Operating Instructions and Parts Manual
8
TROUBLE SHOOTING CHART
Symptom
Possible Cause(s)
Corrective Action
Pump will not start or run
1. Blown fuse or breaker
1. Check pump housing or power cord
for damage, before replacing fuse or
resetting breaker. If in doubt call an
electrician
2. Low supply voltage
2. Contact an electrician
3. Worn motor
3. Replace pump
4. Impeller not rotating (jammed)
4. If impeller will not turn, disconntect
pump from power source and remove
blockage (see Volute and Impeller
Cleaning Instructions)
5. Thermal protector open
5a. Water temperature is too high, allow
water to cool before pumping
b. Inlet clogged, remove debris
c. Motor seized, replace pump
d. Discharge clogged or hose kinked/
clogged. Clear blockage
Pump starts but delivers little or no
fl ow
1. Inlet clogged
1. Clean debris from exterior of volute
and all debris fi ltering features
2. Low supply voltage
2. Contact an electrician
3. Restriciton in discharge hose
4. Discharge lift too high
3. Unwind garden ose, remove any
kinks or restrictions in hose
4. Water level to end of garden hose is
25 ft. or greater, reduce vertical lift.
5. Impeller clogged
5. Disconnect pump from power source
and remove blockage(see Volute and
Impeller Cleaning Instructions)
LIMITED WARRANTY
For one year for WWB 2 model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser,
any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship.
Please call Wayne Water Systems (866-928-7284) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this
warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance,
or failure to operate in accordance with Wayne Water Systems’ written instructions.
THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM
COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE
AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH
THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT
(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES.
You
MUST
retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you
MUST
send a
copy
of the purchase receipt along
with the material or correspondence. Please call Wayne Water Systems (866-928-7284) for return authorization and instructions.
DO NOT MAIL THIS FORM TO Wayne Water Systems.
Use this form only to maintain your records.
MODEL NO._____________________ SERIAL NO._________________________ INSTALLATION DATE __________________________
ATTACH YOUR RECEIPT HERE
QUICK START INSTRUCTIONS
WWB 2
For product & service information
visit www.waynepumps.com
READ THIS MANUAL BEFORE USING THIS PRODUCT. FAILURE TO FOLLOW THE INSTRUCTIONS AND SAFETY PRECAUTIONS
IN THIS MANUAL CAN RESULT IN SERIOUS INJURY OR DEATH. KEEP THIS MANUAL FOR FUTURE REFERENCE.
© 2018, WAYNE/Scott Fetzer Company.
STEP 3 - REMOVE DISCHARGE CAP
STEP 4 - ATTACH GARDEN HOSE TO BRASS DISCHARGE
STEP 5 - PLACE IN WATER
STEP 6 - ALWAYS PLUG INTO GFCI OUTLET. UNPLUG PUMP
WHEN WATER IS NO LONGER BEING MOVED. DO NOT RUN
PUMP DRY FOR EXTENDED PERIOD OF TIME.
FOR FURTHER INSTRUCTIONS, DOWNLOAD OWNER’s
MANUAL ONLINE
www.waynepumps.com/product/wwb
STEP 1 - GET TO KNOW YOUR PUMP
• 10 FT. POWER CORD
• TOP DISCHARGE
• SIDE DISCHARGE
• CORD WRAP
• CORD CLIP
• HANG LOOP
STEP 2 - CHOOSE THE DISCHARGE BEST FOR THE
APPLICATION
• TOP DISCHARGE
is perfect for water
removal in tight spaces:
Laundry Tubs,
Window Wells, Buckets, etc.
• SIDE DISCHARGE
is ideal for easy
water removal from at open surfaces:
Flat Roofs, Flooded Basements, standing
water in yard, crawl spaces, etc.
• WARNING DECAL
Removes water down to
1/16 in. of surface,
VIRTUALLY DRY!
TWIST
TIP: Unwind and remove all kinks
and bends in hose for more ef cient
pumping and priming.
Requires 3/16 in. of water
to start pumping.
620011-001 B 08/18
•
•
CARRYING HANDLE
•
•
-OR-
-OR-
®