background image

1

 

NP-610p series   

 

 

 

 

 

 

 

1.0 Installation and Startup Guide   

Install Environment 

 

Where   
Used
 

The NP-610p Series is designed for industrial. The temperature range of operating is 
from 14 to 113 °F (-10 to 45 °C), as majority of industrial environments. It may not be 
suitable for using in certain outdoor applications. Please consult the factory for 
advised usage in outdoor applications. 

NEMA 
Rating 
 

The NP-610p Series front bezel is NEMA 4 rated. When installed properly in a NEMA 
4 panel, the NEMA 4 rating of the panel will not be compromised. This means that 
fluids will not enter the panel during wash downs. 

Electrical 
Environment 

The NP-610p Series has been tested to conform to European CE requirements. This 
means that the circuitry is designed to resist the effects of electrical noise. This does 
not guarantee noise immunity in severe cases.    Proper wire routing and grounding 
will insure proper operation. 

Mechanical 
Environment 

 
 
 
 

Avoid installing units in environments where severe mechanical vibration or shocks 
are present. 

 

2.0 Installation Instructions 

2.1 Mounting Instructions 

2.1.1 Location Considerations 

 

Care should be taken when locating equipment behind the unit to ensure that AC power wiring, PLC 

output modules, contactors, starters and relays, and any other source of electrical interference are located 
away from the back of the unit. 

 

Summary of Contents for NP-610p Series

Page 1: ...the panel during wash downs Electrical Environment The NP 610p Series has been tested to conform to European CE requirements This means that the circuitry is designed to resist the effects of electrical noise This does not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where sever...

Page 2: ... are installed correctly and that the operating limits are followed See Specifications Do not operate the unit in areas subject to explosion hazards due to flammable gases vapors or dusts The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have in...

Page 3: ...al 2 2 2 Grounding Requirements Chassis ground must be used DC ground is not directly coupled to Earth ground internally It is preferable not to ground DC negative return to chassis ground as poor site earths can introduce noise into a system but if necessary an earth connection should be made from the power supply return point to the central star earth point Ground conductors should be as short a...

Page 4: ...ation consideration should be given to the use of locks or other means of assuring that only authorized personnel can make such changes These recommendations are intended as safeguards against the failure of critical components and the effects of such failures or the inadvertent errors that might be introduced if programs are changed while the equipment is in operation The ICS 3 304 81 Safety Reco...

Page 5: ...M3 RS 232 Port Pin Symbol Com1 RS485 2w Com1 RS485 4w Com3 RS485 CAN Bus 1 Rx Data Rx 2 Rx Data Rx 3 Tx Tx 4 Tx Tx 5 GND Signal Ground 6 Data Data 7 Can_L Can_L 8 Can_H Can_H 9 Data Data 2 3 3 USB Host port Support various devices with USB interface such as mouse keyboard USB stick printer etc 2 3 4 Connecter Wire NP 610p Ethernet NP 610p Ethernet RJ45 Wire color 1 TX White Orange 2 TX Orange 3 RX...

Page 6: ...efault password is 111111 However other passwords including download and upload password have to be reset Note When the reset action is be taken projects and saved data in the HMI will all be cleared 2 4 CE Requirements EU directives that apply to the NP 610p Series EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC electromagnetic emissions and immunity Machinery Directive 89 392 EEC 91 368 EEC 93 44 E...

Page 7: ...e T USB USB Host port x 1 USB Client port x 1 Processor 32bit RISC CPU 600MHz RAM 128MB Flash memory 128MB SD SDHC card slot Yes RTC Built in General Specification Input Power 24 20 VDC Max Power Consumption 400 mA 24VDC Power Isolation Inside Protection structure NEMA 4 IP65 front panel O ring seal Operating Temperature 0 50 C Operation humidity 10 90 RH non condense Enclosure Plastic Dimensions ...

Page 8: ...intek the product fails due to damage from shipment handling storage accident natural and man mad b if the product fails due to misuse including but not limit to incorrect set up and wiring current leakage from machine platform and incorrect input power c if the product has been maintained in a manner not conforming to product s instructions or has been modified in any way d if the serial number h...

Page 9: ...9 4 0 Dimensions of NP 610p Cutout dimensions ...

Reviews: