Installation and Startup Guide
This document covers the installation of cMT-iM21, for the detailed specifications and operation, please
refer to Datasheet, Brochure and User Manual. Please read all warnings, precautions, and instructions on
the device carefully before use.
Install Environment:
Electrical
Environment
The cMT-iM21 Series has been tested to conform to European CE requirements.
This means that the circuitry is designed to resist the effects of electrical noise.
This does not guarantee noise immunity in severe cases. Proper wire routing and
grounding will insure proper operation.
Environmental
Considerations
(1) Make sure that the units are installed correctly and that the operating limits
are followed. Avoid installing units in environments where severe
mechanical vibration or shocks are present.
(2) Do not operate the unit in areas subject to explosion hazards due to
flammable gases, vapors or dusts.
(3) Do not install the unit where acid gas, such as SO2 exists.
(4) This device should be mounted in the vertical position and for use on the flat
surface enclosure.
(5) Relative Humidity: 10% ~ 90% (non-condensing)
Cleaning
Considerations
Clean the device using dry cloths. Do not use liquid or spray detergents for
cleaning.
IP rating
IP 65
Warning
Protection impairment if used in a manner not specified by the manufacturer.
Déficit de protection si utilisé d'une manière non spécifiée par le fabricant.
Unpacking the Unit
Unpack and check the delivery. If damage is found, notify the supplier.
NOTE: Place the unit on a stable surface during installation. Dropping it or letting it fall may cause
damage.
(1) Installation Instruction, 2-sided A4 *1
(2) cMT-iM21 *1
(3) Panel mount kit
Installation Instructions
Use a control box that provides enough stiffness. Cutout Dimension: 532 mm x 340 mm. Secure the
operator panel in position, using all the fastening holes and the provided brackets and screws. Screw
Torque: 2.6 ~ 3.9 lbf.in. (For reaching waterproof effect and preventing the panel from being deformed.)
Plan for adequate space around the unit and inside the enclosure, for ventilation and cables. Consider the
heat from other devices inside the enclosure. The ambient temperature around the unit must be 0 ~ 50°C
Minimum required clearances (along the overlay): Top 20 mm / Bottom 20 mm / Sides 20 mm
Maximum panel thickness: 3 mm
VESA Mount 100 x 100 (M4 Max. Depth 8mm)
Power Connections
NOTE: Connect po
sitive DC line to the ‘+’ terminal and the DC ground to the ‘-’ terminal.
Type
A(mm)
B(mm)
cMT-iM21
532
340
cMT-iM21 series
Installation Instruction
3
4
1
2
(A)
(B)
Cutout