background image

 

 

 

 

 

 

 

 

 

 

WHIRLPOOL OF INDIA LTD 

 

 

 

 

 

 

 

 

 

 

 

 

 

       

 

 

 

 

 

 

 

 

 

         

 

 

 

 

 

 

                                                                                                                                                                 

                                                                                                                                                                                         

 

 

Service Manual 

Top Mount 

No Frost Refrigerator 

 

 

 

 

 

 

  

Summary of Contents for 240L SUSLITE

Page 1: ...1 WHIRLPOOL OF INDIA LTD Service Manual Top Mount No Frost Refrigerator ...

Page 2: ...ail Page No 1 MODEL RANGE 3 2 SAFETY PRECAUTIONS 4 3 FEATURE TECHNICAL SPECIFICATION 6 4 ELECTRONIC CONFIGURATION AND TROUBLESHOOTING 7 5 COOLING CONTROL 8 6 WIRING DIAGRAM 9 7 EXPLODED VIEWS 10 8 SERVICE PART LIST 14 ...

Page 3: ...3 NO FROST REFRIGERATOR MODEL RANGE 240L TITANIUM WIE90 SV 240L SUSLITE WIE90 SS 260L TITANIUM WIE100 SV 260L SUSLITE WIE100 SS ...

Page 4: ...4 ...

Page 5: ...5 ...

Page 6: ...r BT60 120Y BT60 120Y Fan motor MI AC MOTOR FOR DUO MI AC MOTOR FOR DUO Split Diffuser NO NO Deodorizer CHARCOAL CHARCOAL Number of Shelves 2 3 Type of Shelves GLASS GLASS Humidity Control YES YES RC Illumination BULB BULB FC Illumination Bottle Retainer 2 2 Can Rack NO NO Egg tray 12 EGGS 12 EGGS Removable Ice twister YES YES Puff pastry NO NO Freezer Door Bins 2 2 Refrigerator Door Bins 3 4 Door...

Page 7: ...e is a thermostat in RC compartment to set temp settings Product Configuration 240 260L dlx Product Control RC Controlled Software No User interface No Auto cool mode No Quick Chill Fast Forward Ice No Auto Power save mode No Door Alarm No RC Illumination Yes Lamp Control Board No Defrost heater Yes Radiant Heater 165 W Fan motor FAN MOTOR MI 160 260V Compressor ASD65 Run Capacitor Door Reversibil...

Page 8: ...If there is at least one door opening up to 8 hrs of compressor running then defrost time is as per point 1 5 If there is no door opening up to 8 hrs of compressor running than defrost time will be 18hrs 6 If there is no door opening for 8 hrs there is door opening between 8 to 18 hrs of compressor running defrost will take place immediately The 5th 8th or 18th hr of compressor running defrost tim...

Page 9: ...9 WIRING DIAGRAM ...

Page 10: ...10 EXPLODED VIEWS ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 ...

Page 14: ...Deadening Evaporator 1 EA 1 EA 1 EA 1 EA 16 A208873000B DRIER ASSEMBLY LOK RING 1 EA 1 EA 1 EA 1 EA 17 W10644840 COMPRESSOR SLEEVE R600a 4 EA 4 EA 4 EA 4 EA 18 A2119170000 BI METAL ASSY TOD 39TV 1 EA 1 EA 1 EA 1 EA 19 A2221470000 BULB APPLIANCE E14 1 EA 1 EA 1 EA 1 EA 20 W10631925 R600a L60 GENX BULB HOLDER ASSY 1 EA 1 EA 1 EA 1 EA 21 A2246450000 POWER CORD PHILIPPINES ONYX 1 EA 1 EA 1 EA 1 EA 22 ...

Page 15: ...471820 SCREW CAP PLENUM 2 EA 2 EA 2 EA 2 EA 56 W10474372 BRAND BADGE 85MM 1 EA 1 EA 1 EA 1 EA 57 W10549123 SHOULDER SCREW ABT TYPE 6 EA 6 EA 6 EA 6 EA 58 W10618295 DRIER HOLDER GENX L60 NEW 1 EA 1 EA 1 EA 1 EA 59 W10528520 PLATE LEVELLER ASSEMBLY GENX 1 EA 1 EA 1 EA 1 EA 60 W10537824 DEFROST WATER TRAY GEN X L60 1 EA 1 EA 1 EA 1 EA 61 W10658706 EVAPORATOR ASSEMBLY L60 GENX 1 EA 1 EA 1 EA 1 EA 62 W...

Page 16: ...EA 1 EA 1 EA 88 W10579573 EARTHING WIRE WITH RING TERMINAL 1 EA 1 EA 1 EA 1 EA 89 W10477266 SUMP BACK PART 2 EA 2 EA 2 EA 2 EA 90 W10477268 FRONT COVER SUB ASSY 2 EA 2 EA 2 EA 2 EA 91 A201885000A INNER EARTH ASSY PHILIPPINES 1 EA 1 EA 1 EA 1 EA 92 W10530157 GASKET SUB ASSY FC GENX 1 EA 1 EA 1 EA 1 EA 93 W10473470 PUSH IN GASKET B RC 242L GENX 1 EA 1 EA 0 EA 0 EA 94 W10473471 PUSH IN GASKET B RC 26...