 The Wayne pumps are general use 
centrifugal water pumps. The pump is 
equipped with a Viton

®

 seal assembly 

that is also compatible with many 
agricultural chemicals.

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols.

  

Danger 

 indicates 

an imminently hazardous situation which, 
if not avoided, WILL result in death or 
serious injury.

  

Warning 

 indicates 

a potentially hazardous situation which, 
if not avoided, COULD result in death or 
serious injury.

  

Caution 

 indicates 

potentially minor or moderate injury.

  

Notic

 indicates 

important information, that if not 
followed, may cause damage to 
equipment.

General Safety 
Information

 CALIFORNIA PROPOSITION 65

  

This 

 product 

or its power cord may contain chemicals 
known to the State of California to 
cause cancer and birth defects or other 
reproductive harm. Wash hands after 
handling.

1.   Know the pump application, 

limitations, and potential hazards. 
Read these rules and the instructions 
carefully. Failure to follow them could 
cause serious bodily injury and/or 
property damage.

 

Never run engine in an 
enclosed area. Exhaust gases 
contain deadly poisonous 
carbon monoxide, which has 
no odor or taste.

 

 

 

 

Do not use to pump flammable 
or  explosive fluids such as 
gasoline, fuel oil, kerosene, etc.  
Do not use in flammable and/or 
explosive atmospheres. Pump should only 
be used with liquids compatible with pump 
component materials. Failure to follow 
this warning can result in personal injury 
and/or property damage.

2.  Observe all safety precautions for the 

handling of the fuel.

 

 

 

 

Do not refuel a hot engine. Fuel 
spilled on a hot engine could 
result in a fire or explosion. Do 
not refuel a running engine.

3.  Pump should be located and should 

rest on a level solid foundation. Do 
not suspend pump by means of the 
discharge pipe.

  

Be 

sure

  pump is on 

secure footing so it doesn’t fall over.

4.  Do not use torches or apply excessive 

heat, fire or flames to this pump as an 
explosion may result.

5.  Before working on the unit, insulate 

the wire from the spark plug, by 
disconnecting the spark plug wire from 
the spark plug.

  

Complete

   pump and 

piping system MUST be protected against 
below freezing temperature. Failure to do 
so could cause serious damage and voids 
the warranty.

6. 

Do not run pump dry. Water is 
required to lubricate the shaft seal.

7.  Pumping chemicals or corrosive liquids 

with this pump may shorten the life of 
the pump and may be hazardous to the 
operator.

8. Personal 

Safety:

a. Wear safety glasses at all times when 

working with pumps.

b. Keep work area clean, uncluttered 

and properly lighted; replace all 
unused tools and equipment.

c. Keep visitors at a safe distance from 

the work area.

d. Make workshop child-proof with 

padlocks, master switches, and by 
removing starter keys. 

9.  This pump is designed for non-abrasive 

fluid transfer; do not use as a trash 
pump. Always use a suction strainer 
with this pump to filter abrasive 
material. Abrasive materials such as 
sand and gravel will shorten the life of 
the pump.

 Operating Instructions and Replacement Parts List

GPS400

 See Warranty on page 8 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or fi le it for safekeeping.

 © 2007 Wayne Water Systems

320602-001 7/07

Q

UA

LIT

Y

A

SSURANCE

P

ROG

RA

M

Need

Assistance?

Call Us First!

1-800-237-0987

 For parts, product & service information

visit

 www.waynepumps.com

Summary of Contents for GPS400

Page 1: ...ds compatible with pump component materials Failure to follow this warning can result in personal injury and or property damage 2 Observe all safety precautions for the handling of the fuel Do not ref...

Page 2: ...Continue adding water until the water level is approximately 3 inches from the top Install the priming plug The water in the pump will create the suction that primes the pump 10 Turn fuel valve to ON...

Page 3: ...15 20 25 20 6600 6420 6180 6000 5640 5220 30 6180 6000 5640 5220 4800 4380 40 5640 5220 4800 4380 4080 3660 50 4800 4380 4080 3660 3300 2820 60 4080 3660 3300 2820 2400 1800 70 3300 2820 2400 1800 126...

Page 4: ...nder suction Hose coupled both ends with 2 hose thread One 20 ft hose per carton 2 SUCTION STRAINER PART 66036 Prevents stones leaves and other debris from clogging pump For Pump Accessories call 1 80...

Page 5: ...12701 5 11 Capscrew 5 16 24 x 7 8 16209 4 12 Lockwasher split 5 16 not shown 15916 4 13 Handle 56722 001 1 14 Base 11007 001 1 1 3a 11 5 10 2 3 6 4 13 8 7 14 For Replacement Parts call 1 800 237 0987...

Page 6: ...6 Notes Operating Instructions and Replacement Parts List www waynepumps com...

Page 7: ...7 GPS400 www waynepumps com Maintenance Service Record Date Maintenance Performed Replacement Components Required...

Page 8: ...implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations might not apply to you This limited warranty gives you specific leg...

Reviews: