Page 1: ...OPERATORS MANUAL Reach in Blast Chiller Reach in Blast Chiller Freezer WBC10 WBCF10 WBC20 WBCF20 WBC30 WBCF30 WBC40 WBCF40 WBC50 WBCF50 ...

Page 2: ...ge 3 Ventilation Thermometer Storage Times Page 4 Principles of Operation Page 5 Operations of Blast Chillers Chiller Freezers Page 6 Defrost Page 7 Alarm Warning Levels Page 8 Breakdown Cleaning Gasket Condenser Cleaning Page 9 Gasket Replacement Page 10 Parts Only Warranty Page 11 Customer Satisfaction Questionnaire ...

Page 3: ...s fitted with castors are non adjustable therefore a level platform floor should be provided where the cabinet is to be located On models fitted with adjustable legs levelling may be achieved by adjustment of the bottom section of the legs For marine specification models with flanged feet for deck fixing and bulkhead fixings installation should be carried out by a specialist marine companies For t...

Page 4: ...containers Avoid stacking containers directly on top of one another as this will drastically extend the chilling time and take special care not to block the air ducts Always load the machine before selecting the blast facility Unless it is unavoidable do not open the door of the machine whilst the blast cycle is engaged When loading the cabinet please ensure the load is equally distributed through...

Page 5: ... Chill which is available from Williams Marketing Department 44 1553 817000 Fast temperature reduction is not brought about by placing the food in a very cold cabinet like a deep freeze This would only dry the food badly and would take a very long time to reduce its temperature to the required level increasing the risk to food safety The secret of fast temperature reduction is in delivering the co...

Page 6: ... process each probe s information is displayed for 4 seconds while in the scrolling mode will enable users to move through the data slowly is pressed at any time the cabinet returns to normal store mode Function 5 can be initiated in any operating mode except standby BLAST CHILL OR FREEZE PROGRAMMING Check that the chillers is operating at storage temperature Load the products for chilling freezin...

Page 7: ...nstigated at the end of each blast chill cycle to clear any ice from the evaporator ready for the next cycle During storage mode a defrost will be performed automatically at the factory preset interval of 6 hours If a blast cycle is cancelled the machine will automatically initiate a defrost During a defrost the display windows will indicated the following Following a blast chill cycle An alarm co...

Page 8: ...obe T3 auxiliary probe not applicable T6 Food probe 3 no probe Alarm codes that are displayed are E1 HP LP fault Hi High temperature E2 Over temperature Lo Low temperature E3 Mains failure longer than 3 minutes or Probe over range failure Alarms during Blast Cycles If the blast chill cycle has been terminated as a result of an fault causing an alarm a defrost cycle will automatically be initiated ...

Page 9: ...ards the interior of the cabinet by pushing it in the centre as you twist the support through 90 The shelf support will be released Note the supports are designed to be anti tilt and you may therefore experience some resistance at first which will be overcome with practice When all shelves have been removed remove the racking by lifting up and over the nylon retaining blocks GASKET Clean the gaske...

Page 10: ...and retaining clips Once cleaning or any maintenance is completed replace the unit covers and plug the cabinet in to restart operation EVAPORATOR DRAINLINE Should be inspected periodically to ensure the drain hole is not blocked REPLACING THE GASKET Damaged gaskets are easily replaced To fit a new gasket simply pull out the old gasket and push the new gasket into the channel gasket retainer at the...

Page 11: ......

Page 12: ...ier whose warranty may be different 3 Made to measure modular cold storage is excepted Our responsibility under this warranty shall cease if a Authorised representatives of Williams Refrigeration are denied full and free rights of access to the equipment for inspection at a convenient time b The customer permits persons other than those authorised by Williams Refrigeration to perform or effect rep...

Page 13: ...ood Very Good Excellent How was the service you received Poor Average Good Very Good Excellent Other Comments Name Position Company Address Tel Serial No Thank you for taking the time to complete the questionnaire Please fax your completed form to the Marketing Department on 01553 817111 or send it to the address printed on the back cover of this booklet Data Protection The details you supply will...

Page 14: ...lectromagnetic Compatibility Directive 89 336 EEC Pressure Equipment Directive 97 23 EC Williams Refrigeration declares that all products manufactured by Williams Refrigeration comply with the above directives as they apply to those products and those products are therefore declared to be in conformity with the provisions of the above legislation MING FAI STAINLESS STEEL EQUIPMENT LTD 4A Harringto...