background image

 

Read instructions before operating the machine

Bitte lesen Sie diese Anleitungen, bevor Sie die Maschine in Gebrauch nehmen

MODEL: 

  COUNTRY 

CDT7IA/10080050  

AUSTRALIA 

CDT7IB/10080060  

BRITIAN 

CDT7IE/10080070  

EUROPE 

CDT7IS/10080080  

SWITZERLAND 

Operating Instructions (USA) 
Bedienungsanleitung (GER) 

86038340  04/19/07 
 
PRV NO. 98707 

AF 

CARPET EXTRACTOR 

IPX4

Summary of Contents for Cadet 10080050

Page 1: ...leitungen bevor Sie die Maschine in Gebrauch nehmen MODEL COUNTRY CDT7IA 10080050 AUSTRALIA CDT7IB 10080060 BRITIAN CDT7IE 10080070 EUROPE CDT7IS 10080080 SWITZERLAND Operating Instructions USA Bedienungsanleitung GER 86038340 04 19 07 PRV NO 98707 AF CARPET EXTRACTOR IPX4 ...

Page 2: ...___________________________________ Phone Number _________________________________________________________________________________________ MODEL _______________________________________ DATE OF PURCHASE __________________________ SERIAL NUMBER ______________________________ SALES REPRESENTATIVE _____________________ DEALER NAME ________________________________ OPERATIONS GUIDE NUMBER ______________...

Page 3: ...omponents 3 2ENG Filling the Solution Tank 3 5ENG Machine Operation 3 6ENG Cleaning Procedure 3 9ENG Accessory Tool Usage 3 10ENG MAINTENANCE Periodic Maintenance 4 1ENG Daily Regular Maintenance 4 1ENG Vacuum Motor Replacement 4 2ENG Belt Replacement 4 3ENG Solution Pump Replacement 4 3ENG Machine Troubleshooting 4 4ENG Wiring Diagram 4 5 GROUP PARTS LIST Frame Assembly 5 1 Brush Assembly 5 3 Pum...

Page 4: ... contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the parts illustration PART NO column lists the part number for the part PRV NO reference number QTY column lists the quantity of the part used in that area of the machine DESCRIPTION column is a brief description of the part S...

Page 5: ... service center Do not pull or carry machine by electrical cord use as a handle close a door on cord or pull cord around sharp edges or corners Do not run machine over cord Keep cord away from heated surfaces Do not unplug machine by pulling on cord To unplug grasp the electrical plug not the electrical cord Do not handle the electrical plug or machine with wet hands Do not operate the machine wit...

Page 6: ...r safe operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentially dangerous conditions to the operator or the equipment Read this information carefully Know when these conditions can exist Locate all safety devices on the machine Please take the necessary steps...

Page 7: ...0 04 19 07 2 3ENG NOTE These drawings indicate the location of safety labels on the CDT7 10080230 If at any time the labels become illegible contact your Windsor representative for prompt replacement WARNING DECAL 86242230 PRV NO 500009 ...

Page 8: ...ccessory tool to begin cleaning STEP 3 STEP 4 STEP 1 STEP 2 Use only one of the following acceptable accessory tools 86000000 PRV NO DDH 86031540 PRV NO 39504 86041180 PRV NO ESW 86000050 PRV NO SPW 86000020 PRV NO HT Pull back collar and insert over machine mounted fitting then release collar to lock into place Lift door on front of vacuum shoe and insert 1 inch hose cuff into hole PUMP VACUUM ON...

Page 9: ...I diaphragm style internal bypass SOLUTION CAPACITY 7 gallons 26 5ltr RECOVERY CAPACITY 7 gallons 26 5ltr BRUSH SPEED 1000 rpm GENERAL DIMENSIONS WEIGHT Vacuum shoe 17 43 18 cm cast aluminum with spring loaded down pressure WHEELS 2 10 dia 25 cm wheels by 2 WEIGHT 92lbs 42kg LENGTH 41 104 cm HEIGHT 34 86 36 cm WIDTH 17 5 44 45 cm SOLUTION SPRAY 2 quick change jets POWER CABLE 50 12 7 m 1mm 17 5 44...

Page 10: ...alve to dispense solution to floor through jets Intermittent off and continuous settings 5 Vacuum Motor Switch Turns on vacuum motor 6 Brush Motor Circuit Breaker 4 amp Breaker protecting brush motor 7 Vacuum Motor Circuit Breaker 7 amp Breaker protecting vacuum motor 8 Recovery Dump Hose Facilitates draining dirty cleaning solution 9 Solution Dump Hose Facilitates draining excess cleaning solutio...

Page 11: ...ect various auxiliary 1 1 2 inch cleaning tool vacuum hoses 3 Brush Height Adjustment Used to regulate brush height from storage position to various carpet heights 4 Recovery Tank Used to collect dirty cleaning solution 5 Solution Tank Used to hold cleaning solution 6 Recovery Tank Dome 7 Vacuum Shoe 8 Brush Housing 9 Front Lifting Handle 10 Cleaning Solution Filter 4 5 6 7 8 ...

Page 12: ...CONTROLS COMPONENT LOCATIONS CADET 86038340 04 19 07 3 4ENG 1 Solution Intake Cover 2 Vacuum Intake Cover 3 Float Shut Off 4 Clean Out Opening 5 Pour Spout 6 Lift Handle 2 1 3 4 5 6 6 ...

Page 13: ... tank CHEMICALS Suitable Chemicals Non Compatible Chemicals Alkalis Aldehydes Detergents Aromatic Hydrocarbons Hydroxides SP Butyls Soaps Carbon Tetrachloride Vinegar Clorox Chlorinated Bleaches Chlorinated Hydrocarbons Lysol Methyl Ethel Ketone MEK Perchorethylene perc Phenolics Trichlorethylene D Limonene Product Trademark Names Remove recovery tank Add water Add cleaning chemical Replace recove...

Page 14: ...etting Note For good operation the brush must skim the carpet If circuit breaker trips raise brush to prevent damage to motor or carpet Plug cord into grounded outlet Note Be sure dome is seated on recovery tank and float shut off is installed correctly Turn on both Vacuum and Pump motor switches ON I STEP 1 STEP 2 STEP 3 STEP 4 CORRECT INCORRECT 1 8in 3mm PUMP VACUUM ON ON ...

Page 15: ...in the on position with the thumb and is typically used in small areas where short cleaning passes are made The continuous setting allows the operator to set the switch in the on position with one touch and is typically used in large areas where long cleaning passes are made Lower machine to floor Tip machine back by main handle to move to starting point STEP 5 STEP 6 STEP 7 INTERMITTENT CONTINUOU...

Page 16: ...t drive belt side of machine During operation observe the following The Cadet is equipped with clear internal covers to facilitate operator viewing of dirty solution and vacuum air flow During operation observe the vacuum intake cover Large amounts of water or foam entering the vacuum system can damage the vacuum motor If you notice either condition shut down the machine immediately Empty recovery...

Page 17: ... hose Use a hose with cold water to clean out the recovery tank Also drain solution tank after each use STEP 7 STEP 8 After cleaning turn off all controls return brush to storage position and carefully unplug machine STEP 6 STEP 5 Use right side of machine for cleaning against walls RECOVERY DRAIN SOLUTION DRAIN OFF OFF OFF ...

Page 18: ...ource 1 Empty unused cleaning solution from the solution tank 2 Inspect and clean filter screen in solution tank 3 Flush pumping system with 4 or 7 liters of clean hot water 4 After each use rinse tank with fresh water Periodically inspect the recovery tank and decontaminate if necessary using a Hospital Grade Virucide or a 1 10 bleach to water solution Waste water should be disposed of properly 5...

Page 19: ...using will damage motor if brushes are allowed to wear away completely If armature commutator is not concentric extremely pitted or grooved the motor will need to be replaced or sent to a qualified service center to restore vac performance Periodically check the length of the carbon brushes Replace both carbon brushes when either is less than 3 8 long Note Place stop in groove 3 8 End Cap Carbon B...

Page 20: ... process to install belt ONLY QUALIFIED MAINTENANCE PERSONNEL ARE TO PERFORM THE FOLLOWING REPAIRS SOLUTION PUMP REPLACEMENT 1 Turn off all switches and unplug the machine 2 Remove recovery tank 3 Remove the 2 screws that fasten the solution tank to the frame and tilt tank back to expose the inside of the frame 4 Remove solution hoses from fittings in pump 5 Remove the 2 screws that fasten the pum...

Page 21: ...hoe 2 Dome gasket defective or missing 3 Vacuum hose cracked or hose cuff loose 4 Recovery tank full float ball stuck in the up position 1 Remove debris from vac shoe 2 Replace as necessary 3 Replace or repair as necessary 4 Turn off vac motor Drain and rinse recovery tank Poor Or No Water Flow Carpet Is Streaky 1 Main pump switch off 2 Jets clogged or missing 3 Solution filter clogged 4 Faulty so...

Page 22: ... 19 07 4 5ENG 86268750 PRV NO 88567 86268750 PRV NO 88567 86268750 PRV NO 88567 86268750 PRV NO 88567 86268350 PRV NO 88270 86003650 PRV NO 34362 86001240 PRV NO 14020 86268900 PRV NO 88655 86268900 PRV NO 88655 86004480 PRV NO 41353 ...

Page 23: ...NOTES CADET 86038340 04 19 07 4 6ENG ...

Reviews: