BATHROOM  VENTILATION  HEATER

OPERATION MANUAL 

     

HB116

Warning: In order to prevent damage or accident, this machine must be installed by those qualified 

technician recognized by the government.

Please read this Operation Manual carefully before using this machine

HB124

Summary of Contents for HB116

Page 1: ...RATION MANUAL HB116 Warning In order to prevent damage or accident this machine must be installed by those qualified technician recognized by the government Please read this Operation Manual carefully before using this machine HB124 ...

Page 2: ...re of them Warning When there is no responsible person close by please do not let those disabled stay alone in the room with the machine When clean this machine please shut off the machine and and wait until the product completely stops working Please do not pull the wire It may cause damage of the wire or electrical leakage When some smell or noise occurs do stop using the machine and Do not put ...

Page 3: ...rience and knowledge including children or person must be under supervision and guidance by a dedicated person using this product Unless be strictly regulated children should be kept away from This product can only be used for personal indoor heating Never use this for heating liquid or other substances Do not let the kids or pets come close to this machine Do not let the kids operate this machine...

Page 4: ...ting Do not install too close to the electrical outlet in order to prevent damage of the machine for it may cause damage of other electrical appliances Prohibit using any programmes or timer automatically connected to the power or any other devices to use this product Otherwise it will cause damage to the product or fire Do not install this product near curtains and other flammable materials to pr...

Page 5: ...display area Air inlet cover Air outlet joint Automatic louver Screw cover Pre filter Signal receiver Front panel Frequency button Main body Ionizer Oscillation Super Hi Lo 04 Dry 乾燥功能 Heat 暖氣功能 Quick Heat 速暖功能 Fan 涼風功能 Vent 換氣功能 Vent 24Hr 24小時換氣功能 Heat Fan Vent 24 Hr 2 Hr 8 Hr Lo Air Volume Time setting display 6 sense 2 4 8 Hours th ...

Page 6: ...375mm 262mm TheAir outlet joint Exhaust pipe Air outlet joint Over 5cm Main body Over 50cm to the wall Front panel Self tapping screw 4 pieces Inspecttion opening Downdip 1 2 4 The minimum distance between the surrounding structures should be 50 cm Sc Screw hole 2 4 7 9 for Screw hole 3 05 1 Install the Fixed Frame to the ceiling Make the fixed frame Please use materials that can bear 6kg to fix t...

Page 7: ... 4 screw covers and use four screws to fix the Front Panel and the Main Body After having done the above please confirm the following inspection points 06 Whether the installation of the Front Panel is well fixed Whether the noise or shaken happen during operation Use tape or the filling to seal the junction between the exhaust pipe and the air outlet joint The exhaust pipe should have the tendenc...

Page 8: ...ce housing to the frame of the aluminum window must use the waterproof glue for the waterproof 3 After connecting the power cord embed the Main body into the hole with screws 4 The minimum distance between the surrounding structures should be 50 cm C Window type method Power and the outlet hole of remote control Water resistance housing Nails fixed hole Power and the remote control wire joint plac...

Page 9: ...mm Thickness of the Main Body 164mm 5 The minimum distance between the surrounding structures should be 50 cm Installation Method D Wall mount type method Installation of the Remote Control 1 2 3 1 Fix the remote control frame to the designated place and make marks according to the arrows Dig holes 1 4 6 mm according to the mark and fill the holes with four plastic plugs 3 Put the remote control i...

Page 10: ...trol Frequency button Operation light Mulfunction light The air quality indicator The main body panel display picture right down part 09 1 Check if the Main Body has connected to the power supply and the remote control with battery 2 Press the frequency matching button the right down of the main body panel for 3 seconds the buzzer will ring three times If the operation light green light and the mu...

Page 11: ...should be consistent with air switch off contact all disconnected requirements of distance is greater than 3 mm power of the product immediately in case of accident 2 Installation and wiring of power must be performed by qualified electrical engineering contractor 3 Please use this product under rated voltage and rated frequency in accordance with the product nameplate 4 When installing the fixed ...

Page 12: ...er High Speed Run High Speed Run High Speed Run High Speed Run Low Speed Run Low Speed Run Deodorization Deodorization Air Exhaust Air Exhaust Simultaneously ON or OFF with the Circulation Fan Operation Mode Circulation Fan Exhaust Fan HEATER Default 6 Others FUNCTION APPLICATION Blade Swing Ionizer Ionizer Output Swing AUTO UP DOWN Manual Left Right Bathroom Cooling Dry High 3 Dry Super Dry Low H...

Page 13: ...sappear and the product will stop automatically and the VENT Function High Low Press the Vent button the LCD will display Vent icon air volume will run the High mode Press the button again to inter change the Hi or Lo mode Timer the default time is 2 hours By pressing Timer up or down button to select time duration The time can be set from 15 minutes to 24 hours The time counter will be displayed ...

Page 14: ...disappear and the product will stop automatically When the heater stops running the fan will continues runs for around 25 seconds to cool down the heater Function Descriptions 5 DE ODOR Function 6 Sense 2hr 4hr 8hr th Press De odor button it will start the deodorization function The default mode will run in 6 Sense mode Press the button again you can choose any of the other 3 mode which are 2hours...

Page 15: ...l stop automatically Delay Vent Function 14 Start default running the On and Off operation same with Fan If it is ON LCD icon will displaced and icon will disappear when it is off When it is off the swing function is invalid and the louver will resume to 0 degree position When it is fan mode the default is 90 degree louver position Auto Swing when the fan is running press the Swing button the louv...

Page 16: ...llowing symptoms and abnormal situation occur please switch off the electricity and ask qualified electrical engineering contractor for repairement or check self repair by user is strictly prohibited to avoid danger Do not put your hands into the machine when running to avoid from injury or burn by the heater To maintain the filter effectiveness to adsorb peculiar smell we suggest that you collect...

Page 17: ...y fixation 2 Ceiling type Hardware packs Usage Specification Amount Picture Fixed remote control 1 Standard setting 3 Hung to wall type Screw Adjusting Hung to wall support Watertight casing on Screw Plastic plug Fixed Nut Fixed Screw Adjusting nut Screw Stainless Name SUS 4 25 Φ9 Round head Φ8 27 ST M6 ST M6 ST Φ6 Φ8 27 4 4 9 4 4 4 4 4 Nut list setting setting 4 Window type setting installation t...