Installation Instruction 

 

1.0 Installation and Startup Guide   

Install Environment 

 

Where  
Used

 

The MT-600/8000 Series is designed for industrial. The temperature range of operating 
is from 32 to 113 °F (0 to 45 °C) , as majority of industrial environments. It may not 
be suitable for using in certain outdoor applications. Please consult the factory for 
advised usage in outdoor applications. 

NEMA 
Rating 
 

The MT-600/8000 Series front bezel is NEMA 4 rated. When installed properly in a 
NEMA 4 panel, the NEMA 4 rating of the panel will not be compromised. This means 
that fluids will not enter the panel during wash downs. 

Electrical 
Environment 

The MT-600/8000 Series has been tested to conform to European CE requirements. 
This means that the circuitry is designed to resist the effects of electrical noise. This 
does not guarantee noise immunity in severe cases.    Proper wire routing and 
grounding will insure proper operation. 

Mechanical 
Environment 

 
 
 
 

Avoid installing units in environments where severe mechanical vibration or shocks 
are present. 

2.0 Installation Instructions 

2.1 Mounting Instructions 

 

2.1.1 Location Considerations 

 

Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC 

output modules, contactors, starters and relays, and any other source of electrical interference are located 
away from the back of the unit. 

 
Particular note should be taken to the position of variable speed drives and switching power supplies. 

Their input and load cables should be screened to a central star earth point. 

 

Summary of Contents for MT-610 Series

Page 1: ...0 Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mechanical vibration or shocks are present 2 0 Installation...

Page 2: ...ent This will cause condensation of water in the device z Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to determine which codes apply 2 2 1 Power Requirements Power The MT 610X 8104X can be powered by DC power only The s...

Page 3: ...ected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an MT 600 8000 comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the chassis ground terminal of the power connector This ground connection should be run dire...

Page 4: ... authorized personnel can make such changes These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation z The ICS 3 304 81 Safety Recommendations are reproduced by permission of the National Electrical Manufacturers Associat...

Page 5: ...n assignment of the 9 Pin Male SUB D COM1 RS 232 and COM2 RS 232 Port Pin Designations COM1 RS 232 COM2 RS 232 Pin Symbol COM1 RS232 COM2 RS232 1 Not used 2 RxD Received Data 3 TxD Transmitted Data 4 TxD Transmitted Data 5 GND Signal Ground 6 RxD Received Data 7 RTS Ready to send output 8 CTS Clear to send input 9 Not used 2 4 2 Connector COM1 RS485 COM3 RS485 and COM3 RS232 The 9 Pin Female SUB D...

Page 6: ...r Wire MT8 Ethernet RZC045120 Direct connect Ethernet crossover cable MT8000 Ethernet RJ45 Wire color PC or Note Book RJ45 1 TX White Orange 3 RX 2 TX Orange 6 RX 3 RX White Green 1 TX 6 RX Green 2 TX MT8 COM1 RZC002320 1 5 6 9 5 9 1 6 6 9 1 5 MT8 COM3 RZC004850 5 9 1 6 1 5 6 9 1 5 6 9 5 9 1 6 ...

Page 7: ...cd m 2 Color 65 536 colors Contrast Ratio 300 1 Resolution WxH dots 640 x 480 Back light CCFLx2 CCFL life time 40 000 hr min Touch panel 4 wires resistive type Touch Accuracy 2mm Surface Hardness 4H I O port COM1 RS 232 RS 485 2W 4W COM2 RS232 COM3 RS 232 RS 4852W 1 Ethernet port 10 100 Base T SD CARD SLOT PS 2 Port Connector USB Host 2 USB Host port Audio 1 x Audio Line Out 1 x MIC In Processor A...

Page 8: ...28 43mm 1 69 COM1 RS232 COM2 RS232 COM3 RS485 COM3 RS232 COM1 RS485 2 4W SD PS 2 b a e f l m k j i h g g g g c d 50mm 1 97 A N A H SD CARD SLOT B IDE Interface DOM Slot I Com1 RS232 Com2 RS232 C Line Out J Com1 RS485 Com3 RS485 Com3 RS232 D Mic In K Ethernet Port 10 100 Base T E Fuse Reset Button L USB Host Port x 2 F Power Connector M PS 2 Port Connector G VESA 75mm Screw Holes Cutout Dimensions ...

Reviews: