OPERATING AND INSTALLATION INSTRUCTIONS

 FOR WHISPAIR RANGEHOODS 

UTILISING REMOTE FAN MOTOR UNITS

A I R   E N G I N E E R E D

Summary of Contents for X3M06S5

Page 1: ...OPERATING AND INSTALLATION INSTRUCTIONS FOR WHISPAIR RANGEHOODS UTILISING REMOTE FAN MOTOR UNITS A I R E N G I N E E R E D ...

Page 2: ......

Page 3: ...M TO ENSURE THAT IT HASN T BEEN DAMAGED IN TRANSIT OR IS MISSING ANY COMPONENTS FAILURE TO REPORT ANY ISSUE WITHIN 72 HOURS OF RECEIPT OF YOUR ITEM MAY RESULT IN ADDITIONAL CHARGES TO AVOID THE RISK OF INJURY OR DAMAGE TO THE PRODUCT IT IS ESSENTIAL TO READ THESE INSTRUCTIONS PRIOR TO INSTALLATION AND USE IMPORTANT INFORMATION Information on disposal for users Most of the packing materials are rec...

Page 4: ...X5L09S5 X5S09S5 X5V09S5 X5R09S5 X5M10S5 and X5N12S5 INCLUDED IN THE CARTON 1 Main hood housing including switch control and led lighting 2 Baffle filters 3 Grease trap 4 Stainless steel chimney 2x 5 Chimney bracket 6 Wall mounting bracket 7 Fixing screws 8 Operating installation guide OPTION 3 ISLAND HUNG CANOPY HOOD MODELS INCLUDED X7S09S5 X7V09S5 X7R09S5 and X7N12S5 INCLUDED IN THE CARTON 1 Main...

Page 5: ...HOOD MODELS INCLUDED X9C12S5 and X5C10S5 INCLUDED IN THE CARTON 1 Main hood housing including switch control and led lighting 2 Baffle filters 3 Grease trap 4 Mounting Beams 2x 5 Threaded rod 4x and nuts 6 Fixing screws 7 Operating installation guide 3 ...

Page 6: ...DELS INCLUDED EL 800 EP 1140 and EPP 2010 Unit designed to be mounted externally either on an external wall vertically mounted or penetrating through the roof horizontally mounted INCLUDED IN THE CARTON 1 KLEENAIR External fan motor unit 2 Pipe Clamps 200mm 2x 3 200mm Flexi duct 5 meters in length 4 Mounting screws for wall installation 5 Foam liner for wall installation OPTIONAL INSTALLATION ACCE...

Page 7: ...ng use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance There shall be adequate ventilation of the room when the range hood is used at the same time as appliances burning gas or other fuels The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels ...

Page 8: ...anufacturer does not guarantee performance when the duct length is greater than six 6 metres Ensure that all ducting is correctly fitted and sealed with pipe clips duct tape or silicone to ensure that fumes do not escape prior to reaching the KLEENAIR fan motor unit The WHISPAIR extraction calculations are based upon a 50pa change of head of pressure loss and are used to factor the variance of air...

Page 9: ...gher 7 Extraction Level versus Noise Level Cubic Meters Hour of Air Movement m3 hr 600 1200 1800 A 700 B 800 C 1140 D 2010 Sound Pressure Level 10 20 30 40 50 60 70 0 dB Extraction Level Comparison Cubic Meters Hour of Air Movement m3 hr 600 1200 1800 Change in Pressure 100 200 300 400 500 600 700 0 Pa A Standard premium rangehood found in the Aus NZ market offering 700 m3 hr B KleenAir Lite Unit ...

Page 10: ...nstallation STEP 2 Refer to Part 2 Motor Installation Guide STEP 3 Remove the three 3 screw fixings from within the Main Chassis of the rangehood located along the rear chassis wall located above the grease trap along with two 2 screws on the left side and two 2 screws on the right side Once the screws are removed the Fascia will separate away from the Main Chassis STEP 4 Fixing Holes are located ...

Page 11: ...imply locate the filter on the top ledge of the hood and then slide the filter on a downward angle to rest in the channel of the grease trap Ensure the filter vane are aligned towards the rear of the hood Step 7 Insert Fascia into Main Chassis Most by products are captured and stored directly in the baffle filters however the grease trap may begin to fill when excess amounts of grease and condensa...

Page 12: ...l centre line on the wall where the Mounting Bracket needs to be positioned It is recommended to centre the hood unit to the cooktop below STEP 3 Mark a horizontal line on the wall for the Mounting Bracket position Centre and mark the four 4 fixing points in the vertical section on the left and right side of the bracket Drill and plug holes with suitable sized wall plugs not provided STEP 4 Fix th...

Page 13: ...filtration system is used to catch by products such as grease and moisture from the air flow To install the baffle filters simply locate the filter on the top ledge of the hood and then slide the filter on a downward angle to rest in the channel of the grease trap Ensure the filter vane are aligned towards the rear of the hood Most by products are captured and stored directly in the baffle filters...

Page 14: ...to installation STEP 2 Place the two 2 supplied supporting metal beams 1000mm long with pre drilled fixing holes perpendicular 90o to the roof trusses STEP 3 Fit the four 4 supplied 10mm threaded rod through the holes provided on the supporting metal beams and secure with nuts and washers provided Ensure the rod drop height is sufficient to attach the hood and nut fixings but is not excessive that...

Page 15: ...he hood unit as possible INSTALLING THE GREASE TRAP AND BAFFLE FILTERS All WHISPAIR hoods utilise removable baffle filters and grease trap This filtration system is used to catch by products such as grease and moisture from the air flow To install the baffle filters simply locate the filter on the top ledge of the hood and then slide the filter on a downward angle to rest in the channel of the gre...

Page 16: ...dimension may vary from state to state please check with your local council prior to installation STEP 2 Place the two 2 supplied supporting metal beams 500mm long with pre drilled fixing holes perpendicular 90o to the roof trusses STEP 3 Fit the four 4 supplied 10mm threaded rod through the holes provided on the supporting metal beams and secure with nuts and washers provided Ensure the rod drop ...

Page 17: ... trap This filtration system is used to catch by products such as grease and moisture from the air flow To install the baffle filters simply locate the filter on the top ledge of the hood and then slide the filter on a downward angle to rest in the channel of the grease trap Ensure the filter vane are aligned towards the rear of the hood Most by products are captured and stored directly in the baf...

Page 18: ...ached to Internal Hood Unit Outlet Ducting Pulled Tight Gentle Bend In Ducting EXTERNAL KLEENAIR MOTOR SOLUTION Roof Upper and Wall Lower Mounted Roof Wall Fan Power Supply Attached to Internal Hood Unit 200mm Ducting Attached to Internal Hood Unit Outlet Gentle Bend In Ducting Ducting Pulled Tight INLINE KLEENAIR MOTOR SOLUTION Eave Upper and Wall Lower Vented Vent Eave Fan Power Supply Attached ...

Page 19: ...e top of the unit Ensure the direction of airflow is toward the outside The direction of airflow is marked on the KLEENAIR unit STEP 3 Cut a 200mm diameter hole in the wall or eave to enable the mounting of the external vent Please ensure that the hole is cut in a practical position to enable the flexi duct to be secured Attach the flexi duct to the vent and then mount vent to the wall or eave STE...

Page 20: ...om your KLEENAIR unit by twisting the cover in an anti clockwise direction Mark at least four mounting points on the wall and pre drill the holes required STEP 3 The rigid duct may require cutting to suit your particular wall thickness Attach the flexi duct to the rigid duct on the back of the mounting bracket using the pipe clamps supplied STEP 4 Fix the mounting bracket to the wall using the scr...

Page 21: ...ptional Accessory HBX200TILE or HBX200MET mount the rigid duct to beams trusses or other appropriate structures in the roof space Ensure the rigid duct protrudes past the top of the flashing by at least 75mm Max 150mm Min 75mm STEP 3 Remove the mounting bracket from your KLEENAIR unit by rotating the cover in an anti clockwise direction STEP 4 Fix the mounting bracket to the rigid duct using the s...

Page 22: ...TURNING THE LIGHT FUNCTION ON OR OFF Press button 1 to turn on or turn off the light independently in standby mode TURNING THE TIMER FUNCTION ON OR OFF In operating mode press button 4 to engage the timer function then press button 2 or 3 to adjust the delay time The default timer is set to 10mins and can be increased in increments of 10mins up to 1 hour i e 4 pushes of button 3 will result in tim...

Page 23: ...NING THE BAFFLE FILTERS AND GREASE TRAP The baffle filters and grease trap can be removed from the mounted position within the hood and washed in the dishwasher or by hand Use hot water and liquid detergent After cleaning leave the filters and trap to dry before placing back in the hood WARNING WHEN CHANGING THE LED LAMP Please be aware that whilst in use LED lighting units may become hot and the ...

Page 24: ... product in Australia simply call Haus Group Australia on 61 0 3 8593 9600 or New Zealand on 64 0 9 887 6959 to speak with our friendly customer service team consultants We suggest you have the following information close at hand to make the process as easy as possible 1 Model number of your complete rangehood and motor unit 2 A copy of your WHISPAIR proforma invoice 3 Address details of where the...

Page 25: ...23 NOTES ...