background image

CEILING MOUNT

ADDENDUM

2/3/2020

Ceiling Mount 4000
Ceiling Mount 8000

Ceiling Mount Twin

Summary of Contents for Ceiling Mount 4000

Page 1: ...CEILING MOUNT ADDENDUM 2 3 2020 Ceiling Mount 4000 Ceiling Mount 8000 Ceiling Mount Twin...

Page 2: ...not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice V...

Page 3: ...TABLE OF CONTENTS Filter 3 Line Set Drain Tube and Electrical Connections 4 Additional Access Holes 4 2 Speed Switch 5 Insulation Blanket Installation 6 Wiring Diagrams 8...

Page 4: ...et This includes the cavity between the ceiling joists A warm attic environment will reduce the capacity of the cooling system as the system will absorb heat from the attic in addition to the heat loa...

Page 5: ...www whisperkool com Page 3 Ceiling Mount Addendum Washable filter is installed from the factory on the return side of the grille secured via Velcro strips FILTER...

Page 6: ...fy there are no leaks before beginning vacuum and charging process ADDITIONAL ACCESS HOLES Top access holes 1 large hole for line set 1 small hole for electrical Note do not run electrical wiring thro...

Page 7: ...ED SWITCH The WhisperKool Ceiling mount now comes equipped with a 2 speed fan switch Located on the electrical panel Access by removing grille and internal access panel Speed is sent from factory set...

Page 8: ...es of the evaporator unit see illustration 5 Using a utility knife cut holes in the insulation for the line set wiring and drain line if needed 6 If necessary cut the insulation to size using the top...

Page 9: ...ion is installed apply foil tape to all seams covering them completely 11 Inspect insulation for damage defects If damaged repair with foil tape 12 Apply cork tape or equivalent to areas where the lin...

Page 10: ...Thermostat RC Field Installed LEGEND Factory Installed Solenoid or Compressor Relay Blue Black Black 146mm AFL Blower GREEN BLACK WHITE YELLOW BROWN GREY Capacitor BLUE 1 2 3 CONDENSATE PUMP BLACK YEL...

Page 11: ...18 5 THERMOSTAT WIRES GOING TO SLAVE UNIT CM TWIN MASTER UNIT WIRING DIAGRAM Field Installed LEGEND Factory Installed YELLOW BLACK 146mm AFL Blower GREEN BLACK BLUE WHITE YELLOW BROWN GREY Capacitor B...

Page 12: ...WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com...

Reviews: