Summary of Contents for SC8720EDB0

Page 1: ... Use and Care Guide for a toll free number to call or call the dealer from whom you purchased the cooktop when you Have questions about the cooktop installation or operation Need to obtain the name and number of an authorized service company The dealer is listed in the Yellow Pages of your phone directory under Appliances Household Major Service and Repair When you call you will need The cooktop m...

Page 2: ... in mobile homes Copies of the standards listed may be obtained from National Fire Protection Association Batterymarch Park Quincy Massachusetts 02269 Page 1 28 7 8 73 3 cutout width 20 15 16 53 2 cm cutout depth Cabinet drawers under the cooktop will need to be removed and the drawer fronts installed permanently on front of cabinet 15 16 2 4 cm minimum distance to backsplash or vertical wall 1 7 ...

Page 3: ...rounding wire is used it is recommended that a qualified electrician determine that the grounding path is adequate A 120 volt 60 Hz AC only 15 or 20 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided Electronic ignition systems operate within wide voltage limits but proper ...

Page 4: ...essure 14 inches WC Line pressure testing above 1 2 psi gauge 14 WC The downdraft cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psi 3 5 kPa Line pressure testing at 1 2 psi gauge 14 WC or lower The downdraft cooktop must be isolated from the gas supply piping system by cl...

Page 5: ...2 cm _3 1 4 x 10 flat elbow 12 ft 366 cm 3 1 4 x 10 90 elbow 5 ft 152 cm transition to round 5 to 6 1 ft 30 5 cm air flow 1 4 x 10 to 6 90 elbow 9 ft 274 cm air flow 1 4 x 10 to 6 4 5 ft 137 cm transition to flat 5 to 3 1 4 x 10 90 elbow 6 ft 183 cm ir flow this direction not recommended air flow to 3 1 4 x 10 90 elbow 5 ft 152 cm air flow 6 to 3 1 4 x 10 1 ft 30 5 cm _air flow wall cap 3 1 4 x 10...

Page 6: ...ct must end with a wall or roof cap outside the building Gas connection Fire Hazard Do Not make the connection too tight The regulator is die cast Making the connectiontoo tight may crack the regulator resulting in a gas leak and possibleexplosion or fire Do Not use an open flame to test for leaks from gas connections Checkingfor leaks with an open flame may result in a fire or explosion All conne...

Page 7: ...not go out Turn control knob to OFF position Repeat if necessary for other surface burner Check operation of left side surface burners or optional grill module 3 use module instructions to install left side surface burner or optional grill module Surface burners module Push in and turn right surface burner control knob to LITE position The flame should light within 4 seconds Turn the control knob ...

Page 8: ...s drill size 66 orifice alia 0 033 Install on LEFT rear and front burners Blue colored orifice hoods drill size 63 orifice alia 0 037 Install on RIGHT rear and front burners Place Natural gas hoods in plastic parts bag for future use Reattach bag to plenum Complete installation Sections D through E L P gas flames have slightly yellow tips in addition to the other proper characteristics Natural gas...

Page 9: ...tripped or the house fuse blown Check that the power supply cord is plugged into the wall receptacle Check that the gas supply valves are turned to the ON position See Use and Care Guide for troubleshooting list If you need assistance Check your Use and Care Guide for a toll free number to call or call the dealer from whom you purchased this appliance The dealer is listed in the Yellow Pages of yo...