Summary of Contents for 761883306

Page 1: ... n 761883306 ...

Page 2: ...dition and all local codes and ordinances Installation work and electrical wiring must be done by a qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s gu...

Page 3: ...lofion is not included Wall or roof caps used must have backdrafl damper Determine which outside venting method needs to be used NOTE If a non vented recirculating installation is desired follow instructions on Panel D The length of the ductwork and number of elbows should be kept to a minimum to provide efficient performance The size of the ductwork should be uniform Do Not install two elbows tog...

Page 4: ...rside of cabinet Use a saber saw to cut the openings for the ductwork Repeat for the underside of the top of the cabinet This will create slotted openings To vent through the roof with 3 l 4 x 10 rectangular ductwork mark a line 1 and 5 from the back wall on the underside of the cabinet Mark lines 5 1 J4 to the right and left of the centerline on the underside of cabinet that connect the lines jus...

Page 5: ...uld be facing up 3 n Remove knockout from the wiring opening rear or top to be used Do Not remove venting knockouts 5 1516 4 H Remove terminal box cover on range hood Injury Hazard More than one person is required to help with installation because of the weight and size of range hood Failure to follow this instruction could result in serious injury keyhole slot 5 n Lift range hood into final posit...

Page 6: ...lean filter light lens Place filter light lens in dishwasher or hot sudsy water to clean Non vented insfallafion Turn filter light lens so that charcoal filter pad is facing up Lift tabs and remove charcoal filter pad Discard charcoal filter pad Place filter light lens in dishwasher or hot sudsy water to clean Lift tabs and place new charcoal filter pad in filter light lens New charcoal filter pad...

Page 7: ...esigned to be repaired in the home F Damage to range hood caused by accident misuse fire flood act of God or use of products not approved by Whirlpool WHIRLPOOL CORPORATION SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES Some states do not allow the exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you This warranly gives yo...