Mounting of BS02/X3 cylinder into the FSB window handle
Conditions (before assembly):
- Before the assembly remove the window handle from the window frame.
- Dismount the handle component from the handle bottom part.
- If necessary, dismount existing cylinder (remove M5 countersunk screw,
turn the cam to 6:00 h with the key, then remove cylinder).
• On cylinder: Remove the cam retainer (2) and the cam (1) from cylinder
BS02/X3 by loosening the screw (3).
• Insert BS02/X3 cylinder (5) into the bottom part of the handle and tighten
by hand with M5 countersunk screw (4) (see picture 1)
• Slide the cam (1) on the cylinder BS02/X3 (see picture 2 left side)
• Use a countersunk screw (3) to fix the cam retainer on the cylinder by
hand (see picture 2 right side)
• Perform function test of the component:
- Lock the half cylinder with an authorised key.
- Lock and unlock the window handle.
Aug. Winkhaus GmbH & Co. KG · Hessenweg 9 · 48157 Münster · T +49 251 - 49 08 - 0 · F +49 251- 49 08 -145
www.winkhaus.de
Mounting Instructions BS02/X3
Assembly, disassembly and battery replacement
Pic. 1: Insert half cylinder BS02/X3
Pic. 2: Slide on the locking cam and
fix cam retainer with screw
Locking cam
Cam retainer
Half cylinder BS02/X3
Screw M3 x 12
Countersunk screw M5 x 30
1
5
3
2
4
1
2
3
4
5
4
5
1
2
3