background image

Summary of Contents for GS440LEMB0

Page 1: ...dimensions Cabinet dimensions requkements Installation steps Gas conversions if range does not operate if you need assistance service Moving the range www whM pooH corn Read and save these instructions iMPORTANT installer Leave installation hstructions with the homeowner Homeowner Keep Installation Instructions for future reference Read and save these instructions for local electrical inspector s ...

Page 2: ...re that the electrical installation is adequate and in conformance with National Electrical Code ANSI NFPA 70 latest edition _ and all local codes and ordinances Proper installation is your responsibility A qualified technician must install this range Make sure you have everything necessary for correct installation t is the installer s responsibility to comply with installation clearances specifie...

Page 3: ...ized Do not ground to a gas pipe Check with a qualified electrician if you are not sure range is properly grounded A 120 volt 60 Hz AC only 10 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided Electronic ignition systems operate within wide voltage limits but proper ground...

Page 4: ...e on longer runs may result in insufficient gas supply Usually LR gas suppliers determine the size and materials used in the system Pipe joint compounds made for use with LR gas must be used on pipe threads onl Flexible metal appliance connector If local codes permit a new AGA or CSA design certified 1 2 or 3 4 I D flexible metal appliance connector is recommended for connecting range to the gas s...

Page 5: ...k that the floor covering can withstand at least 200 F 93 C Use an insulated pad or 1 4 6 ram plywood under range if installing range over carpeting Anti tip bracket The floor mounted anti tip bracket must be installed To install the anti tip bracket supplied see page 3 and the anti tip bracket template instruction sheet i min clearance upper side cabinet to countertop 1 2 1 cm rain countertop spa...

Page 6: ...floor Longer screws are available from your local hardware store Operating position 5_ Remove cardboard shipping base from under range Remove storage drawer Use a 3 8 drive ratchet to lower rear leveling legs one half turn Use channel lock pliers to lower front leveling legs one half turn Before moving range across floor check that range is still on cardboard shipping base to protect floor coverin...

Page 7: ... and tighten connections Then check connections again Clean aii leak detection solution from gas connections Close broiler door Center the burner cap on burner base Burner cap should be level when properly positioned Place burner grates over burner pressure regulator j union manual gas iron shutoff valve pipe 90_elbow union nipple I 2 to 3 4 gas pipe Typical flexible connection pressure use pipe j...

Page 8: ...iver into the valve stem Turn the valve screw to obtain the smallest flame that will not go out when the control of a cold burner is quickly turned from HIGH to LOW Repeat for other cooktop burners as needed Check operation of oven burner Open oven door Remove oven bottom Remove two screws at the rear of the oven bottom Lift the rear of the oven bottom up and back until the front of the panel is a...

Page 9: ...n racks Check operation of oven broil burner 2 Follow the instructions for your type of oven controls NOTE A faint ticking sound will be heard while the oven burner lights The oven burner should light within 8 seconds f your range has an oven temperature control knob Push in and turn the oven selector control knob to BROIL Iftheburner fails to light due to air remaining in the gas line reset the o...

Page 10: ...fice Locate the L R gas _ _ _ spud orifice spud on the spud card on the back _ groove of range Orifice spuds are stamped with a number and marked with two color dots and a groove nut driver spud L R Gas Surface Propane rate Orifice burner BTU hr Number Left 8 000 Lao rear Left 12 000 L103 front Right 8 000 Lao front Right 5 000 L65 rear Color Marking Green Lt Blue Green Magenta Green Lt Blue Green...

Page 11: ...rifice spud honer _ range cooktop Locate the Natural gas orifice spuds on the spud card on the back of the range Orifice spuds are stamped with a number and marked with two color dots Natural gas orifice spud Natural Gas Surface Propane rate Orifice Color burner BTU hr Number Marking Left 9 500 N151 Blue rear Brass Left 13 500 N186 Blue front Orange Right 9 500 N151 Blue front Brass Right 5 000 Nl...

Page 12: ...ber is listed in your Use and Care Guide When you call you wiii need _ The range model number _ The range serial number Both numbers are listed on the model serial rating plate located on the oven frame behind the storage drawer Moving the range Tip Over Hazard A child or adult can tip the range and be kH ed Connect anti tip bracket to rear range foot Reconnect the anti tip bracket if the range is...

Reviews: