background image

SPECIFICATIONS

POWER SUPPLY REQUIREMENTS

120 V, 60 Hz

MOTOR

                           Single Phase

HORSEPOWER

1/2 HP ..................

(VIP50)

1/5 HP...................

(VIP15)

CIRCUIT REQUIREMENT

15 A (minimum)

LIQUID TEMPERATURE RANGE

40° F- 120° F

620007-001 B 08/18

© 2018, WAYNE/Scott Fetzer Company.

CONSTRUCTION

MOTOR HOUSING

Thermoplastic

MOTOR SHAFT

Stainless Steel

IMPELLER

Thermoplastic

VOLUTE

Thermoplastic

PUMP DISCHARGE

1-1/4 in. NPT or 3/4 in. Hose Threads

Submersible Multi-Use Pumps

www.waynepumps.com

PERFORMANCE

Model

HP

Discharge Head

0 ft. 

5 ft. 

10 ft. 

15 ft. 

20 ft.

VIP50

1/2

Gal/hr

2600

2160

1680

1080

300

VIP15

1/5

Gal/hr

2050

1740

1350

880

-

Please read and save these instructions. Read carefully before attempting to assemble, install,

operate or maintain the product described. Protect yourself and others by observing all safety

information. Failure to comply with instructions could result in personal injury and/or property

damage! Retain instructions for future reference.

    Operating Instructions and Parts Manual                                                                        VIP Series

Summary of Contents for VIP50

Page 1: ...ose Threads Submersible Multi Use Pumps www waynepumps com PERFORMANCE Model HP Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft VIP50 1 2 Gal hr 2600 2160 1680 1080 300 VIP15 1 5 Gal hr 2050 1740 1350 880...

Page 2: ...multi use pump is designed and in tend ed for non automatic use in water The units are equipped with an 8 ft 3 prong ground ing type power cord The motor is oil filled and sealed for cooler running a...

Page 3: ...event unexpected application of power Failure to do so COULD result in fatal electrical shock D brancher l alimentation avant de proc der l entretien Si la source de courant n est pas visible verrouil...

Page 4: ...ebout dans l eau ou sur une surface humide Ne JAMAIS toucher la pompe ou la tuyauterie d vacuation lorsque l unit fonctionne ou ne fonctionne pas correctement TOUJOURS d brancher le cordon d alimentat...

Page 5: ...s concessionnaires ou des lectriciens qualifi s peuvent essayer de r parer cet appareil Une r paration inad quate POURRAIT provoquer un risque de choc lectrique 1 No oiling is required for this pump T...

Page 6: ...ture 2 Pump has run dry or insufficient fluid level for pump to prime 3 Low supply voltage 1 Pump should not be used in water above 120 2 Reposition pump in adequate water pump uses water for cooling...

Page 7: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE W...

Page 8: ...www waynepumps com 8 NOTES...

Reviews: