Page 1: ...User manual Doc no BA000868 Last updated 08 2021 Rev C wienet LR77 v2 Mobilerouter LTE ...

Page 2: ...mits of the statutory provision of the Copyright Act Any modification or abridgment of the docu ment is prohibited without the express written agreement of Wieland Electric wienet is a trademark of Wieland Electric Other product or brand names mentioned in this docu ment are brand trademarks or registered trademarks of their respective owners Usage of these names and trademarks by third parties fo...

Page 3: ...ety instructions 7 3 Router description 8 3 1 Introduction 8 4 Scope of delivery 9 5 Router design 10 5 1 Version 10 5 2 Article numbers 11 5 3 Basic dimensions of the metal housing 12 5 4 Mounting recommendations 13 5 5 Removal from DIN rail 14 5 6 User interfaces connectors 14 5 6 1 LED status indicators 15 5 6 2 Power connector PWR 16 5 6 3 Antenna connector ANT 17 5 6 4 SIM card reader 18 5 6 ...

Page 4: ...SH or Telnet 25 7 Technical data 26 7 1 Technical data of the router 26 7 2 Technical data of mobile modules 27 7 2 1 Technical data of LTE module supporting 450 MHz 27 7 2 2 Technical data of GPS 28 7 3 Technical data of processor 28 7 4 Technical data of I O port 28 7 5 Technical data of expansion port 28 8 Maintenance and troubleshooting 29 8 1 Maintenance 29 8 2 Troubleshooting 29 8 3 FAQ 29 9...

Page 5: ...User manual The installation instructions accompanying the product is downloadable on the Wieland website Be sure to always use the information provided in the current version of this User manual The version and revision level can be seen in the title page and the footer 1 3 Target group This manual is aimed at planners engineers installers and service personnel who are planning a re mote control ...

Page 6: ...nch points etc It is used exclusively in danger of personal injury The symbol WARNING indicates a potential threat If it is not avoided it can result in death or seri ous injury could result The symbol CAUTION indicates a potential threat If it is not avoided slight or minor injury can re sult Refer to notes for special features of a device Instructions also tell you about a potentially harmful si...

Page 7: ...zation of accessories that have not been approved may result in damage to the router and in a breach of applicable regulations Unauthorized modifications or utilization of accessories that have not been approved may result in the termination of the validity of the guarantee The router cannot be opened Before handling the SIM card turn off the router and disconnect it from power supply Caution The ...

Page 8: ...NET I O USB Host PORT1 PORT2 SIM1 SIM2 LR77 v2 Basic version LR 77 v2c Compact version LR77 v2f Full version Configuration is done via web interface protected by password The LR77 LTE router supports crea tion of VPN tunnels using technologies IPsec OpenVPN L2TP to ensure safe communication The Web interface provides detailed statistics about the router activities signal strength detailed log etc ...

Page 9: ...VERY Basic delivery set of the router includes router external antennas clips for the DIN rail assembly instruction In addition to the basic components the following items can be ordered Accon NetLink Pro MPI to Ethernet adapter for S7 Remote Support different antennas power supply ...

Page 10: ... LR77 v2 SL Metal LR77 v2c SL Metal LR77 v2f SL Metal Standard optional with interface modules Table 2 Port1 options Module can be connected as follows PORT1 RS 232 RS 485 422 Ethernet M Bus CNT 3 Port Switch together with PORT2 PORT2 RS 232 RS 485 422 M Bus WIFI WLAN 3 Port Switch together with PORT1 Figure 1 Front panel LR77 v2B SL Figure 2 Front panel LR77 v2F SL ...

Page 11: ...VRRP DynDNS NTP SSH SMS eMail automatic update Article number Port 1 Port 2 Housing 83 041 0050 1 Metal 83 041 0055 1 Ethernet Metal Full version Mobile router LTE wienet LR77 v2f SL wienet mobile router LTE metal housing 2 SIM card Slots Interface Ethernet 10 100 Mbit s USB 2 0 Type A Host 1 digital input 1 digital output Antenna connector SMA 50 Ohm Max Download 100 MBit s Max Upload 50 MBit s S...

Page 12: ...N NB IoT Cable length 5 m Dimensions 82 48 48 mm F0 000 0035 1 wienet antenna 15862V2 PANEL ANT wienet panel antenna Frequency ranges 2G 3G 4G F0 000 0037 6 MPI ETH ADAPTER ACCON NETLINK PRO ACCON NetLink PRO compacts a handy communica tion and programming adapter between PC and S7 controllers F0 000 0031 8 5 3 Basic dimensions of the metal housing Figure 3 Basic dimensions of the metal housing ...

Page 13: ...bly of the router to the switchboard For whip antennas we recommend to observe a distance of 6 cm from cables and metal surfaces on every side according to the next picture due to the elimination of interference while using an external antenna except for the switch board it is necessary to fit a lightening conductor Before mounting a router on sheet steel we recommend using an external antenna Fig...

Page 14: ... plastic and metal DIN rail clip To remove the router from the DIN rail push the router down lightly so the bottom part of the DIN rail clip hitched to the DIN rail gets out of the rail and then pull out the bottom part of the router away from the DIN rail 5 6 User interfaces connectors On the front panel the following is located Name Connector Description PWR 2 pin Connector for the power supply ...

Page 15: ...tly 3 dBm 3 flash per second Signal strength is poor or difference between neighbor cells is less than 3 dBm USR Green Function selected by user OUT Green On Binary output active IN Green On Binary input active ETH Green On Selected 100 MBit s Off Selected 10 MBit s ETH Yellow On Network cable is connected Blinking Data transmission Off Network cable is not connected PORT Green Description by Port...

Page 16: ...nto the router The protection against reversed polarity is lost if the negative pole is grounded The power consumption during receiving is 2 3 W The peak power consumption during data send ing is 5 5 W For correct operation it is necessary that the power source is able to supply a peak cur rent of 1 2 A Circuit example Figure 9 Connection of power supply The positive pole VCC is marked by a red so...

Page 17: ...ng the diversity antenna use the second antenna connector DIV The third connector GPS in the full version of the router is used for additional antenna intended for GPS router supports active GPS antenna On user s request this antenna connector can be modified to WIFI The antenna is connected to screw the antenna connector SMA to SMA connector on the router head See figure below Diversity antenna i...

Page 18: ...rent adjusted APN Access Point Name Supported type of SIM cards Mini SIM 2FF dimensions 25 0 15 0 0 76 mm Changing the SIM card Before handling the SIM card turn off the router and disconnect it from power supply Press the small yellow button to eject the reader holder Insert the SIM card into the reader holder and slide it in the reader see figure below Make sure that the gold contact side of the...

Page 19: ...panel Pin Signal Description Data flow direction 1 TXD Transmit Data positive pole Input Output 2 TXD Transmit Data negative pole Input Output 3 RXD Receive Data positive pole Input Output 4 5 6 RXD Receive Data negative pole Input Output 7 8 Figure 12 Ethernet port Port ETH is not POE Power Over Ethernet compatible Plug Ethernet cable into the RJ45 connector labeled as ETH see the figure below Fi...

Page 20: ...on PORT1 cable 5 6 7 PORT2 The PORT2 is equipped on customer s request with one of the offered expansion ports RS232 RS485 RS422 PORT2 is available only in the Full version of the router Description connection and examples of optional connection ports can be found in separate manuals expansion ports BA000917 see 1 4 Other applicable documents p 5 5 6 8 USB port USB A connector on front panel Pin S...

Page 21: ... input Input 2 GND Signal ground 3 OUT0 Binary output Output Figure 16 I O connector male The user interface I O is designed for processing of binary input signal and to control settings of binary output signal Binary output is not switched to ground by default configuration Maximum load binary output is 30 V 100 mA The constant current supplied by the binary input is 3 mA Connect I O cable into t...

Page 22: ...nfiguration manual BA001039 see 1 4 Other applicable documents p 5 because reset router set configuration to the initial state It is important to distinguish between resetting and rebooting the router Action Router behavior Invoking events Reboot Turn off and then turn on router Disconnect and connect the power Press the reboot button in the web config uration Reset Restore default configuration a...

Page 23: ...ault APN DHCP server starts to assign addresses for devices on the Ethernet port ETH0 Router s behavior can be changed via the web interface This is described in detail in the Configuration manual BA001039 see 1 4 Other applicable documents p 5 The power consumption during receiving is 2 3 W The peak power consumption during data send ing is 5 5 W However values of consumption can be increased if ...

Page 24: ...word default password see label P last 8 digits of CSN h After successfully entering login information the user gains access to the router via his internet browser A detailed description of the router settings via the Web interface can be found in the Configuration manual BA001039 see 1 4 Other applicable documents p 5 NOTICE ...

Page 25: ...et protocol The default IP address of the device is 192 168 1 1 Standard TCP ports are used 22 for the SSH and 23 for the Telnet Please note that access is permitted for users of the admin role only and that the Telnet protocol is disabled by default For a detailed description of SSH and Telnet configuration see the Configuration manual BA001039 see 1 4 Other applicable documents p 5 NOTICE ...

Page 26: ...onsumption Idle GPRS LTE 2 3 W To 3 5 W GPRS transmission To 5 5 W LTE transmission Dimensions 42 76 113 mm DIN 35 mm Weight 280 g Antenna connector 3 SMA 50 Ohm User interfaces ETH USB PORT1 PORT2 Ethernet 10 100 MBit s USB 2 0 type A host Optional RS 232 RS 485 422 ETHERNET M BUS or In put Output CNT 3 Port Switch Optional RS 232 RS 485 422 WIFI M BUS or Input Output CNT 3 Port Switch SD Card Co...

Page 27: ...l 5 6 7 8 standard Supported frequencies B5 850 MHz B8 900 MHz B2 1900 MHz B1 2100 MHz Max power typical 24 dBm GPRS parameters Data throughput max 236 kbps 3GPP rel 99 standard GPRS multi slot class 10 EGPRS multi slot class 10 Coding schemes CS 1 to 4 MCS 1 to 9 Supported frequencies 850 900 1800 1900 MHz Max power typical 26 32 dBm Supported GPRS EDGE power classes GSM 850 CS Class 4 32 dBm EGS...

Page 28: ... device can still detect an in view satellite 98 of the time when in sequential tracking mode Acquisition sensitivity is the lowest GPS signal level for which the device can still detect an in view satellite 50 of the time 7 3 Technical data of processor 32b ARM microprocessor Memory 512 MB DDR SDRAM 16 MB DDR SDRAM FLASH 64 MB MRAM 128 kB M RAM Interface Serial interface RS 232 Ethernet interface...

Page 29: ...he router has to be disabled on NAT Configuration page in the router Also enable Send all remaining incoming packets to default server feature and fill in the IP address of your Web server On the Web server the default gateway has to be the IP ad dress of the router Mobile WAN connection fails Check the signal power Mobile WAN status page If the signal power is weak use a better antenna If the nei...

Page 30: ...ure you have SSH enabled Configuration section Services SSH Then you can connect with any client on port 22 with name and password same as for the Web interface L2TP or IPsec is not establishing Check the System Log page for error messages I switched the router to offline mode by the SMS message but the router is in online mode after reboot SMS messages do not change the router configuration They ...

Page 31: ...overy techniques in order to minimize impact on the environment This product contains high quality materials and components which can be recycled At the end of its life this product MUST NOT be mixed with other commercial waste for disposal The device contains the battery Remove the battery from the device before disposal The battery in the device needs to be disposed apart accordingly Check the t...

Page 32: ...electric com Wieland Electric GmbH Brennerstraße 10 14 D 96052 Bamberg Tel 49 0 951 9324 0 Fax 49 0 951 9324 128 E Mail info wieland electric com http eshop wieland electric com http www wieland electric com Admission Wieland Electric hereby declares that the router narrated in this user s guide fits all basic demands of directive 1999 5 EC R TTE ...

Page 33: ...Wieland Electric GmbH Brennerstraße 10 14 DE 96052 Bamberg Tel 49 951 9324 0 Fax 49 951 9324 198 info wieland electric com www wieland electric com ...