Page 1: ...WH7016C Thermostat Product Manual ...

Page 2: ...hort circuit the user can not modify Terminals 7 and 8 Temperature connection sensor Note The load refers to the heating or cooling equipment on control Electrical performance Temperature measurement range 50 110 Temperature control range 50 110 Temperature measurement error 0 5 Sensor Type NTC 10K 3435 Control accuracy 1 Working voltage AC DC12V Working current 2W Relay contact point current AC 7...

Page 3: ...n the thermostat can be turned off Cooling heating function Cooling Mode When the measured temperature is higher than or equal to the set value hysteresis the relay picks up to start the output When the measured temperature below the set value the relay off and close the output Heating mode When the measured temperature is higher than or equal to the set value the relay off turn off the output Whe...

Page 4: ...oling mode the first power on when the measured value above the set value hysteresis value the machine will not immediately start cooling it needs to set the delay time then the machine can run to start cooling once the interval between two cooling is larger than the delay time the machine immediately starts cooling once the interval between two cooling is less than the delay time the machine must...

Page 5: ...minimum set limit 50 110 50 HS The maximum set limit 50 110 110 CA Temperature calibration 5 5 0 PT Delay time 0 10 1 Minutes fault tips 1 When the sensor disconnected the screen displays and close the heating wire 2 When the sensor detects the temperature is below 50 degrees the screen displays LLL 3 When the sensor detects a temperature higher than 110 degrees the screen displays HHH Caution for...

Reviews: