background image

Utilice solamente repuestos de fábrica para reparar esta bomba

Manual de Instrucciones de Operación y Piezas

JSU50

Para Piezas de Repuestos, Llame al 1-800-237-0987

No. de

No.

Ref.

Descripción

Repuesto

Ctd.

1

Motor

32059-001

1

2

Tornillo

16636-002

4

3

Junta cuadrada de goma del anillo

17150-001

1

Ensamblaje de sellado del eje

56393

1

5

Impulsor

23285-002

1

6

Difusor

17148-001

1

7

Tornillo

17165-001

2

8

Anillo en O

15557

1

Envíe su solicitud de repuestos a la siguiente direccion:

Wayne Water Systems
100 Production Drive
Harrison, OH  45030   U.S.A.

9

Venturi

17151-002

1

10

Boquilla

15672

1

11

Δ

Tapón del tubo de 3/4"

15921

1

12

Caja de la bomba

41033-001

1

13

Base

23029-001

1

14

Presostato

30010-001

1

15

Plato decierre

4372-001

1

Δ

No se muestra

No. de

No.

Ref.

Descripción

Repuesto

Ctd.

Sírvase proporcionar la suguiente información:

- Número de modelo
- Número de serie (si tiene)
- Descripción y número de repuesto como se muestra

en la lista de repuestos

Garantía Limitada

Durante un año a partir de la fecha de compra, Wayne Water Systems ("Wayne") reparará o reemplazará, según lo consideren ade-
cuadon, cualquier pieza de esta bomba para sumideros (“Producto”) que el comprador original envie a reparación y los empleados o rep-
resentantes autorizados de Wayne determinen que están defectuosos debido a problemas de materiales o manufactura. Para recibir
información sobre los pasos a seguir, comuníquese directamente con la compañía Wayne (800-237-0987, sólo desde EE.UU.), o con el dis-
tribuidor autorizado más cercano a su domicilio. En el momento de reclamar sus derechos bajo esta garantía deberá suministrarnos el
número del modelo. Todos los gastos de flete serán la responsabilidad del comprador.
Esta garantía limitada no cubre los daños debido a accidentes, abusos, uso inadecuado, negligencia, instalación inadecuada, manten-
imiento inadecuado, o funcionamiento sin seguir las instrucciones suministradas por escrito por la compañía Wayne.

NO HAY NINGUNA OTRA GARANTIA EXPRESA O IMPLISITA. INCLUYENDO AQUELLAS SOBRE VENTA O USOS ESPECIFICOS, Y LAS
GARANTIAS ESTAN LIMITADAS A UN AÑO A PARTIR DE LA FECHA DE COMPRA. ESTA ES LA UNICA GARANTIA Y CUALQUIER
PERDIDA O RESPONSABILIDAD CIVIL, SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DAÑOS SON EXCLUIDAS.

Algunos estados no permiten límites en la duración de las garantías, o no permiten que se limiten o excluyan casos por daños por acci-
dentes o consecuentes, en dichos casos los límites arriba enumerados tal vez no apliquen para Ud. Esta garantía limitada le otorga a Ud.
ciertos derechos que pueden variar de un estado a otro.
Bajo ninguna circunstyancia, aunque sea debido al incumplimiento del contrato de garantía, culpabilidad (incluyendo negligencia) u
otras causas,la compañía Wayne o ninguno de sus surtidores serán responsables legalmente por ningún fallo legal en su contra, incluyen-
do, pero no limitado apérdida de ganancias, pérdidas del uso del producto o piezas asociadas con el equipo, pérdidas de capital, gastos
para reemplazar los productos dañados, pérdidas por cierre de fábrica, servicios o pérdida de electricidad, o demandas persentadas por
los clientes del comprador por dichos daños.
Ud. 

DEBE

conservar el recibo como prueba de compra junto con esta garantía. En caso de que necesite presentar un reclamo de sus dere-

chos bajo esta garantía, Ud 

DEBERA 

enviar una 

copia

del recibo de la tienda junto con el producto o correspondencia. Comuníquese

con la compañía Wayne (800-237-0987, sólo desde EE.UU) para recibir autorización e instrucciones de como enviar la mercancía.

NO ENVIE ESTOS DATOS A WAYNE. 

Conserve esto sólo como datos.

MODEL NO._______________ NO. DE SERIE __________________________  FECHA DE INSTALACION_____________

GRAPE SU RECIBO DE COMPRA AQUI

1

2

3

4

5

6

7

8, 9

10

12

13

14

15

Jet Pump

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or prop-
erty damage! Retain instructions for future reference.

Description

These pumps are single stage domestic
water pumps designed for pumping
potable water. Shallow well pumps are
designed for applications where the
water level is less than 25 feet below
the pump. Flammable liquids such as
gasoline, chemicals, or corrosive liquids
should never be used with these
pumps.

Unpacking

Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or com-
ponents are damaged, return the unit
to the place of purchase for replace-
ment. Failure to do so could result in
serious injury or death.

Safety Guidelines

This manual contains information that
is very important to know and under-
stand. This information is provided for
SAFETY and to PREVENT EQUIPMENT
PROBLEMS. To help recognize this
information, observe the following
symbols. 

Danger indicates 
an imminently haz-

ardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially haz-

ardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 

potentially haz-

ardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 
important informa-

tion, that if not followed, may cause
damage to equipment.

NOTICE

!

CAUTION

!

WARNING

!

DANGER

Operating Instructions and Parts Manual

JSU50

General Safety
Information

1.  Read these rules and instructions

carefully. Failure to follow these
instructions could cause serious
bodily injury and/or property 
damage.

This pump is non-

submersible.

Install indoors

only.  Risk of elec-

trical shock.

Pump only clear water. Do
not pump flammable or
explosive fluids such as
gasoline, fuel oil, kerosene, etc. Do not
use in a flammable and/or explosive
atmosphere. Personal injury and/or
property damage could result.

This pump is not 
designed to handle

salt water, brine, laundry discharge, or
any other application which may con-
tain caustic chemicals and/or foreign
materials. Pump damage could occur if
used in these applications and will void 
warranty.

All wiring must be per-
formed by a qualified elec-
trician. The pump must be
installed in compliance with
the National Electrical Code and all
local codes.

2.  Connect this pump to a grounded

circuit equipped with a ground
fault interrupter device.

3.  Before installing this product, have

the electrical circuit checked by an
electrician to ensure proper 
grounding.

Pump must be disconnected
from power source before
installing or servicing.

!

DANGER

!

WARNING

NOTICE

!

WARNING

!

WARNING

!

DANGER

311404-001  7/08

4. Be sure the water source and pip-

ing is clear of sand, dirt, and scale.
Debris will clog pump and void
warranty.

5.  Protect pump and piping from

freezing. Failure to protect from
freezing could cause severe dam-
age and will void the warranty.

6.  Follow priming instructions. Do not

run pump dry.

Installation

Protect pump from the elements by
installing in a basement, garage, tool
shed, or pump house. Install the pump
so the centerline of the pump is as
close as possible to the water level.
Keep installation area clear to provide
access for service and maintenance.
Protect the pump against flooding and
excess moisture.

Make sure the pump has adequate
ventilation. The surrounding tempera-
ture should not exceed 100˚F (38˚C) or
nuisance tripping of thermal overload
protector on the motor may occur.

PUMP PIPING INSTALLATION

Use new pipe for best results. Iron, 

To Water
Line

To
Well or
Cistern

Figure 1 - Pipe Installation

© 2008 Wayne Water Systems

For parts, product & service information

visit 

www.waynepumps.com

See Warranty on page 8 for important information about commercial use of this product.

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Summary of Contents for JSU50

Page 1: ...efully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result...

Page 2: ...s and Parts Manual Installation Continued copper or PVC pipe may be used To avoid strain on the pump when using iron or copper pipe provide indepen dent supports for both suction and dis charge piping...

Page 3: ...ELECTRICAL CONNECTIONS The voltage of power supply must match the voltage of the pump Above ground well pumps covered in this manual have dual voltage motors pre set at the factory to 230 volts The mo...

Page 4: ...alve The valve will discharge water if the bladder is broken 2 If bladder is broken replace tank Once a tank bladder is ruptured the tank should be replaced Repairing the bladder is not recommended an...

Page 5: ...no descarga agua en 5 minutos apague el motor y regrese al paso 1 AVISO ADVERTENCIA PRECAUCION 6 Deje que el sistema funcione durante algunos minutos para lavar las tuber as 7 Cierre la llave y deje...

Page 6: ...NADO 1 Accione la punta varios pies por debajo de la capa fre tica NOTA Se puede instalar una v lvula de pie tipo portadora en el pozo Figura 8 Este tipo de v lvula de pie permite que la tuber a del p...

Page 7: ...CONEXI N AL TANQUE DE AGUA TANQUE CONVENCIONAL FIGURAS 3 4 Un tanque de agua convencional almacena agua y aire comprimido en el mismo compartimiento Cuando el tanque est lleno ste contiene aproximadam...

Page 8: ...a s mismo y a los dem s observando la informaci n de seguridad El no cumplir con estas instrucciones podr a provocar lesiones personales y o da os materiales Conserve estas instrucciones para futura...

Page 9: ...1 Lire attentivement ces instructions et directives Manque de suivre ces instructions peut r sulter en blessures graves et ou en d g ts mat riels Cette pompe n est pas submersible Risque de Secousse...

Page 10: ...tion 2 Purger le r servoir Utiliser le robinet plus pr s du r servoir 3 S assurer que le r servoir soit fix avec s ret au plancher ou la base 4 Boulonner la pompe au plancher ou sur le support de fixa...

Page 11: ...p cher d emprisonner l air dans les lignes CONNEXION LECTRIQUE La tension de la source d alimentation doit correspondre avec la tension de la pompe Les pompes de puits de surface couvertes dans ce man...

Page 12: ...n de faire la chasse d eau des tuyaux 7 Fermer le robinet et permettre que la pompe augmente la pression dans le r servoir Le moteur s arr tera quand la pression atteint le r glage d arr t Le syst me...

Reviews: