background image

 

 
 
 

 

 

 
 

 

Installation and Startup Guide

 

This document covers the installation of cMT-iM21, for the detailed specifications and operation, please 
refer to Datasheet, Brochure and User Manual. Please read all warnings, precautions, and instructions on 
the device carefully before use. 

Install Environment: 

Electrical 

Environment

 

The cMT-iM21 Series has been tested to conform to European CE requirements. 

This means that the circuitry is designed to resist the effects of electrical noise. 

This does not guarantee noise immunity in severe cases. Proper wire routing and 

grounding will insure proper operation.

 

Environmental 

Considerations

 

(1)  Make sure that the units are installed correctly and that the operating limits 

are followed. Avoid installing units in environments where severe 

mechanical vibration or shocks are present. 

(2)  Do not operate the unit in areas subject to explosion hazards due to 

flammable gases, vapors or dusts.

 

(3)  Do not install the unit where acid gas, such as SO2 exists. 

(4)  This device should be mounted in the vertical position and for use on the flat 

surface enclosure.

 

(5)  Relative Humidity: 10% ~ 90% (non-condensing)

 

Cleaning 

Considerations 

Clean the device using dry cloths. Do not use liquid or spray detergents for 

cleaning. 

IP rating 

IP 65 

Warning 

Protection impairment if used in a manner not specified by the manufacturer. 

Déficit de protection si utilisé d'une manière non spécifiée par le fabricant. 

 

Unpacking the Unit

 

Unpack and check the delivery. If damage is found, notify the supplier.   

NOTE: Place the unit on a stable surface during installation. Dropping it or letting it fall may cause 

damage. 

(1)  Installation Instruction, 2-sided A4 *1 

(2)  cMT-iM21 *1 

(3)  Panel mount kit 

 

 

 

 

 

 

 

 

Installation Instructions 

Use a control box that provides enough stiffness. Cutout Dimension: 532 mm x 340 mm. Secure the 

operator panel in position, using all the fastening holes and the provided brackets and screws. Screw 

Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel from being deformed.) 

Plan for adequate space around the unit and inside the enclosure, for ventilation and cables. Consider the 

heat from other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C 

Minimum required clearances (along the overlay): Top 20 mm / Bottom 20 mm / Sides 20 mm 

Maximum panel thickness: 3 mm 

 

VESA Mount 100 x 100 (M4 Max. Depth 8mm)

 

 

 

Power Connections 

NOTE: Connect po

sitive DC line to the ‘+’ terminal and the DC ground to the ‘-’ terminal. 

 

 

 

 

Type 

A(mm) 

B(mm) 

cMT-iM21 

532 

340 

cMT-iM21 series 

 

Installation Instruction 

 

(A) 

(B) 

Cutout 