Steel 12 Diaphragm Nut Steel 13 Dowel Pin Note 2 Steel 14 Stem Note 2 Stainless Steel 15 Body ANSI NPT Scr Cast Iron Body ANSI 125 Fig Cast Iron Body ANSI 250 Cast Iron 16 Sealing Ring...

Page 4: ...SS OR IMPLIED THE COMPANY HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURP...

Page 5: ...108 lb 58 kg 128 lb 4 100 301 mm 117 8 pulg 318 mm 121 2 pulg 168 mm 65 8 pulg 672 mm 265 8 pulg 286 mm 111 4 pulg 90 kg 198 lb 102 kg 225 lb ADVERTENCIA Los c digos locales de construcci n o fontaner...

Page 6: ...a indicada en la entrada de la v lvula Se acumula presi n reducida 1 Puede haber materia extra a entre el disco 20 y el anillo de asiento 19 Quite la brida ciega 24 e inspeccione 2 Puede estar roto e...

Page 7: ...si n Nota 2 Hierro fundido 8 Diafragma Nota 1 2 Hycar 9 Pernos del diafragma Acero 10 Base Hierro fundido 11 Acoplamiento del v stago Nota 2 Acero inoxidable 12 Tuerca del diafragma Acero 13 Pasador g...

Page 8: ...TALES APLICABLES LAS GARANT AS IMPL CITAS QUE NO PUEDAN DESCONOCERSE INCLUIDAS LAS GARANT AS IMPL CITAS DE COMERCIALIZACI N O APTITUD PARA UN FIN ESPEC FICO EST N LIMITADAS EN SU DURACI N A UN A O DES...

Page 9: ...m 265 8 po 286 mm 111 4 po 90 kg 198 lb 102 kg 225 lb Les codes locaux du b timent ou de la plomberie peuvent n cessiter des modifications aux renseignements donn s Vous tes tenus de consulter des cod...

Page 10: ...au niveau du robinet d admission Accumulation de r duction de pression 1 Des corps trangers peuvent tre log s entre le disque 20 et la bague de si ge du corps 19 Enlever la bride pleine 24 pour inspe...

Page 11: ...pression Remarque 2 Fonte 8 Membrane Remarque 1 et 2 Hycar 9 Boulons de membrane Acier 10 Base Fonte 11 Raccord de tige Remarque 2 Acier inoxydable 12 crou de membrane Acier 13 Goupille Remarque 2 Aci...

Page 12: ...FRE AUCUNE AUTRE GARANTIE EXPRESSE OU TACITE PAR LA PR SENTE LA SOCI T REJETTE SP CIFIQUEMENT TOUTE AUTRE GARANTIE EXPRESSE OU TACITE NOTAMMENT TOUTE GARANTIE TACITE DE QUALIT MARCHANDE OU D ADAPTATIO...

Reviews: